PONE-D-21-39449Laser light sources for Photobiomodulation: The role of power and beam characterization in treatment accuracy and reliabilityPLOS ONE

Dear Dr. Guirro,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

The reviewers were generally positive, but requested a number of minor revisions

Please submit your revised manuscript by Mar 25 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Michael R Hamblin

Academic Editor

PLOS ONE

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at 

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf.

2. Please clarify in your Methods section how permission was sought to access the equipment, and who provided permission.

3. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Yes

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: I thank the Authors for their evaluation of laser photobiomodulation device parameters and detailed discussion thereof.

This manuscript is well-written and comprehensive, and the methodology is reported in sufficient detail to allow reproduction.

The analyses addressed only devices manufactured and used in Brazil, however, the conclusions drawn and recommendations presented have broader applicability, being relevant to devices in use throughout the rest of the world.

I have only a minor alteration and some corrections to suggest:

1. That the study was limited to devices produced and used in Brazil should be stated in the Abstract, perhaps as follows (second sentence, first paragraph): "The aim of this study was to evaluate the average and maximum power and to describe the beam diameter of different low-power laser photobiomodulation devices in clinical use in Brazil.".

2. Line 203 (pg 4), "The average power, fell within 90% to 110%...": Please delete the comma after "power".

3. Line 216 (pg 4), "...as well as for 904 nm (Figure 3C) is highlighted.": Please change "is" to ", are".

4. 2nd para, pg 8, "Here we can calculate the beam radios with the probe in contact...": Please change "radios" to "radius".

Thank you.

Reviewer #2: TITLE: Analysis of low-level laser transmission at wavelengths 660, 830 and 904 nm in biological tissue samples

Page 2 Line 5

The authors report that “Differences in beam

55 diameter of between 38% and 543% of the nominal values”

COMMENT most laser is used for Photobiomodulation are semiconductor/dialysers which typically have elliptical beams in which case they do not have a diameter (strictly speaking they have two diameters)

SUGGESTION describe the differences in the beam area rather than diameter

Page 3 Line 104

The authors report that "Photobiomodulation parameters associated with its effectiveness are not only fluence and light penetration depth but also full optical properties, such as refractive index, absorption, scattering coefficients, beam diameter, and stable output power." also line 115 “However, the equipment manufacturers have predefined some base fluence values without considering the individual characteristics of each subject”

line 116 this context, if the power and the beam diameter are different than expected due to a faulty function of the equipment, the quality of the treatment will be affected

COMMENT the authors mixed photobiomodulation parameters and topics of light propagation into one sentence

light penetration depth refractive index, absorption, scattering coefficients are are topics of light propagation.

I think it is beyond the scope of this paper tooth tackle matters of individual characteristics of each patient and a stick to the key objective which is “ evaluate and describe the

119 laser beam diameter and the average power in different devices in clinical use in Brazil.”

SUGGESTION remove references to light propogation in the patient as follows

114 [2] Enwemeka reports that trained professionals can only control the physical parameters of the laser to be used for each

115 pathology, given its individuality.

116 if the

117 power and the beam diameter are different than expected due to a faulty function of the equipment, the

118 quality of the treatment will be affected. Thus, the objective of this study was to evaluate and describe the

119 laser beam diameter and the average power in different devices in clinical use in Brazil.

I added the word “only” on line 114

Page 4 Line 139-141

The authors report that "The devices with wavelengths in the red spectrum were analyzed

140 during one minute of sequential irradiation and the infrared ones during one and three minutes to observe

141 possible emitted power changes"

COMMENT why did you choose longer treatment times for the infrared lasers ?

SUGGESTION state the reasons why you choose longer treatment times for the infrared lasers

Page 11 Line (no line reference on manuscript)

The authors report that "Their results indicate that as the beam width increases, there is also an increase in the penetration depth. Furthermore, a method in which the beamwidth changes from 1 to 40 mm were proposed by their group, demonstrating that beam diameters between 1 mm and 5 mm have a notable increase in penetration depth"

COMMENT I downloaded the reference paper (Barbosa 2020 Analysis of low-level laser transmission at wavelengths 660, 830 and 904 nm in biological tissue samples. PMID 32516626). The referenced paper does not conclude that as beam width increases, there is also an increase in the penetration depth. It seems both intuativly wrong and my own punpublished experiemnts on pit tissue find the opposite.

SUGGESTION remove all references to increased beam leads to increased penetration.

Page 12 Line (no line reference on manuscript)

The authors report that "the real fluence emitted by the equipment has not been measured"

COMMENT equipment does not emit “fluence”, it emits photons at a wavelength, photon per second equal power, when divided by a beam area on the pataint equals irradiance, and when a doctor, nurse or therapist applies that irradiance for a certain amount of time then a certain fluence has been delivered.

SUGGESTION "the real power or irradiance emitted by the equipment has not been measured"

Page 12 CONCLUSION

I agree with this conclusion. The Photobiomodulation literature is plagued by the problems described.

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: Yes: Peter A. Jenkins, M.B.A.

Reviewer #2: Yes: James D Carroll

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 1

- Reviewer #1

Comment: That the study was limited to devices produced and used in Brazil should be stated in the Abstract, perhaps as follows (second sentence, first paragraph): "The aim of this study was to evaluate the average and maximum power and to describe the beam diameter of different low-power laser photobiomodulation devices in clinical use in Brazil.".

Answer: We thank the reviewer. This suggestion has been accepted and highlighted in the manuscript.

Comment: Line 203 (pg 4), "The average power, fell within 90% to 110%...": Please delete the comma after "power".

Answer: The suggestion was accepted and highlighted in the manuscript. Thank you.

Comment: Line 216 (pg 4), "...as well as for 904 nm (Figure 3C) is highlighted.": Please change "is" to ", are".

Answer: The suggestion was accepted and highlighted in the manuscript. Thank you.

Comment: 2nd para, pg 8, "Here we can calculate the beam radios with the probe in contact...": Please change "radios" to "radius".

Answer: The suggestion was accepted and highlighted in the manuscript. Thank you.

- Reviewer #2

Comment: Page 2 Line 5 - The authors report that "Differences in beam diameter of between 38% and 543% of the nominal values" - COMMENT most laser is used for Photobiomodulation are semiconductor/dialysers which typically have elliptical beams in which case they do not have a diameter (strictly speaking they have two diameters) - SUGGESTION describe the differences in the beam area rather than diameter.

Answer: The suggestion was considered. However, we cannot state the difference in the area since the nominal definition in the Brazilian devices is given in general averages. Thus, as our data is presented and made available, only one diameter was measured and compared. So, unfortunately, changing to an area would produce non-existent data. Also, we would like to point out that in the session Methods/ Beam diameter evaluation, we explain how this value was reached. Furthermore, we emphasize that we have inserted this as a limitation of the study. We are open to further considerations.

Comment: Page 3 Line 104 - The authors report that "Photobiomodulation parameters associated with its effectiveness are not only fluence and light penetration depth but also full optical properties, such as refractive index, absorption, scattering coefficients, beam diameter, and stable output power." also line 115 "However, the equipment manufacturers have predefined some base fluence values without considering the individual characteristics of each subject". Line 116 this context, if the power and the beam diameter are different than expected due to a faulty function of the equipment, the quality of the treatment will be affected - COMMENT the authors mixed photobiomodulation parameters and topics of light propagation into one sentence light penetration depth refractive index, absorption, scattering coefficients are topics of light propagation. I think it is beyond the scope of this paper tooth tackle matters of individual characteristics of each patient and a stick to the key objective which is "evaluate and describe the laser beam diameter and the average power in different devices in clinical use in Brazil." - SUGGESTION remove references to light propogation in the patient as follows.

Answer: The suggestion was accepted, and the sentence had been deleted from the manuscript. Thank you.

Comment: Enwemeka reports that trained professionals can only control the physical parameters of the laser to be used for each pathology, given its individuality [...] if the power and the beam diameter are different than expected due to a faulty function of the equipment, the quality of the treatment will be affected. Thus, the objective of this study was to evaluate and describe the laser beam diameter and the average power in different devices in clinical use in Brazil. - I added the word "only" on line 114.

Answer: The suggestion was accepted and highlighted in the manuscript. Thank you.

Comment: Page 4 Line 139-141 - The authors report that "The devices with wavelengths in the red spectrum were analyzed during one minute of sequential irradiation and the infrared ones during one and three minutes to observe possible emitted power changes" - COMMENT why did you choose longer treatment times for the infrared lasers? - SUGGESTION state the reasons why you choose longer treatment times for the infrared lasers.

Answer: The suggestion was discussed, resubmitted, and highlighted in the manuscript. Thank you.

Comment: Page 11 Line (no line reference on manuscript) - The authors report that "Their results indicate that as the beam width increases, there is also an increase in the penetration depth. Furthermore, a method in which the beamwidth changes from 1 to 40 mm were proposed by their group, demonstrating that beam diameters between 1 mm and 5 mm have a notable increase in penetration depth" - COMMENT I downloaded the reference paper (Barbosa 2020 Analysis of low-level laser transmission at wavelengths 660, 830 and 904 nm in biological tissue samples. PMID 32516626). The referenced paper does not conclude that as beam width increases, there is also an increase in the penetration depth. It seems both intuativly wrong and my own punpublished experiemnts on pit tissue find the opposite. - SUGGESTION remove all references to increased beam leads to increased penetration.

Answer: We agree that the citation was misplaced. The central idea was in front of the wavelength in biological tissues as presented by Barbosa 2020 and the wavelength of the beam according to the extrapolation of Ash 2017. The text was reorganized for the correct interpretation. Thank you for the suggestion.

Comment: Page 12 Line (no line reference on manuscript) - The authors report that "the real fluence emitted by the equipment has not been measured" - COMMENT equipment does not emit "fluence", it emits photons at a wavelength, photon per second equal power, when divided by a beam area on the pataint equals irradiance, and when a doctor, nurse or therapist applies that irradiance for a certain amount of time then a certain fluence has been delivered. - SUGGESTION "the real power or irradiance emitted by the equipment has not been measured".

Answer: The suggestion was accepted and highlighted in the manuscript. Thank you.

Comment: Page 12 CONCLUSION - I agree with this conclusion. The Photobiomodulation literature is plagued by the problems described.

Answer: Thank you for your appreciation.

Attachments
Attachment
Submitted filename: Response to Reviewers.docx
Decision Letter - Michael R Hamblin, Editor

Laser light sources for Photobiomodulation: The role of power and beam characterization in treatment accuracy and reliability

PONE-D-21-39449R1

Dear Dr. Guirro,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Michael R Hamblin

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Formally Accepted
Acceptance Letter - Michael R Hamblin, Editor

PONE-D-21-39449R1

Laser light sources for Photobiomodulation: The role of power and beam characterization in treatment accuracy and reliability

Dear Dr. Guirro:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff