Peer Review History
| Original SubmissionApril 21, 2022 |
|---|
|
PONE-D-22-11731The Validity and Reliability of Vertical Oscillation Measured by the INCUS NOVA Wearable Device for Running.PLOS ONE Dear Dr. Smith, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. A sincere apologies to the authors on the delayed review process. I had a total of 14 reviewer rejections with a single reviewer feedback. I have made a decision on this manuscript based on the feedback of that reviewer and also provided mine below. Please submit your revised manuscript by Oct 09 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Bernard X W Liew Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Please include your full ethics statement in the ‘Methods’ section of your manuscript file. In your statement, please include the full name of the IRB or ethics committee who approved or waived your study, as well as whether or not you obtained informed written or verbal consent. If consent was waived for your study, please include this information in your statement as well. 3. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. 4. Thank you for stating the following in the Competing Interests section: “I have read the journal's policy and the authors of this manuscript have the following competing interests: The INCUS NOVA wearable device used in the research article is a license product of INCUS Performance Ltd. CPS, EF, LW, EF, DP, and HL were employees of INCUS Performance Ltd. at the time the research was completed.” Please confirm that this does not alter your adherence to all PLOS ONE policies on sharing data and materials, by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests). If there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. Please include your updated Competing Interests statement in your cover letter; we will change the online submission form on your behalf. Additional Editor Comments: Comments 1. Please state the hypotheses at the end of the Introduction 2. How did you ensure time synchronisation of all devices? If not, what mechanism was performed to ensure variables from the same time-instance were compared across devices 3. Each subject had 5 running speeds. Apparently you combined the observations of all subjects and speeds and performed ICC. Have I misinterpreted this? If you have done it, it is incorrect, given that a standard ICC requires individual observations to be independent. Once you have repeated measures, there is variation within each subject that is not accounted for. 4. please explicitly state the bonferroni correction. 5. provide confidence interval for estimates. 6. I am unsure why a comparison between IMU devices are needed. If the aim is to compare which IMU devices is the best, you simply need to compare it with a benchmark. Provide a 95% confidence interval of the error with the benchmark, and that should suffice. 7. I think the authors need to think about is the differences in reliability/validity of each device confounded by different locations? Is it a device issue or a location issue, or likely a mixture of both? [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Thank you for the opportunity to review this manuscript. The manuscript's objectives were to determine the validity and reliability of the INCUS NOVA device compared to certain wearable devices (Garmin Running Dynamics Pod, Garmin HR Monitor, and Stride Running Pod) for measuring vertical oscillation in comparison to 2d video measurements. The results indicate that the INCUS NOVA is an acceptable device for measuring vertical oscillation and are comparable to other devices on the market, with some smaller overestimations and underestimations. I would like to commend the authors for a paper that was clear, well-written, and had all the necessary information for a validation study. The findings of this study may only apply to those using the INCUS NOVA (and the manufacturers for making claims about the device), but the methods are also well presented to allow future research to replicate the details for a validation study. My specific comments are listed below: Line 47: Since you mention that wearable devices provide feedback with "a variety of physiological and biomechanical information", it would be good to include some physiological metrics on top of speed and cadence. OR since your paper is primarily focused on biomechanics, you can exclude physiology and just focus on biomechanics. Line 56: Some examples of visual and auditory feedback would help the reader better understand your claim. Line 60: It should be inertial measurement unit. Lines 75-80: I think the objective statement can flow a little better from the introduction. This paper is clearly aimed towards validating the INCUS NOVA, yet on lines 71-72, you mentioned that the validity and reliability of VO for RDP and Stryd have yet to be validated as well. I recommend either broadening the objective to include the validation of these other devices, or have a smoother transition into the objective that focuses only on INCUS. Line 105 (and throughout): VMCS is not a standard abbreviation and is confusing. Since you don't use it often, I recommend writing out the full term. Lines 263-264: I agree that, depending on the device, caution should be taken when interpreting the values. I recommend adding in the discussion what some potential consequences are with overestimating and underestimating VO in terms of performance and injury. Figures: All of these figures need to be improved, in my opinion. They are very low quality and the plots don't even have axes. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Christian Clermont ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
PONE-D-22-11731R1The Validity and Reliability of Wearable Devices for the Measurement of Vertical Oscillation for Running.PLOS ONE Dear Dr. Smith, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Nov 24 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Bernard X W Liew Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments: There are some minor points to be corrected prior to acceptance. I do not think the corrections to my prior comments were addressed adequately. 1. Hypothesis. Can you please state a hypothesis in the form of which method would you think is the best, based on prior research or theory. A directional hypothesis. 2. Please stated the corrected alpha when stating bonferroni correction - e.g. 0.05/5 3. Can you explicitly mention the term time synchronisation ins the paragraph starting with lin 147? E.g. time normalisation was achieved by..... [Note: HTML markup is below. Please do not edit.] [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 2 |
|
PONE-D-22-11731R2The Validity and Reliability of Wearable Devices for the Measurement of Vertical Oscillation for Running.PLOS ONE Dear Dr. Smith, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Dec 02 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Bernard X W Liew Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments: Dear authors, Before I can accept, there is a mistake in your response. For the Bonferroni correction, you mentioned " the probability values for the paired T-tests were Bonferroni corrected, therefore multiplied by the number of comparisons (i.e. p*10)." If the alpha is 0.05, and it is 0.5, than the correction makes things more lenient. It should be divide. I hope this was a typographical mistake rather than a statistical mistake. Can you clarify? Regards, Bernard [Note: HTML markup is below. Please do not edit.] [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 3 |
|
The Validity and Reliability of Wearable Devices for the Measurement of Vertical Oscillation for Running. PONE-D-22-11731R3 Dear Dr. Smith, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Bernard X W Liew Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .