Peer Review History

Original SubmissionSeptember 9, 2021
Decision Letter - Robertas Damaševičius, Editor

PONE-D-21-28729Deep Learning Model for Fully Automated Detection of Abnormal Breast Tissues from ThermogramsPLOS ONE

Dear Dr. A. Mohamed,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Specifically, we authors need to improve the description of their methodology and the presentation of the results, which must include statistical analysis.

Please submit your revised manuscript by Nov 13 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Robertas Damaševičius

Academic Editor

PLOS ONE

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at 

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. We suggest you thoroughly copyedit your manuscript for language usage, spelling, and grammar. If you do not know anyone who can help you do this, you may wish to consider employing a professional scientific editing service. 

Whilst you may use any professional scientific editing service of your choice, PLOS has partnered with both American Journal Experts (AJE) and Editage to provide discounted services to PLOS authors. Both organizations have experience helping authors meet PLOS guidelines and can provide language editing, translation, manuscript formatting, and figure formatting to ensure your manuscript meets our submission guidelines. To take advantage of our partnership with AJE, visit the AJE website (http://learn.aje.com/plos/) for a 15% discount off AJE services. To take advantage of our partnership with Editage, visit the Editage website (www.editage.com) and enter referral code PLOSEDIT for a 15% discount off Editage services.  If the PLOS editorial team finds any language issues in text that either AJE or Editage has edited, the service provider will re-edit the text for free.

Upon resubmission, please provide the following:

The name of the colleague or the details of the professional service that edited your manuscript

A copy of your manuscript showing your changes by either highlighting them or using track changes (uploaded as a *supporting information* file)

A clean copy of the edited manuscript (uploaded as the new *manuscript* file)”

3. We note that Figure 1 in your submission contain copyrighted images. All PLOS content is published under the Creative Commons Attribution License (CC BY 4.0), which means that the manuscript, images, and Supporting Information files will be freely available online, and any third party is permitted to access, download, copy, distribute, and use these materials in any way, even commercially, with proper attribution. For more information, see our copyright guidelines: http://journals.plos.org/plosone/s/licenses-and-copyright.

We require you to either (1) present written permission from the copyright holder to publish these figures specifically under the CC BY 4.0 license, or (2) remove the figures from your submission:

a. You may seek permission from the original copyright holder of Figure 1 to publish the content specifically under the CC BY 4.0 license. 

We recommend that you contact the original copyright holder with the Content Permission Form (http://journals.plos.org/plosone/s/file?id=7c09/content-permission-form.pdf) and the following text:

“I request permission for the open-access journal PLOS ONE to publish XXX under the Creative Commons Attribution License (CCAL) CC BY 4.0 (http://creativecommons.org/licenses/by/4.0/). Please be aware that this license allows unrestricted use and distribution, even commercially, by third parties. Please reply and provide explicit written permission to publish XXX under a CC BY license and complete the attached form.”

Please upload the completed Content Permission Form or other proof of granted permissions as an "Other" file with your submission. 

In the figure caption of the copyrighted figure, please include the following text: “Reprinted from [ref] under a CC BY license, with permission from [name of publisher], original copyright [original copyright year].”

b. If you are unable to obtain permission from the original copyright holder to publish these figures under the CC BY 4.0 license or if the copyright holder’s requirements are incompatible with the CC BY 4.0 license, please either i) remove the figure or ii) supply a replacement figure that complies with the CC BY 4.0 license. Please check copyright information on all replacement figures and update the figure caption with source information. If applicable, please specify in the figure caption text when a figure is similar but not identical to the original image and is therefore for illustrative purposes only.

Additional Editor Comments:

Revise the article following the reviewer comments.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Partly

Reviewer #2: Yes

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: No

Reviewer #2: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: No

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: The manuscript sounds technically poor, I have following concerns should be addressed before any decision. The paper currently need revision.

1. The existing literature should be classified and systematically reviewed, instead of being independently introduced one-by-one.

2. The abstract is too general and not prepared objectively. It should briefly highlight the paper's novelty as what is the main problem, how has it been resolved and where the novelty lies?

3. The 'conclusions' are a key component of the paper. It should complement the 'abstract' and normally used by experts to value the paper's engineering content. In general, it should sum up the most important outcomes of the paper. It should simply provide critical facts and figures achieved in this paper for supporting the claims.

4. For better readability, the authors may expand the abbreviations at every first occurrence.

5. The author should provide only relevant information related to this paper and reserve more space for the proposed framework.

6. However, the author should compare the proposed algorithm with other recent works or provide a discussion. Otherwise, it's hard for the reader to identify the novelty and contribution of this work.

7. The descriptions given in this proposed scheme are not sufficient that this manuscript only adopted a variety of existing methods to complete the experiment where there are no strong hypothesis and methodical theoretical arguments. Therefore, the reviewer considers that this paper needs more works.

8. Key contribution and novelty has not been detailed in manuscript. Please include it in the introduction section

9. What are the limitations of the related works

10. Are there any limitations of this carried out study?

11. How to select and optimize the user-defined parameters in the proposed model?

12. There are quite a few abbreviations are used in the manuscript. It is suggested to use a table to host all the frequently used abbreviations with their descriptions to improve the readability

13. Explain the evaluation metrics and justify why those evaluation metrics are used?

14. Some sentences are too long to follow, it is suggested that to break them down into short but meaningful ones to make the manuscript readable.

15. The title is pretty deceptive and does not address the problem completely.

16. Every time a method/formula is used for something, it needs to be justified by either (a) prior work showing the superiority of this method, or (b) by your experiments showing its advantage over prior work methods - comparison is needed, or (c) formal proof of optimality. Please consider more prior works.

17. The data is not described. Proper data description should contain the number of data items, number of parameters, distribution analysis of parameters, and of the target parameter itself for classification.

18. The related works section is very short and no benefits from it. I suggest increasing the number of studies and add a new discussion there to show the advantage. Following studies can be considered

a. Breast-Cancer Detection using Thermal Images with Marine-Predators-Algorithm Selected Features.

b. Dilated Semantic Segmentation for Breast Ultrasonic Lesion Detection Using Parallel Feature Fusion.

c. Machine-Learning-Scheme to Detect Choroidal-Neovascularization in Retinal OCT Image

d.

19. Use Anova test to record the significant difference between performance of the proposed and existing methods.

Reviewer #2: Dear Authors,

This work employs U-Net model to extract and evaluate the abnormal section from the Breast Thermal Images.

I request you to consider the following suggestions:

1. The image size is fixed as 228x228, but, the initial input dimension in UNet is depicted as 572x572. Please check and correct.

2. The quality of the image is to be improved in every image cases.

3. What is the need for extracting the breast section, please justify. Further, include, how the CNN scheme is trained to segment the image (a clear discription is needed).

4. The image dimension, such as test image, Ground truth and segmented image is not looks like 228x228. Further in this database, the Ground Truth is not available. Please discuss, how the GT is generated (Hope, the test images are from :http://visual.ic.uff.br/dmi/).

5. Please improve the reference section by considering few more related works.

(Please refer, the following research works:

a. Breast-Cancer Detection using Thermal Images with Marine-Predators-Algorithm Selected Features

b. An Examination System to Classify the Breast Thermal Images into Early/Acute DCIS Class

c. A hybrid framework to evaluate breast abnormality using infrared thermal images

6. I request you to compare the outcome of the proposed scheme with another results existing in the literature.

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 1

Original Manuscript ID: PONE-D-21-28729

Original Article Title: “Deep Learning Model for Fully Automated Detection of Abnormal Breast Tissues from Thermograms “

Dear Editor,

Thank you for allowing a resubmission of a revised version of the manuscript, with an opportunity to address the reviewers’ comments.

We are uploading (a) our point-by-point response to the comments (below) (response to reviewers), (b) an updated manuscript with yellow highlighting indicating changes, and (c) a clean updated manuscript without highlights

Best regards,

Authors,

Reviewer#1, Concern # 1: The existing literature should be classified and systematically reviewed, instead of being independently introduced one-by-one.

The literature is classified systematically as recommended

Reviewer#1, Concern # 2: The abstract is too general and not prepared objectively. It should briefly highlight the paper's novelty as what is the main problem, how has it been resolved and where the novelty lies?

The abstract is edited as recommended.

Reviewer#1, Concern # 3: The 'conclusions' are a key component of the paper. It should complement the 'abstract' and normally used by experts to value the paper's engineering content. In general, it should sum up the most important outcomes of the paper. It should simply provide critical facts and figures achieved in this paper for supporting the claims.

A conclusion section is added to the manuscript with your instructions.

Reviewer#1, Concern # 4: For better readability, the authors may expand the abbreviations at every first occurrence.

The manuscript is edited with abbreviation definition at every first occurrence.

Reviewer#1, Concern # 5: The author should provide only relevant information related to this paper and reserve more space for the proposed framework.

Information that is not related to this paper were removed. See the update in the Revised Manuscript with Track Changes page 16.

Reviewer#1, Concern # 6: However, the author should compare the proposed algorithm with other recent works or provide a discussion. Otherwise, it's hard for the reader to identify the novelty and contribution of this work.

A comparison between the proposed algorithm and other works is already exist in table 10. Also, we update this table with recent works. See the update in the Revised Manuscript with Track Changes page 18-19. From this table, we can note that the dataset used by our proposed system is large compared with the dataset of some related work. Also, our system extracts the breast area automatically by using U-Net network, but some related work doesn't used segmentation method and other extract it manually. In addition, the evaluation metric of our proposed system is better than related work. Furthermore, Statistical analysis by ANOVA test (see table 9) indicates the viability of the proposed system. In addition, the proposed system is domain-independent, so it has the ability to be applied to various computer vision tasks.

Reviewer#1, Concern # 7: The descriptions given in this proposed scheme are not sufficient that this manuscript only adopted a variety of existing methods to complete the experiment where there are no strong hypothesis and methodical theoretical arguments. Therefore, the reviewer considers that this paper needs more works.

To automate and improve the accuracy of thermography systems, we designed a deep learning-based system which integrates U-Net network and a proposed deep learning model. The proposed system is a combination two important methods: U-Net network and a two-class CNN-based deep learning model. First, U-Net is a convolutional network architecture which proved very strong in biomedical segmentation and very fast compared with other methods [29]. U-Net is used in our system to automatically extract and isolate the breast area from other parts of the body which act as noise in the detection system. Second, the two-class CNN-based deep learning model is trained from scratch to extract more characteristics from the dataset that is helpful in training the network and improve the efficiency of the classification process. The novelty of the proposed system lays in using U-Net network for automating the segmentation process and building a deep learning model which use the output of U-Net to classify the given thermogram. The combination between U-Net and our proposed deep learning model proved to be effective as it achieved accuracy= 99.33%, sensitivity=100% and specificity=98.67%

Reviewer#1, Concern # 8: Key contribution and novelty has not been detailed in manuscript. Please include it in the introduction section.

We add the main contribution of this paper in the introduction section. To quickly and easily check this update, it is in page 4 of Revised Manuscript with Track Changes, it is also copied below:

The main contribution of this paper is as following:

1-Extracting and isolating the breast area automatically from other parts of thermal images by using CNN (U-Net).

2- Proposing a deep learning model for the classification of normal and abnormal breast tissues from thermograms

3-Evaluating the performance of the proposed model using accuracy, sensitivity and specificity.

4-Comparing the proposed model with state-of art methods.

Reviewer#1, Concern # 9: What are the limitations of the related works?

Limitations of the related work are added in the literature review section.

Reviewer#1, Concern # 10: Are there any limitations of this carried out study?

The computation time of the segmentation process is high due to the limitation of the PC capabilities used in this study.

The proposed deep learning model for classification has a bad behavior when the learning rate is greater than 3.0 e−03

Reviewer#1, Concern # 11: How to select and optimize the user-defined parameters in the proposed model?

There is no general rule for it. Selecting the optimum number of the user-defined parameters is dependent on the performance of the model and the result of the evaluation metrics.

Reviewer#1, Concern # 12: There are quite a few abbreviations are used in the manuscript. It is suggested to use a table to host all the frequently used abbreviations with their descriptions to improve the readability

Thank you for your comment. We add a table of abbreviation to the manuscript. To quickly and easily check this table, it is copied below:

Abbreviation Definition

CNN Convolutional Neural Networks

CAD Computer-Aided Detection

ROI Region of Interest

EHMM Extended Hidden Markov Models

NS Neutrosophic Sets

F-FCM Fast Fuzzy C-Mean

SVM Support Vector Machine

KNN K-Nearest Neighbor

NN Naïve Bayes

PCA Principal Component Analysis

DNN Deep Neural Network

DWNN Deep-Wavelet Neural Networks

RELU Rectified Linear Activation Function

ADAM Adaptive Moment Estimation

SGDM Stochastic Gradient Descent with Momentum

RMSprop Root Mean Square propagation

TP True Positive

TN True Negative

FP False Positive

FN False Negative

GLCM Gray Level Co-occurrence Matrices

HOG Histogram of Oriented Gradients

n normal

ab abnormal

Reviewer#1, Concern # 13: Explain the evaluation metrics and justify why those evaluation metrics are used?

We edit evaluation the deep learning model section as following. To quickly and easily check this update in the Revised Manuscript with Track Changes page 11. Also, it is copied below:

Classification Metrics evaluate the performance of the model and measure how good or bad the classification is.

Accuracy: represents how many instances are completely classified correctly. It is calculated by dividing the total number of predictions by the number of right predictions. It is calculated by Eq. (3)

Accuracy=(T_P+T_N)/(T_P+T_N+F_P+F_N ) (3)

Sensitivity: is calculated based on how many patients have the disease are correctly estimated. It is calculated by Eq. (4)

Sensitivity=T_P/(T_P+F_N ) (4)

Specificity: is calculated based on how many patients do not have the disease are predicted right. It is calculated by Eq. (5)

Specificity=T_N/(T_N+F_P ) (5)

•True Positive (TP) refers to a positive-class sample that has been successfully classified by a model.

• False Positive (FP) refers to a sample that should have been classed as negative but was instead classified as positive.

• True Negative (TN) refers to a negative-class sample that has been successfully classified by a model.

• False Negative (FN) refers to a sample that should have been classed as positive but was instead classified as negative.

The accuracy metric indicates how many of the model's predictions were right. However, if the dataset is unbalanced, a model's high accuracy rate does not guarantee its ability to differentiate distinct classes equally. In specifically, in the classification of medical images, it is necessary to develop a model with the ability be applied to all classes. In cases, sensitivity and specificity should be used to provide information about the performance of the model. Sensitivity measures the percentage of patient have the disease that the proposed model correctly predicted. Specificity measures the percentage of patient do not have the disease and correctly estimated by the proposed model. These two evaluation metrics measure the ability of the model to decrease FN and FP predictions.

Reviewer#1, Concern # 14: Some sentences are too long to follow, it is suggested that to break them down into short but meaningful ones to make the manuscript readable

We try to break some sentences down into short as much as we can.

Reviewer#1, Concern # 15: The title is pretty deceptive and does not address the problem completely.

The title of the article is changed into " Deep Learning Model for Fully Automated Breast Cancer Detection System from Thermograms"

Reviewer#1, Concern # 16: Every time a method/formula is used for something, it needs to be justified by either (a) prior work showing the superiority of this method, or (b) by your experiments showing its advantage over prior work methods - comparison is needed, or (c) formal proof of optimality. Please consider more prior works.

The limitations of the prior work are added to the literature review section. To quickly and easily check update in the Revised Manuscript with Track Changes page 7. Also, it is copied below:

From the discussed related work above, it could be remarked that the prior work has some limitations such as:

(1) some related work used a small number of the dataset as in [6, 20].

(2) some related work did not consider segmentation of the breast area before classification such as in [27] or extract the breast area manually such as in [20, 21].

(3) some segmentation models such as in [1] removed parts of the breast.

(4) some work has been evaluated by only calculating the accuracy metric only such as in [29]. However, the high accuracy rate of a model does not ensure its ability to distinguish different classes equally if the dataset is unbalanced [39].

Therefore, a fully automated breast cancer detection system from thermograms is needed and should be evaluated by not only the accuracy but also the most related metrics such as sensitivity and specificity.

Also, more recent prior works are added to the literature review section and compared with the proposed method in table 10.

Reviewer#1, Concern # 17: The data is not described. Proper data description should contain the number of data items, number of parameters, distribution analysis of parameters, and of the target parameter itself for classification.

A data description table is added to the manuscript as table1. To quickly and easily check this table, it is copied below:

Dataset categories Dimension Training Validation Testing Total

Normal 640x480 350 75 75 500

Abnormal 640x480 350 75 75 500

Reviewer#1, Concern # 18: The related works section is very short and no benefits from it. I suggest increasing the number of studies and add a new discussion there to show the advantage. Following studies can be considered

a. Breast-Cancer Detection using Thermal Images with Marine-Predators-Algorithm Selected Features.

b. Dilated Semantic Segmentation for Breast Ultrasonic Lesion Detection Using Parallel Feature Fusion.

c. Machine-Learning-Scheme to Detect Choroidal-Neovascularization in Retinal OCT Image

The recommended studies are cited in the manuscript as following:

a�23- Rajinikanth V, Kadry S, Taniar D, Damaševičius R and Rauf H T. Breast-Cancer Detection using Thermal Images with Marine-Predators-Algorithm Selected Features. In: 2021 Seventh International conference on Bio Signals, Images, and Instrumentation (ICBSII); Chennai, India. 2021.

b�30- Irfan R, Almazroi A, Rauf H, Damaševiˇcius R, Nasr E and Abdelgawad A. Dilated Semantic Segmentation for Breast UltrasonicLesion Detection Using Parallel Feature Fusion. Diagnostics.2021; 11: 1212.

c� 36- Rajinikanth V, Kadry S, Damaševičius R, Taniar D and Rauf H T. Machine-Learning-Scheme to Detect Choroidal-Neovascularization in Retinal OCT Image. In: 2021 Seventh International conference on Bio Signals, Images, and Instrumentation (ICBSII); Chennai, India. 2021.

Reviewer#1, Concern #19: Use Anova test to record the significant difference between performance of the proposed and existing methods.

We add statistical analysis section to the manuscript. To quickly and easily check this section in the Revised Manuscript with Track Changes page 16. Also, it is copied below:

4.7 Statistical Analysis

To analyze the evaluation of the proposed system statistically, we perform the analysis of variance (ANOVA) test, where the proposed system is compared with ResNet18, GoogleNet and VGG16 networks. The result of the ANOVA test is shown in table 9. To reject the null hypothesis, the p-value in the ANOVA test should be less than 0.05. According to Table 9, the p−value is less than 0.05. So, the null hypothesis was rejected by the results of ANOVA test.

Results of the ANOVA test of the proposed model and CNN models

Model P-value

ResNet18 0.0423

GoogleNet 0.0173

VGG16 0.0023

Reviewer#2, Concern # 1: The image size is fixed as 228x228, but, the initial input dimension in UNet is depicted as 572x572. Please check and correct.

Thank you for comment. But, if you define the network, then you can change the input dimension in the input layer to your desired one.

Reviewer#2, Concern # 2: The quality of the image is to be improved in every image cases.

Thank you for your comment. The quality of the image is improved

Reviewer#2, Concern # 3: What is the need for extracting the breast section, please justify. Further, include, how the CNN scheme is trained to segment the image (a clear discription is needed).

We add the answer of this question in Breast area segmentation using deep learning (CNN) section. To quickly and easily check this section in the Revised Manuscript with Track Changes page 8. Also, it is copied below:

The thermal image contains unnecessary areas as neck, shoulder, chess and other parts of the body which acts as noise during the training in CNN models. The aim of extracting the breast section is removing unwanted regions and using the areas destined to have cancer as the input of the CNN model for training and testing.

In U-Net, the initial series of convolutional layers are combined with max pooling layers to decrease the resolution of the input image. Then, these layers are followed by a series of convolutional layers combined with upsampling operators in order, so the resolution of the input image is increased. Combining these two paths produces a U-shaped graph that can used to perform image segmentation. For breast area segmentation with U-Net, Adaptive Moment Estimation (ADAM) method was used as optimized algorithm with number of epochs = 30. In addition, the training process was started with initial learning rate = 1.0e−3. The learning rate used a piecewise schedule and dropped by a factor of 0.3 every 10 epochs to allow the network to train quickly with a higher initial learning rate. The network trained with an 8-batch size to save memory.

Reviewer#2, Concern # 4: The image dimension, such as test image, Ground truth and segmented image is not looks like 228x228. Further in this database, the Ground Truth is not available. Please discuss, how the GT is generated (Hope, the test images are from:http://visual.ic.uff.br/dmi/).

Thank you for your comment. All images are resized to 228x228. Ground Truth images is not available for general in the site, we get it by personal communication. The test images are from the site.

Reviewer#2, Concern # 5 Please improve the reference section by considering few more related works.(Please refer, the following research works:

a. Breast-Cancer Detection using Thermal Images with Marine-Predators-Algorithm Selected Features

b. An Examination System to Classify the Breast Thermal Images into Early/Acute DCIS Class

c. A hybrid framework to evaluate breast abnormality using infrared thermal images

The recommended studies are cited in the manuscript as following:

a->23- Rajinikanth V, Kadry S, Taniar D, Damaševičius R and Rauf H T. Breast-Cancer Detection using Thermal Images with Marine-Predators-Algorithm Selected Features. In: 2021 Seventh International conference on Bio Signals, Images, and Instrumentation (ICBSII); Chennai, India. 2021.

b->20- Dey N, Rajinikanth V and Hassanien A. E. An Examination System to Classify the Breast Thermal Images into Early/Acute DCIS Class. In: Proceedings of International Conference on Data Science and Applications; Singapore. 2021.

c->10- Fernandes S, Kadry S and Rajinikanth V. A hybrid framework to evaluate breast abnormality using infrared thermal images. IEEE Consumer Electronics Magazine. 2019; 8: 31-36.

Reviewer#2, Concern # 6 I request you to compare the outcome of the proposed scheme with another results existing in the literature.

Thank you for your comment. This comparison is already existing in Table 10. Also, we compare the proposed scheme with the related work considered in comment 5 in the same table.

Attachments
Attachment
Submitted filename: Response to Reviewers.docx
Decision Letter - Robertas Damaševičius, Editor

PONE-D-21-28729R1Deep Learning Model for Fully Automated Breast Cancer Detection System from ThermogramsPLOS ONE

Dear Dr. A. Mohamed,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

 Specifically, you need to address these concerns in the revised version:

- Improve the quality of all figures before submitting final version.

- Improve Fig. 10. The data is not discernable. Range Y-axis to [80,100]. Add the units of measurement (percentages).

- Include the data availability statement and the acknowledgement for ". " ext-link-type="uri" xlink:type="simple">http://visual.ic.uff.br/dmi/". 

Please submit your revised manuscript by Jan 07 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-emailutm_source=authorlettersutm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Robertas Damaševičius

Academic Editor

PLOS ONE

Journal Requirements:

Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

Additional Editor Comments:

Improve the quality of all figures before submitting final version.

Improve Fig. 10. The data is not discernable. Range Y-axis to [80,100]. Add the units of measurement (percentages).

Include the data availability statement and the acknowledgement for "" ext-link-type="uri" xlink:type="simple">http://visual.ic.uff.br/dmi/".

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.

Reviewer #1: All comments have been addressed

Reviewer #2: All comments have been addressed

********** 

2. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Yes

********** 

3. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: N/A

Reviewer #2: Yes

********** 

4. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

********** 

5. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

********** 

6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: The paper is well revised an can be accepted. However, please improve the quality of all figures before submitting final version.

Reviewer #2: Dear Authors,

The revised version of the paper is good.

If possible, include the data availability of include the acknowledgement for "" ext-link-type="uri" xlink:type="simple">http://visual.ic.uff.br/dmi/".

Thank you.

********** 

7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 2

Original Manuscript ID: PONE-D-21-28729R1

Original Article Title: “Deep Learning Model for Fully Automated Breast Cancer Detection System from Thermograms “

To: PLOS ONE

Re: Response to reviewers

Dear Editor,

Thank you for allowing a resubmission of a revised version of the manuscript, with an opportunity to address the reviewers’ comments.

We are uploading (a) our point-by-point response to the comments (below) (response to reviewers), (b) an updated manuscript with yellow highlighting indicating changes, and (c) a clean updated manuscript without highlights

Best regards,

Authors,

Improve the quality of all figures before submitting final version.

Thank you for your comment. The quality of figures is improved

Improve Fig. 10. The data is not discernable. Range Y-axis to [80,100]. Add the units of measurement (percentages).

Thank you for your comment. Figure 10 is improved as per your instruction.

Include the data availability statement and the acknowledgement for "http://visual.ic.uff.br/dmi/".

Thank you for your comment. The acknowledgement for (http://visual.ic.uff.br/dmi) is added to the paper. To quickly and easily check this, it is in page 20 of Revised Manuscript with Track Changes, it is also copied below:

Acknowledgement

The authors would like to thank the Department of Computer Science and the Hospital of the Federal University Fluminense, Niterói, Brazil, for providing DMR-IR benchmark database which is accessible through an online user-friendly interface (http://visual.ic.uff.br/dmi) and used for experiments.

Attachments
Attachment
Submitted filename: Response to Reviewers.docx
Decision Letter - Robertas Damaševičius, Editor

Deep Learning Model for Fully Automated Breast Cancer Detection System from Thermograms

PONE-D-21-28729R2

Dear Dr. Gaber,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Robertas Damaševičius

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Formally Accepted
Acceptance Letter - Robertas Damaševičius, Editor

PONE-D-21-28729R2

Deep Learning Model for Fully Automated Breast Cancer Detection System from Thermograms

Dear Dr. Gaber:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Professor Robertas Damaševičius

Academic Editor

PLOS ONE