Peer Review History
| Original SubmissionJanuary 21, 2021 |
|---|
|
PONE-D-21-00512 Practical considerations for Ultraviolet-C radiation mediated decontamination of N95 respirator against SARS-CoV-2 virus PLOS ONE Dear Dr. Stanley, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. I am returning your manuscript with comments from two reviewers, who you will see, came to similar conclusions. Both found the paper very interesting but had a number of queries about the methods used. I agree that the methods section is currently very brief and important information is either missing or included as supplementary material rather than main text. For example, the treatment of control (non-exposed) masks/surfaces should be clarified - was virus recovered after the 3.5 h drying time (0 sec exposure) or were masks placed in the chamber and exposed to 0 mJ/cm2 for 300 and 600 seconds? Similarly, straps were not subjected to the 3.5 h drying time and, whilst it is stated (supplementary data) that no losses in viability occurred over the 3.5h drying time, could desiccation stress increase virus susceptibility to subsequent UV-c exposure? Whilst some of the additional information asked for by the reviewers can be considered supplementary, please ensure sufficient detail is provided within the main text. If possible, and as suggested by both reviewers, please also include a picture of the chamber and configuration of the masks within. I would also draw specific attention to comments made by Reviewer 2 and their concerns relating to data interpretation. Please ensure your conclusions are supported by the data and that limitations of the study have been acknowledged. Finally, and as highlighted by Reviewer 1, it could be perceived that some of the listed authors have competing interests. Please address and/or declare as appropriate. Please submit your revised manuscript by May 23 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Ginny Moore Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Thank you for stating the following in the Financial Disclosure section: [This work was funded by Fast Grants (part of Emergent Ventures at George Mason University) to SAS. AWR is supported by a LSRF fellowship.]. We note that one or more of the authors are employed by a commercial company: Verily Life Sciences, Arkesso LLC and Bolb Inc.
Please also include the following statement within your amended Funding Statement. “The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.” If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement. 2. Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc. Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf. Please know it is PLOS ONE policy for corresponding authors to declare, on behalf of all authors, all potential competing interests for the purposes of transparency. PLOS defines a competing interest as anything that interferes with, or could reasonably be perceived as interfering with, the full and objective presentation, peer review, editorial decision-making, or publication of research or non-research articles submitted to one of the journals. Competing interests can be financial or non-financial, professional, or personal. Competing interests can arise in relationship to an organization or another person. Please follow this link to our website for more details on competing interests: http://journals.plos.org/plosone/s/competing-interests [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Partly ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: I Don't Know Reviewer #2: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Review of PONE-D-21-00512 Interesting short report showing differences in mask decontamination. Could do with more results because it was only completed twice for each mask and the results lack some potential significance in interpretation due to it. It would also be interesting to have completed the study on masks that had already been worn because this is how they would be presented when decontaminated in reality. There is no evaluation of the effects angular incidence causes on the decontamination results as mentioned in the introduction. Conflicts of interest, there are authors from the companies that have produced the LEDs for the UV chamber you have used. I would say that this needs to be declared since you say that UVc is a technology that can be used to disinfect masks and will be improving in the future which could benefit the companies producing the LEDs. Why did you choose the sites for the contamination of the masks? Why did you only test two models of the mask? Was it because these were the only ones being used in the University or were they chosen because their properties were thought to give different results from the exposure? The last sentence in the introduction is not needed. How did you stop the droplet inoculum from spreading on the non-horizontal surfaces if they were all inoculated at the same time? How does this vary from just adding 50ul in one go? Were the 3 inoculums added to exactly the same spot? Did you add each inoculum and leave it to dry prior to adding the next? If not added together how does this represent contamination when masks are used in practice? More information on the UVc exposure chamber is needed and positioning of the masks inside it, or was each mask exposed separately? Maybe a picture of the chamber would help in the description, the brief section in the results/discussion section should be moved into the materials and methods. Was there a temperature increase in the exposure device during operation? More information on the methods is needed or should be included in the supplementary file. How was the CPE visualised, was a stain used? Please explain what were the aluminium coupons used for (virus titration section)? Why were aluminium coupons chosen over stainless steel for coupons? Were the coupons excised from the mask agitated in the recovery medium? What was the loss of viability over the course of the experiment from exposure to the environmental conditions inside the UVc chamber without the LEDs being switched on? Could an increase in heat have contributed to the reduction in viability of the virus? Please include a reference for the statement identifying that a 3-log reduction is the industry standard for an effective decontamination. The results from the aluminium show a close to 5 log reduction, not an actual 5 log reduction. The text needs to be changed to reflect this. How were the aluminium coupons presented in the chamber and how does this relate to the inoculated masks (distance, orientation)? What was the maximum log reduction that could be achieved in this assay? Some more interpretation of the surface types would be good for the discussion. You mention the 1860 was hydrophobic, but being made from polyester, was the 8210 hydrophobic as well? How did the inoculum present on the surfaces i.e. did they stay as droplets on the material or were they absorbed, and how do you think this would have affected the exposure? Do you think the colour differences of the masks played a role in the decontamination? How close were your exposure doses to those that would compromise material integrity? Supplementary file You mention that “Details on virus propagation can be found in supplementary materials” but that is in the supplementary file. Please clarify. What type of Biosafety cabinet was used for the drying of the masks? Reviewer #2: The paper entitled “Practical considerations for Ultraviolet-C radiation mediated decontamination of N95 respirator against SARS-CoV-2 virus” is well written however would benefit from a more comprehensive review of the literature in the introduction and discussion . The contents add to the body of literature on decontamination of respirators and discuss important information on practical considerations for these processes. Of great importance is their discussion on variability in efficacy of UV-C depending on respirator model and mode of testing (swatches vs. whole masks). The article could be improved upon by including a more in depth look at current respirator UV-C disinfection practices and the advantages / disadvantages of these methods. I have a few minor comments and questions. Questions and comments: Page 2. In the introduction, address if any facilities are using UV-C decontamination for respirators currently or during the peak of the pandemic? This would put the article into context with current practices and would be helpful either in the introduction or discussion. Examples are Ozog et al. 2020 and Golladay et al. 2021. Page 2: In the introduction or discussion include the benefits / disadvantages to respirator disinfection with UV-C vs. other methods. This will give the reader a more comprehensive view on what is practical for their facility. Page 3. Instead of referring to the ambiguous industry standard it would be better to cite the FDA’s “recommendations for sponsors requesting EUA’s for decontamination and bioburden reduction systems for surgical masks and respirators during the (COVID-19) public health emergency” document. Include in the discussion or introduction that there is currently only 1 UV-C device with an EUA for respirator disinfection. Page 4. Mask inoculation and UV-C exposure – indicate that only the exterior of the mask was tested. This limits use of the respirator to the to the same user. Do you have a comment on importance (or lack there of?) of disinfecting the internal fibers and interior of the respirator? Page 4. The description of the UV-C disinfection device should be under materials and methods, not results and discussion heading. If possible, it would be helpful to include an image of the device and placement of the mask in the supplementary files. S1 File: Extended Material and Methods page 2 – indicate source and model for calibrated UV-C sensors. Page 5. Figure: UV-C decontamination of multiple locations on two models of N95 respirators: Panel B) Indicate in the legend that it is showing each site independently with the dots then an average of all sites with the bar graph. Page 5. Reference FDA recommendations instead of “industry standard”. Page 7 line 3 – Were irradiation doses carried out on the 8210 model as well? If the irradiation doses on the 8210 and 1860 are the same in the various locations, then the material of the mask is the major influencing factor. It is possible that there is a small change in the shape of the 8210 compared to the 1860 that hinders the efficacy of UV-C. Page 7 line 14 and 15 – if you conducted this same testing on swatches of mask would you see this same result? This would solidify that it is the material that is the major factor in efficacy. Did treated masks pass fit and filtration testing? If not tested, it needs to be indicated as a limitation of the study. Testing of only the exterior of the mask needs to be included as a limitation of the study. Discussion: It would make sense that the center of the mask would have the highest irradiation levels since it is closes and most parallel to the LEDs however it does not. The best reduction is occurring at the edges of the mask, any thoughts on why that is? ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
Practical considerations for Ultraviolet-C radiation mediated decontamination of N95 respirator against SARS-CoV-2 virus PONE-D-21-00512R1 Dear Dr. Stanley, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Ginny Moore Academic Editor PLOS ONE Additional Editor Comments (optional): Please check the last line on page 2 of the revised document "4 of the 3 most promising methods" Please check title of Table and confirm that "average" is the mean (or not) Page 10 of the revised document - you mention "large variability". Whilst this is illustrated to some extent in the figure, you could consider adding this data to the table (e.g. providing a standard deviation or range of reductions) Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: I Don't Know ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: (No Response) ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No |
| Formally Accepted |
|
PONE-D-21-00512R1 Practical considerations for Ultraviolet-C radiation mediated decontamination of N95 respirator against SARS-CoV-2 virus Dear Dr. Stanley: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Ginny Moore Academic Editor PLOS ONE |