Peer Review History
| Original SubmissionNovember 11, 2021 |
|---|
|
PONE-D-21-35895Molecular dynamics simulations reveal the selectivity mechanism of structurally similar agonists to TLR7 and TLR8PLOS ONE Dear Dr. Jinxia Nancy Deng, Thank you for submitting your manuscript to PLOS ONE. After careful consideration based on the reviewers comments, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands and must undergo a major revision for further consideration. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by 30 Jan 2022. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Anand Gaurav Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Thank you for stating the following in the Competing Interests section: [The authors have declared that no competing interests exist.]
We note that one or more of the authors are employed by a commercial company: Shanghai ChemPartner Co., Ltd., 576 Libing Road, Shanghai. a) Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form. Please also include the following statement within your amended Funding Statement. “The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.” If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement. b) Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc. Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf 3. In your Data Availability statement, you have not specified where the minimal data set underlying the results described in your manuscript can be found. PLOS defines a study's minimal data set as the underlying data used to reach the conclusions drawn in the manuscript and any additional data required to replicate the reported study findings in their entirety. All PLOS journals require that the minimal data set be made fully available. For more information about our data policy, please see http://journals.plos.org/plosone/s/data-availability. Upon re-submitting your revised manuscript, please upload your study’s minimal underlying data set as either Supporting Information files or to a stable, public repository and include the relevant URLs, DOIs, or accession numbers within your revised cover letter. For a list of acceptable repositories, please see http://journals.plos.org/plosone/s/data-availability#loc-recommended-repositories. Any potentially identifying patient information must be fully anonymized. Important: If there are ethical or legal restrictions to sharing your data publicly, please explain these restrictions in detail. Please see our guidelines for more information on what we consider unacceptable restrictions to publicly sharing data: http://journals.plos.org/plosone/s/data-availability#loc-unacceptable-data-access-restrictions. Note that it is not acceptable for the authors to be the sole named individuals responsible for ensuring data access. We will update your Data Availability statement to reflect the information you provide in your cover letter. 4. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The article entitled "Molecular dynamics simulations reveal the selectivity mechanism of structurally similar agonists to TLR7 and TLR8". Through molecular dynamics simulations, the authors aim to understand the mechanism of selective profiles of small molecule modulators against TLR7 and TLR8. The article falls within the scope of PLOS ONE, and may be considered for publication subject to rectification of the following issues: 1. Introduction is lengthy, kindly reduce the MD simulations part in the introduction section. 2. Page 14, line 295: However, the movement of the side chain weakens the van der Waals interactions between G and Phe351, Val381 and Ile585. line 298: It forms stronger electrostatic interactions with Asp555 and stronger van der Waals interaction with Val381 and Phe351. These two statements are contradictory. In the first statement, you mentioned the movement of the side chain weakens the van der Waals interactions between G and Phe351 and Val381. This means van der Waals interactions are weak in this complex. In the second statement, you mentioned molecule-H of G forms stronger van der Waals interaction with Val381 and Phe351. The van der Waals interactions in TLR7-G complex are weak or strong interactions? Kindly re-write this part. 3. In Fig6C, the residues Val381 and Ile585 do not appear in the figure, kindly include these two residues in the figure if they are important for the interactions as mentioned in page 14, line 296 and 299. 4. In Fig6F, the residues Thr574 and Val573 do not appear in the figure, kindly include these two residues in the figure as you mentioned there are H-bond interaction with Thr574 and Van der Waals interaction with Val573, page 14, line 304 and 305. 5. Page 14, line 302, you have mentioned interactions with Val378 of TLR8 but in Fig6D-E Val378 do not appear in any figure. Kindly include the residue in the figures. 6. There are many errors in English that should be improved. kindly use the same tense in your manuscript. 7. Errors need to be corrected as follow: 1. page 4, line 91: Up to now, MD simulations have been successfully applied to many large systems....million atoms. Change to “Up to date, MD simulations have been successfully applied to many large systems....million atoms.” 2. Page 5, line 110: In general, they are more potent on TLR7 than those on TLR8 (Table 1). Change to "In general, they are more potent on TLR7 than TLR8 (Table 1). 3. Page 7, line 160: The binding free energy (ΔGbinding) between a receptor and a ligand and can be estimated using Equation 1: Change to "The binding free energy (ΔGbinding) between a receptor and a ligand can be estimated using Equation 1:" 4. Page 7, line 166: ΔGbinding: the relative binding free energy. Kindly move this sentence to the beginning of the paragraph (line 163) before ΔEMM : the gas phase... 5. Page 8, line 187: It can be observed that the RMSD value in the TLR8 (apo).....that the TLR8 is more flexible in the presence of agonist. Is it presence or absence, kindly check as higher RMSD is associated with protein flexibility. 6. Page 10, line 239: On the other hand of the trajectory analysis, we also examine the conformational change of agonists. Change to "On the other hand of the trajectory analysis, we also examine the conformational changes of the agonists." 7. Page 11, line 241: The RMSD of agonists in TLR7 and TLR8 complex systems increase from the initial value (0 ns) to a scope of 1.0-3.0 Å and all reach maintain in this scope after 30 ns. Change to "The RMSD of the agonists in TLR7 and TLR8 complex systems increase from the initial value (0 ns) to a scope of 1.0-3.0 Å and maintain in this scope after 30 ns. 8. Page 11, line 246: The conformations of the three agonists were superimposed on the imidazoquinoline ring, and the initial frame (0 ns) and a frame near the late stage of the simulation (40 ns) were selected for comparison. Change to "The conformations of the three agonists were superimposed on the imidazoquinoline ring, the initial frame (0 ns) and a frame....comparison." 9. Page 11, line 248: The alignment at t= 40 ns of snapshot was chose to represent every conformation in the simulation 30-50 ns, the side chain orientations of the ligands in TLR7 (Fig 5C) and this in TLR8 (Fig 5F) are apparently different. Change to "The alignment at t= 40 ns of snapshot was chosen to represent every conformation in the simulation 30-50 ns, the side chain orientations of the ligands in TLR7 (Fig 5C) and TLR8 (Fig 5F) are apparently different. 10. Page 15, line 324: Agonists and representative residues are shown in orange and cyan stick. Change to "Agonists and representative residues are shown in cyan and orange stick." 11. Page 15, line 333: In TLR7-H, TLR7-R and TLR7-G systems, the stable hydrogen bonds formed in Asp555 and N and N1 atoms on agonists were maintained during the last 20 ns of the conformations. Change to "In TLR7-H, TLR7-R and TLR7-G systems, the stable hydrogen bonds formed between Asp555 and N and N1 atoms of the agonists were maintained during the last 20 ns of the conformations." 12. Page 15, line 334: In TLR7-H and TLR7-R systems, the occupancy of hydrogen bonds between Thr586 and N1 atoms on agonists (TLR7-H: 34.88%, TLR7-R: 43.83%) are similar. Change to "In TLR7-H and TLR7-R systems, the occupancy of hydrogen bonds between Thr586 and N1 atoms of the agonists (TLR7-H: 34.88%, TLR7-R: 43.83%) were similar." 13. Page 15, line 336: Nevertheless, the occupancy of the hydrogen bond between N1 and Thr586 of TLR7-G is very low (TLR7-G: 12.99%). Change to "Nevertheless, the occupancy of the hydrogen bond between N1 and Thr586 of TLR7-G was very low (TLR7-G: 12.99%)." 14. Page 15, line 338: Since N4 on G was protonated, a hydrogen bond formed between Thr586 of TLR7-G and N4, resulting in a change the orientation of the side chain and the loss of the hydrogen bond between Thr586 of TLR7-G and N2. Change to "Since N4 on G was protonated, a hydrogen bond formed between Thr586 of TLR7-G and N4, resulting in a change in the orientation of the side chain and loss of the hydrogen bond between Thr586 of TLR7-G and N2." 15. Page 15, line 342: The details of the hydrogen bonds... formed in Asp543 and N and N1 atoms on agonists were maintained during the last 20 ns of the conformations. Change to "The details of the hydrogen bonds... formed between Asp543 and N and N1 atoms of the agonists were maintained during the last 20 ns of the conformations. 16. Page 16, line 344: The occupancy of hydrogen bond between N1 and Thr574 of TLR8-G is zero. Do you mean no hydrogen bond formed between Thr574 and N1 of G in TLR8-G complex? 17. Page 16, line 359: are located around the aliphatic tail. And as shown in Fig 8B, the....TLR8-G. Change to "are located around the aliphatic tail. As shown in Fig 8B, the....TLR8-G." 18. Page 16, line 367: complex system is zero. And the occupancy...respectively. Change to "complex system is zero. Further, the occupancy...respectively. 19. Page 17, line 388: MD simulations and MM-GBSA method were used to model the overall conformational changes and calculate the binding free energies between three agonists and the TLR7 and TLR8. Change to "MD simulations and MM-GBSA method were used to model the overall conformational changes and calculate the binding free energies between three agonists and the receptors TLR7 and TLR8." 20. Page 17, line 389: Trajectory analysis showed that TLR7-R and TLR7-G systems form more “open” conformations during the simulation, however, other systems kept in closed conformations. Change to "Trajectory analysis showed that TLR7-R and TLR7-G systems formed open conformations during the simulation, however, other systems kept in closed conformations. 21. Page 17, line 392-393: Plus, the calculated binding free energies indicated that three agonists are more sensitive for TLR7 than TLR8, and the rank of the binding free energy values are in agreement with the experimental EC50 values in the cellular assay. Change to "Moreover, the calculated binding free energies indicated that the three agonists are more sensitive for TLR7 than TLR8, and the rank of the binding free energy values are in agreement with the experimental EC50 values in the cellular assay. 22. Page 18, line 397: The side chain nitrogen of G is positively charged in an acidic environment, leading to its much less favorite interaction with Ile585 of TLR7 and Val573 of TLR8. Change to "The side chain nitrogen of G is positively charged in an acidic environment, leading to less favorite interaction with Ile585 of TLR7 and Val573 of TLR8. Reviewer #2: The present work describes routine but useful simulations to understand the selectivity of agonists towards TLR7 and TLR8. The study was guided by binding free energy analysis, hydrogen bond analyses, decomposition of free energy. All the data have been presented either in main or supplementary text. The results obtained were almost aligned with the experimental results and helpful in determining the selectivity mechanisms. However the manuscript still require few explanations and language corrections. Suggestions for clarification or modifications: Line 13: replace “Highly” with “high” Line 25: Replace “experiment” with “experimental” Line 28: Replace “favor” with “favorable” Line 29: Replace “agonist in” with “agonist of” Line 29: Replace “imidazoquinolines” with “imidazoquinoline derivatives” Line 31: Replace “selective” with “selectivity” Line 32: Insights for “designing” more potent Line 36: Molecular dynamics simulations Line 50: both are located Line 57: diseases and can be used as good adjutants of vaccines Line 62: “many distributional and functional” Line 71: “selectivity mechanism of small molecule agonists of TLR7 and TLR8d TLR8” Line 80: pH Line 89: replace “structural” to “structure” Line 100: replace “against” with “for” Line 111: replace “first” with initially Line 112: remove “respectively”. Replace second with “thereafter” Line 116: replace “selectivity mechanism” with “selectivity” Line 128-29: The TLR7-H system was modeled based on coordinates of TLR7-R by replacing the oxygen to carbon atom. (Mention the aliphatic chain) Section 2.2 change heading to “Molecular dynamics simulations” Line 148: replace Cl-1 to Cl- Line 149: “steepest descent algorithm” Line 154: 50ns is not a long-time simulation. Just mention 50 ns simulation. Section 2.3 equations must be included for “∆EMM : the gas phase energy consisting of electrostatic (∆Eelec) and van der Waals (∆EvdW) terms. ∆Gsolv : solvation energy including both the polar solvation energy, ∆Gpolar and the nonpolar solvation component, ∆Gsurf” Line 192: “confirmational” Line 197: capitalize “In” Line 201: remove “are both”. Line 202: “The distance changes in TLR7-H, TLR8-R, TLR8-H and TLR8-G systems are not evident (Fig 3C and Fig 3D). In apo systems, the distance changes in TLR7 and TLR8 systems are also not evident (Fig 3C and Fig 3D).” This point should be made clearer by showing the distance (angstrom) in Fig 3A and 3B. or by superimposing TLR7 and TLR8 with highlighted anchor residue distances. Line 217: replace scope with “range” Line 235: replace “On the other hand of the” by “In another” & change to “changes” Line 245: replace chose to “chosen” Line 246: remove “this is” Line 256: TLR7 and TLR8 Line 260: while G shows the lowest Line 270: energy is unfavorable to binding include the values here. Table 1. Comparison of predicted binding free energies and experimental EC50 values of R, H and G with TLR7 and TLR8 SEM (standard error of means) should be reported for all the BFE values e.g -44.21 ± ?? in all the tables. Table 2. replace “Item” to “Energetic contributions” All energetic contributions should have uniform representation e.g. ∆Evdw, ∆Eele…… All units are in kcal/mol. Line 293: “It forms stronger electrostatic interactions with Asp555 and stronger van der Waals interaction with Val381 and Phe351” should be supported with energy values Line 306-09: these are repeated lines. Remove. Line 310: “The residue of TLR8 alignment to Leu557 of TLR7 is Asp545, which might result in a weaker interaction with agonists.” rewrite to make it more understandable. Line 327: Similar codes (either 3 letter or single) for amino acids should be used in text and figures. Line 332: side chain and hence the Caption Fig 7. “the important atoms” Line 364: two or one TLR7 please specify Line 382: remove “the” before TLR7 and TLR8. Line 384: “pockets” to pocket Line 392: less favorable interactions Line 396: each agonist Line 394: quiet to “quite” Need to address these questions?
6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
PONE-D-21-35895R1Molecular dynamics simulations reveal the selectivity mechanism of structurally similar agonists to TLR7 and TLR8PLOS ONE Dear Dr. Jinxia Nancy Deng, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Apr 25 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Anand Gaurav Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: N/A Reviewer #2: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors have addressed all the comments, however, there are additional comments that need to be addressed by authors before the acceptance of the manuscript. - Page 4, line 77. Kindly remove this part from the paragraph, "In the late 70s, the first case of MD is Bovine pancreatic trypsin inhibitor [26]. Especially in recent years, benefit from the development of modern hardware and force fields, MD simulation has made huge progress. Protein conformation dynamics that is hardly available by current experimental techniques can be observed using MD simulations [27-34]." as it is extra and does not add scientific value to your manuscript. So the updated paragraph will be "Molecular dynamics (MD) simulation is a very established computational technique to understand the protein structure-function relationship and guide the drug design. MD simulation has played an important role in characterizing receptor-ligand interaction....with a simulation time of 10-100us [55-57]. -Page 11, line 246. "In another trajectory analysis, we also examine the conformational changes of agonists. The heavy atom RMSD of agonists was calculated in the six TLR-agonist systems (Figs 5B and 5E) with respect to the initial conformation." Kindly change it to " We also examine the conformational changes of agonists. The heavy atoms' RMSD of agonists was calculated in the six TLR-agonist systems (Figs 5B and 5E) with respect to the initial conformation." -Page 16, line 349. "The occupancy of hydrogen bond between N1 and T574 of TLR8-G is zero." Kindly remove this sentence since there is no hydrogen bond between N1 and T574 of TLR8-G. Reviewer #2: (No Response) ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 2 |
|
Molecular dynamics simulations reveal the selectivity mechanism of structurally similar agonists to TLR7 and TLR8 PONE-D-21-35895R2 Dear Dr. Jinxia Nancy Deng, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Anand Gaurav Academic Editor PLOS ONE Additional Editor Comments (optional): Dear Author, The revised manuscript addresses all the comments of the reviewers and the manuscript can be accepted in the current form. Regards Anand Guarav, PhD Reviewers' comments: |
| Formally Accepted |
|
PONE-D-21-35895R2 Molecular dynamics simulations reveal the selectivity mechanism of structurally similar agonists to TLR7 and TLR8 Dear Dr. Deng: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Anand Gaurav Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .