Peer Review History

Original SubmissionSeptember 22, 2022
Decision Letter - Gantumur Battogtokh, Editor

PONE-D-22-26320Rapid Generation of Homogenous Tumor Spheroid Microtissues in a Scaffold-Free Platform for High-Throughput Screening of a Novel Combination NanomedicinePLOS ONE

Dear Dr. Seyed Abbas Shojaosadati,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript by Jan 08 2023 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Gantumur Battogtokh

Academic Editor

PLOS ONE

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at 

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. Thank you for stating in your Funding Statement: 

"This study was financially supported by Tarbiat Modares University (TMU) and Iran National Science Foundation (INSF)."

Please provide an amended statement that declares *all* the funding or sources of support (whether external or internal to your organization) received during this study, as detailed online in our guide for authors at http://journals.plos.org/plosone/s/submit-now.  Please also include the statement “There was no additional external funding received for this study.” in your updated Funding Statement. 

Please include your amended Funding Statement within your cover letter. We will change the online submission form on your behalf.

3. In your Data Availability statement, you have not specified where the minimal data set underlying the results described in your manuscript can be found. PLOS defines a study's minimal data set as the underlying data used to reach the conclusions drawn in the manuscript and any additional data required to replicate the reported study findings in their entirety. All PLOS journals require that the minimal data set be made fully available. For more information about our data policy, please see http://journals.plos.org/plosone/s/data-availability.

Upon re-submitting your revised manuscript, please upload your study’s minimal underlying data set as either Supporting Information files or to a stable, public repository and include the relevant URLs, DOIs, or accession numbers within your revised cover letter. For a list of acceptable repositories, please see http://journals.plos.org/plosone/s/data-availability#loc-recommended-repositories. Any potentially identifying patient information must be fully anonymized.

Important: If there are ethical or legal restrictions to sharing your data publicly, please explain these restrictions in detail. Please see our guidelines for more information on what we consider unacceptable restrictions to publicly sharing data: http://journals.plos.org/plosone/s/data-availability#loc-unacceptable-data-access-restrictions. Note that it is not acceptable for the authors to be the sole named individuals responsible for ensuring data access.

We will update your Data Availability statement to reflect the information you provide in your cover letter.

4. We note that you have included the phrase “data not shown” in your manuscript. Unfortunately, this does not meet our data sharing requirements. PLOS does not permit references to inaccessible data. We require that authors provide all relevant data within the paper, Supporting Information files, or in an acceptable, public repository. Please add a citation to support this phrase or upload the data that corresponds with these findings to a stable repository (such as Figshare or Dryad) and provide and URLs, DOIs, or accession numbers that may be used to access these data. Or, if the data are not a core part of the research being presented in your study, we ask that you remove the phrase that refers to these data.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Partly

Reviewer #3: Yes

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: The authors presented a study on the screening of nanomedicine on tumor spheroids.

They constructed the adhesive-free concave surface and loaded the assembled nanodrugs for testing tumor inhibition efficiencies at varied component ratios and delivery methods. They addressed on the surface treatment, drug synthesis and drug intake quantitation process and tested the drug efficacy in 3D spheroids. However, issues listed below should be settled before being accepted.

1. Page 16, line 1. Typos in “MDA-MB-23”. The missing number should be implemented.

2. The figures should be combined together to include more information in one figure. And, the quality (font consistency, color matching, boldness, arrows, resolution) should all be improved profoundly. There must be neat ways of exhibition for Figure 3, 4, 12.

3. Some of the figures are supposed to move into supp. Figures.

Reviewer #2: In this work, the authors show how three compounds encapsulated in nanoparticles are used to test drug efficacy in 2D cell cultures and 3D spheroids obtained from a breast cancer cell line.

Overall, the paper lacks novelty and clarity in few aspects of the proposed work. Therefore, I do not recommend publication in its present form. Below are my comments:

1) The introduction is rather lengthy and it would benefit from a clear summarised statement with regard to what aspect(s) of in vitro preclinical assays this work is addressing.

2) It is unclear what the original aspects of this work are. A statement of novelty should be inserted. Is this about the NP formulation? Running NP-based assays in low adhesion plates using spheroids is not novel, so maybe is the results obtained? These points should be clearly addressed to remove ambiguities.

3) The authors state the importance of using physiologically relevant models of cancer to bridge the gap with in vivo models, but here a single cell line is used which is far from any TME complex composition. So one may question the suitability of the model used (for example due to the lack of ECM, fibroblasts or other cell types in an avascular tumour tissue).

4) The bottom image in the table on page 10 is blurry and it is unclear what is representing. The table itself is redundant and the points have already being discussed in the introduction.

5) Very importantly, what is the advantage of using the proposed NPs if the drug efficiency was higher for free drugs (i.e. without NPs)? What is the evidence of “enhanced penetration and combinational therapy effect were practically translated into the tumour spheroid cytotoxicity after a 48 h treatment” as stated in section 3.7? I cannot find this in the paper.

6) It is well established that 2D cell monolayer respond differently to 3D cultures, but the model used here is not similar to any in vivo tumours.

7) Regarding the wound healing assays, why was this not done with free drugs as well as a comparison? The conclusion obtained from this assay are not meaningful in my opinion without a comparison with free drugs.

8) Where is the evidence of deep NP penetration? It is stated that NPs could not penetrate tight spheroids! So this is a disadvantage with respect to free drugs.

9) The statement about HTS with plates and models is not justified. The authors present a screen done in low adhesion 96 well plates. What is new about this? What is different from any other HTS assays in plates (e.g. 96 or even higher 384 well plates)?

10) Figure 9 is just an estimate schematic, to show proliferative, quiescent and necrotic zones, but specific dyes should be used to show the different phenotypes in a spheroid.

Reviewer #3: The work has good design and contains valuable information on “Rapid Generation of Homogenous Tumor Spheroid Microtissues in a Scaffold-Free Platform for High-Throughput Screening of a Novel Combination Nanomedicine”. I am sure that the paper will give further insights into new studies related to tumor spheroids for the screening of nanomedicines. However, I suggested the paper acceptance after major corrections.

1. Introduction part of the manuscript is too long. Please re-write and reduce the size of the introduction to almost half.

2. The methodology part is unclear. This seems like the author skipped many important information.

3. Why did the author use PVA coating instead of using low attachment plates for generating 2D and 3D spheroids?

4. There were no clear information about 3D spheroid formation in the same methodology part.

5. Did author use EGF and FGF growth factors in the growth media of tumor spheroids??

6. The number of cells used for spheroids formation is too high for 96 well plates. The author should provide the proper justification with citations for using that much high number of cells.

7. Cell density used per well for scratch wound healing assay is also very high as author used 24 wells plate. Please provide references considering during the experiment performed.

8. In many places the author cited the mechanism such as drug induces tumor cell apoptosis via various apoptosis signaling pathways such as NF-kB, PI3K/Akt, and STAT3. This is totally irrelevant in the whole manuscript as the author did not do anything related to mechanism throughout his study.

9. Figure 2B: I would like to see the complete crop image of Particle Size Distribution Graph mentioning the size of particles.

10. I do not find the Zeta Potential Graph of particle. I would recommend please including the Zeta potential graph as well as PDI values.

11. There are no scale bars in figure 10, figure 11, and figure 13. Please provide the scale bars for all these images.

12. I suggested language checking of the manuscript before publication because some mistakes are looked in the manuscript.

13. Please include some important references during revising the manuscript suggested below:

https://doi.org/10.1016/j.fct.2019.01.018

https://doi.org/10.1016/j.mtchem.2021.100618

https://doi.org/10.1016/j.msec.2019.110285

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: Yes: Michele Zagnoni

Reviewer #3: No

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 1

The questions and comments received from the editor and reviewers are answered and addressed meticulously in the attached file entitled "Response to Reviewers".

Attachments
Attachment
Submitted filename: Response to Reviewers.docx
Decision Letter - Gantumur Battogtokh, Editor

Rapid generation of homogenous tumor spheroid microtissues in a scaffold-free platform for high-throughput screening of a novel combination nanomedicine

PONE-D-22-26320R1

Dear Dr. Seyed Abbas Shojaosadati,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Gantumur Battogtokh

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Formally Accepted
Acceptance Letter - Gantumur Battogtokh, Editor

PONE-D-22-26320R1

Rapid generation of homogenous tumor spheroid microtissues in a scaffold-free platform for high-throughput screening of a novel combination nanomedicine

Dear Dr. Shojaosadati:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Gantumur Battogtokh

Academic Editor

PLOS ONE

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .