Peer Review History

Original SubmissionNovember 10, 2021
Decision Letter - Pradeep Kumar, Editor

PONE-D-21-35811Diagnostic performance of the AID Line Probe Assay in the detection of Mycobacterium tuberculosis and drug resistance in Romanian patients with presumed TBPLOS ONE

Dear Dr. Ibraim

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript by May 6, 2022. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Pradeep Kumar, Ph.D.

Academic Editor

PLOS ONE

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at 

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. Please include a complete copy of PLOS’ questionnaire on inclusivity in global research in your revised manuscript. Our policy for research in this area aims to improve transparency in the reporting of research performed outside of researchers’ own country or community. The policy applies to researchers who have travelled to a different country to conduct research, research with Indigenous populations or their lands, and research on cultural artefacts. The questionnaire can also be requested at the journal’s discretion for any other submissions, even if these conditions are not met.  Please find more information on the policy and a link to download a blank copy of the questionnaire here: https://journals.plos.org/plosone/s/best-practices-in-research-reporting. Please upload a completed version of your questionnaire as Supporting Information when you resubmit your manuscript

Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Partly

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: No

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: Development of rapid drug resistance for Tb is an urgent need in order to control Tb transmission globally. The authors have sought to evaluate the performance on a new LPA, using p-DST and sequencing as reference standard. The reviewer agrees with conclusions of the authors AID test has moderate sensitivity and high specificity for Tb diagnostic, but due to high proportion of non-evaluable tests would not be able to conclude the assay has high drug resistance sensitivity (the confidence intervals are extremely wide).

Line 134: reference missing

Table 2 requires revision. It is not very intuitive. It is not clear what is the comparative assay for “All participants” section. I wonder if it is better to separate the table into table 2A where the comparative assay is phenotypic drug susceptibility assay and then table 2B where the comparative assay will be smear microscopy.

Line 231: is non-evaluable term coined by the manufacturer and commonly used within diagnostic practices? Would “indeterminate” be a better alternative? It would certainly help the reader if non-evaluable is defined in the methods section. Moving the AID assay reader rules from supplementary section to main portion of the methods section is needed to understand the interpretation of the assay output. In the methods section the authors describe “invalid” results. Is it same as non-evaluable?

Line 237: is it table 4?

Line 241: inhA -16?

Table 5: is not very intuitive as well. It seems like the authors are trying to determine whether the non-evaluable results is associated with smear status. It would help to discuss these numbers of non-evaluable results in the results section and move the table to the supplementary section. Additionally, if the authors could comment on whether they investigated for an association with a lot number of the kits, instruments, or buffer.

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 1

Dear Editor and Reviewers!

We are very grateful for the thorough and thoughtful way in which this manuscript has been reviewed. We are pleased that we were given the chance to submit a revised version of our manuscript. We hope that we have correctly addressed all comments and that the changes have improved the manuscript significantly.

Please find a point-by-point response to the helpful comments below:

Comment #1 of Reviewer #1: Development of rapid drug resistance for Tb is an urgent need in order to control Tb transmission globally. The authors have sought to evaluate the performance on a new LPA, using p-DST and sequencing as reference standard. The reviewer agrees with conclusions of the authors AID test has moderate sensitivity and high specificity for Tb diagnostic, but due to high proportion of non-evaluable tests would not be able to conclude the assay has high drug resistance sensitivity (the confidence intervals are extremely wide).

Authors` reply to Comment #1 of Reviewer #1: Thank you for the thorough evaluation of our manuscript and your guidance. We are pleased that the reviewer agrees with our main conclusions regarding the diagnostic accuracy of the AID test with respect to the detection of M. tuberculosis and the prediction of anti-tuberculosis drug-resistance.

Comment #2 of Reviewer #1: Line 134: missing reference

Authors` reply to Comment #2 of Reviewer #1: Thank you very much for noticing this mistake. The WHO technical guidelines to which we are referring to is reference number “15” as it was already indicated at the end of the sentence (line 136, in manuscript with track-changes). Thus, we have removed “(REF)” from the manuscript (line 136, in manuscript with track-changes).

Comment #3 of reviewer #1: Table 2 requires revision. It is not very intuitive. It is not clear what is the comparative assay for “All participants” section. I wonder if it is better to separate the table into table 2A where the comparative assay is phenotypic drug susceptibility assay and then table 2B where the comparative assay will be smear microscopy.

Authors` reply to Comment #3 of Reviewer #1: We agree with this comment and revised table 2 (incl. titles and legends) accordingly and separated it as suggested in 2A and 2B. As tables are different content-wise and from layout perspective, we would offer to change the numbering to table 2 and table 3, accordingly, and also that from all downstream tables. In table 2B we now calculate the sensitivity of AID-modules stratified by smear-microscopy status, in order to convey that sensitivity of the AID assay is greatly varying according to positive versus negative smear-microscopy status of the respective participant. We think that it is not appropriate in our study to use smear-microscopy as comparative assay, as smear microscopy is an insufficient reference standard with much lower sensitivity compared to culture methods, which would result in false positive AID-test results (i.e. in the 16 smear-negative but culture positive culture-confirmed TB patients) and may confuse some readers of the manuscript.

Comment #4 of reviewer #1: Line 231: is non-evaluable term coined by the manufacturer and commonly used within diagnostic practices? Would “indeterminate” be a better alternative? It would certainly help the reader if non-evaluable is defined in the methods section. Moving the AID assay reader rules from supplementary section to main portion of the methods section is needed to understand the interpretation of the assay output. In the methods section the authors describe “invalid” results. Is it same as non-evaluable?

Authors` reply to Comment #4 of Reviewer #1: We are grateful for this comment as it reflects previous internal discussion we had in our team. As the manufacturer does not account for missing or incomplete reaction zones in their manual, we searched the literature and found that for the analysis and reporting of other line probe test results (mainly Hain assays) the terms valid and invalid were majorly used (sometimes also the term indeterminate). Therefore we replaced the term non-evaluable by the term invalid. In addition, we provide a description of the term “invalid” in the methods section, lines 117-119, in manuscript version with trach-changes included.

Comment #5 of reviewer #1: Line 237: is it table 4?

Authors` reply to Comment #5 of Reviewer #1: Thanks a lot for spotting this mistake, we changed it to table 4 (line 253)

Comment #6 of reviewer #1: Line 241: inhA-16?

Authors` reply to Comment #6 of Reviewer #1: Thank you very much, your comment is correct. We added the dash accordingly (line 257).

Comment #7 of reviewer #1: Line Table 5: is not very intuitive as well. It seems like the authors are trying to determine whether the non-evaluable results is associated with smear status. It would help to discuss these numbers of non-evaluable results in the results section and move the table to the supplementary section. Additionally, if the authors could comment on whether they investigated for an association with a lot number of the kits, instruments, or buffer.

Authors` reply to Comment #7 of Reviewer #1: We agree with moving the table to the supplement. Further, we described the patterns of invalid results in different sub-groups in the result section, including modifications of the text in order to ensure that the message is understandable and clear, even without simultaneous viewing of the table. Additionally, we amended the discussion on invalid test results, including a sentence on the association with kit numbers, buffers or PCR-protocol (lines 367-370).

Attachments
Attachment
Submitted filename: Response to Reviewers.docx
Decision Letter - Pradeep Kumar, Editor

Diagnostic performance of the AID Line Probe Assay in the detection of Mycobacterium tuberculosis and drug resistance in Romanian patients with presumed TB

PONE-D-21-35811R1

Dear Dr. Rachow,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Pradeep Kumar, Ph.D.

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Formally Accepted
Acceptance Letter - Pradeep Kumar, Editor

PONE-D-21-35811R1

Diagnostic performance of the AID Line Probe Assay in the detection of Mycobacterium tuberculosis and drug resistance in Romanian patients with presumed TB

Dear Dr. Rachow:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Pradeep Kumar

Academic Editor

PLOS ONE

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .