Peer Review History
| Original SubmissionSeptember 14, 2021 |
|---|
|
PONE-D-21-29815Empirical Modeling of the Percent Depth Dose for Megavoltage Photon BeamsPLOS ONE Dear Dr. Wu, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Nov 19 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Suhairul Hashim, PhD Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match. When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section 3. Thank you for stating the following in the Acknowledgments Section of your manuscript: "This work was supported by the Funding: Key R&D plan of Science and Technology Program of Gansu Province, China. (18YF1FH153)." We note that you have provided funding information that is not currently declared in your Funding Statement. However, funding information should not appear in the Acknowledgments section or other areas of your manuscript. We will only publish funding information present in the Funding Statement section of the online submission form. Please remove any funding-related text from the manuscript and let us know how you would like to update your Funding Statement. Currently, your Funding Statement reads as follows: "This work was supported by the Funding: Key R&D plan of Science and Technology Program of Gansu Province, China. (18YF1FH153)." Please include your amended statements within your cover letter; we will change the online submission form on your behalf. 4. In your Data Availability statement, you have not specified where the minimal data set underlying the results described in your manuscript can be found. PLOS defines a study's minimal data set as the underlying data used to reach the conclusions drawn in the manuscript and any additional data required to replicate the reported study findings in their entirety. All PLOS journals require that the minimal data set be made fully available. For more information about our data policy, please see http://journals.plos.org/plosone/s/data-availability. "Upon re-submitting your revised manuscript, please upload your study’s minimal underlying data set as either Supporting Information files or to a stable, public repository and include the relevant URLs, DOIs, or accession numbers within your revised cover letter. For a list of acceptable repositories, please see http://journals.plos.org/plosone/s/data-availability#loc-recommended-repositories. Any potentially identifying patient information must be fully anonymized. Important: If there are ethical or legal restrictions to sharing your data publicly, please explain these restrictions in detail. Please see our guidelines for more information on what we consider unacceptable restrictions to publicly sharing data: http://journals.plos.org/plosone/s/data-availability#loc-unacceptable-data-access-restrictions. Note that it is not acceptable for the authors to be the sole named individuals responsible for ensuring data access. We will update your Data Availability statement to reflect the information you provide in your cover letter. 5. PLOS requires an ORCID iD for the corresponding author in Editorial Manager on papers submitted after December 6th, 2016. Please ensure that you have an ORCID iD and that it is validated in Editorial Manager. To do this, go to ‘Update my Information’ (in the upper left-hand corner of the main menu), and click on the Fetch/Validate link next to the ORCID field. This will take you to the ORCID site and allow you to create a new iD or authenticate a pre-existing iD in Editorial Manager. Please see the following video for instructions on linking an ORCID iD to your Editorial Manager account: https://www.youtube.com/watch?v=_xcclfuvtxQ Additional Editor Comments: Please address the following concerns by the reviewers to improvise the current manuscript. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: No ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: No Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: This manuscript reports the development of an empirical method to model the high-energy photon beam percent depth dose (PDD) curve. It is an interesting and potentially beneficial for generating physical parameters used for monitor unit checking in radiation therapy. The accuracy of the mathematical formulation produced is very impressive. The manuscript in general is well written. The issue with the manuscript however, is with regard to the formatting and to a lesser extent, the language used. The authors should be more critical with the use of acronyms, and font formatting. For example: • The acronym PDD should be used after it has been defined when it first appeared in the manuscript. • Letter ‘c’ for Sc should be subscripted. ‘Sc’ should be used instead of ‘collimator scatter’ after it has been defined. • Scalar quantity ‘n’ should be italised. Some of the results are presented in the ‘Discussion’ section, which should go under the ‘Results’ section. More discussions on the methods and comparison with other methods/studies are desirable. The manuscript can also be benefited with proofreading exercise to polish up the language. Some other specific comments as follow: Abstract: Page 3, line 54-55. Please acronymise percentage depth dose. Please check throughout the manuscript. Page 3, line 57. Remove ‘collimator scatter’. Sc has been defined earlier. Please check throughout the manuscript. Page 4, line 73. Insert ‘to’ between ‘sizes’ and ‘within’. Page 4, line 77. Add ‘setting’ after ‘clinical’. Page 4, line 77. Please subscript the letter ‘c’ in Sc. Check throughout manuscript. Introduction: Page 6, line 100. Do not capitalise letter ‘m’ in measurement. Page 6, line 103. Change ‘on’ to ‘of’ Page 6 and 7, line 108-119. The authors presented the physics and a number of physical parameters of high energy x-ray which can be found in common radiation physics textbook, which I strongly feel is unnecessary. The authors should instead provide and explain the problem statement/study background or brief literature review of similar study, leading to the aims/objectives of the manuscript. Page 7, line 127-133. The detailed explanation on the mathematical formula is not required here, as it is provided in the method. I suggest to just include the objective(s) of the current study, and its importance. Method: Page 9, line 159. Change ‘Percent depth curve measurement’ to ‘Percent depth dose measurement’ Page 9, Line 163. Superscript number ‘3’ on cm3. Page 10, line 181 to 183. Please clarify the statement ‘This was performed by giving each film a priming dose of 2 Gy, to homogenize the film density using WHICH facility with a dose of 1 Gy at the photon energy of 6 MV’. I don’t understand what is mean by priming the film to 2 Gy, with a dose of 1 Gy? Page 10, line 190. Please specify the version and manufacturer of the software used. Page 10, line 191. Gafchromic film is specified as GAF film in some places, and back to Gafchromic at some places. Please be consistent. The explanation of measurement using Gafchromic film in my opinion, is excessive. The method used for calibrating the film is widely published and the authors can just cite the reference(s), instead of explaining the procedures in great detail. Results: Page 14, line 246-247. It was stated that the measurement using ion chamber coincide with the film measurement. Please provide quantitative values on the agreement. Page 14, line 249. Change ‘at the commissioning’ to ‘during commissioning’. Page 15-16, Figure 1(a)-(d). Despite the excellent agreement between the fitting and measurement, it is imperative to provide the values of goodness of fit (or other quantitate deviation measurement) as a quantitative measure on the fitting performance. Page 17, line 305-309. The expression of Sc should be provided in the methods section. Is ‘FS’ the dimension of field size? This should be stated. Page 18, caption for Figure 2. It was stated that ‘the Sc of photon energy 6 MV (a) and 10 MV 321 (b) can be expressed perfectly by using the parameters n and μ’. I disagree to that because albeit from a reasonably good fit, it is not perfect. There are some slight disagreements at certain field sizes. Page 19, Table 2. I noted the deviations for 6 MV are in general larger than 10 MV. Any explanations for this? Discussion: Some of the results presented here should go under the ‘Results’ section. For instance, page 21, lines Page 21, lines 383-390. Page 24, line 440. Change ‘interest’ to ‘interesting’. Page 24, line 440-442. It was stated that ‘It is very interest that a weaker variation can be seen when the upper jaw and lower jaw collimator setting was reversed’. Any plausible reason/explanation for this? Some tables here (Figure 3 and 4) are results and should go under the results section. More discussion on the utility of the empiral mathematical formula is desirable. Are there any similar empirical methods/mathematical formula reported in the literature? What are the benefits of this method for generating physical parameters for MU checking? What is the future work/recommendations as I believe more work is required to verified the accuracy/feasibility of using such formula in clinical setting? Reviewer #2: Title: Empirical Modeling of the Percent Depth Dose for Megavoltage Photon Beams Manuscript number: PONE-D-21-29815 General comments: This paper describes and empirical method to model the PDD of the high-energy photon beam using a mathematical – buildup-tail function. The study was interesting because the proposed mathematical model could be useful to predict the collimator scatter factor, Sc for PDDs. Please clarify if the measured PDD in Fig 1a-d, were PDD from published literature or from ion chamber measurements. If they were from published data, how did the author managed to acquire such detail of individual measurement points? There are numerous language and grammatical errors throughout the manuscript, unnecessary capitalization at random places, subscripts for Sc etc should be carefully pick-up and corrected by the authors. Specific comments: Introduction – Could the authors present the background and the need for this study? Because, typically PDDs and Sc are measured from the actual beam, because the beams are different for every linac, and depending on the detector used to measure it. Line 100 – measurement – do not capitalize “M” Line 149 and many other places – Sc - to make sure the c is subscripted Line 153 – four photon energies Line 159 – Percent depth dose curve Line 163 – please specify the company, state and country of the PTW. The volume is cm3. Line 182 – What is the reason to prime the film for 2Gy? Was it 1Gy or 2Gy? Please clarify? If the films are primed with 1-2 Gy, then, how would that affect the calibration curves? Where is the 0 Gy point? Line 186 – Why is the gafchromic calibration curve called a Hurter-Diffield calibration curve? There were description of the use of gaf film – but I fail to see the purpose of the film measurements, since the authors only used the ion chamber measured data. Line 200 – 214 – Please explain the linac used to measure the Sc. Line 222 – no need to capitalize percent depth dose Line 237 – four photon energies Line 240 – please write in full sentence. Figure 1a – d – The two modeled and published PDD appears to match very well, but, at the region of dose buildup and end of tail, the dose descrepencies are obvious. Perhaps an additional graph on the error/difference between the 2 curves can be added to the figures to show the differences? Figure 2 a and b – again, what are the errors of the measured values, i.e. error bars? Where were these values obtained from? Table 1 – These parameters are specific for the 4 PDDs that the authors had modeled on. Please discuss how these values are going to be applicable for any PDDs? Line 306 – no need to capitalize buildup Table 2 – shows the error between the measured and predicted Sc. Perhaps, displaying this in a graph format would be better and summarize the average, SD or max deviation at what field size. Unless the numerical value has any value for any PDD or field sizes of the reader. Line 359 – no need to capitalize buildup Interesting explanation of the equations. However, one of the limitation of the model, correct me if I am wrong, is unable to predict the dose at the surface, at d = 0 cm and the discrepancy of the model at the dose buildup region could be quite big. Can the authors comment on the errors at these regions? Line 427 – no figure 3 caption. Table 3 – should this be in the results? ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
Empirical Modeling of the Percent Depth Dose for Megavoltage Photon Beams PONE-D-21-29815R1 Dear Dr. Wu, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Suhairul Hashim, PhD Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors have addressed my earlier concerns. I can now recommend to accept the paper for publication. Reviewer #2: The authors has adequately address the questions and the manuscript is much improved. I recommend for the acceptance of the manuscript. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No |
| Formally Accepted |
|
PONE-D-21-29815R1 Empirical Modeling of the Percent Depth Dose for Megavoltage Photon Beams Dear Dr. Wu: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Suhairul Hashim Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .