Peer Review History
| Original SubmissionMay 7, 2021 |
|---|
|
PONE-D-21-14944 Evaluation of a Bioaerosol Sampler for Indoor Environmental Surveillance of Severe Acute Respiratory Syndrome Coronavirus 2 PLOS ONE Dear Dr. Van den Wymelenberg Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. In full agreement with the reviewer there are several important issues; Firstly ; authors should provide a detailed description of the aerosols generated by the system and according to particle size monitoring explain why such aerosols resemble that generated by a human upon breathing. Secondly. An accurate description of the particles present in the aerosols experimentally generated; how close are the particle ranges in the in vitro generated aerosols and in that generated by a human. Thirdly. Once infected by Cov2 people might be hospitalized and kept in rooms that benefit from constant air filtration. Under these conditions are aerosols exhaled by a human detected and for how long? Please submit your revised manuscript by Sep 13 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Jean-Luc EPH Darlix, MG, Ph.D. Academic Editor PLOS ONE Journal requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Thank you for stating the following in the Competing Interests/Financial Disclosure* (delete as necessary) section: “I have read the journal's policy and the authors of this manuscript have the following competing interests: Van Den Wymelenberg has a company called Duktile through which he provides healthy building consulting, including consulting related to viral pathogens, and he serves as a scientific advisor to EnviralTech, a company that conducts viral environmental surveillance, including in senior care facilities.” We note that one or more of the authors are employed by a commercial company: name of commercial company. a. Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form. Please also include the following statement within your amended Funding Statement. “The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.” If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement. b. Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc. Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf. 3. We note that you have included the phrase “data not shown” in your manuscript. Unfortunately, this does not meet our data sharing requirements. PLOS does not permit references to inaccessible data. We require that authors provide all relevant data within the paper, Supporting Information files, or in an acceptable, public repository. Please add a citation to support this phrase or upload the data that corresponds with these findings to a stable repository (such as Figshare or Dryad) and provide and URLs, DOIs, or accession numbers that may be used to access these data. Or, if the data are not a core part of the research being presented in your study, we ask that you remove the phrase that refers to these data. Additional Editor Comments (if provided): [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Partly ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors describe the testing of a commercially available impaction-based bioaerosol sampling system to detect SARS-CoV-2. They first evaluated specific collection media and their use in typical lab procedures required to extract virus. They identified two media that withstood processing and provided consistent measurements in terms of cycle threshold (Ct). They then performed bench and room scale aerosol collection experiments using a Thermo Scientific AerosolSense Sampler. Investigators cultured and heat deactivated SARS-CoV-2 and nebulized it at concentrations from 0.0032 – 320 genome copies/L air in the glove box. In a room scale experiment, they aerosolized solutions to generate aerosols with 3.2-32000 genome copies/L air. The also investigated the effects of humidity, delayed sample processing, and high dust loads on collection efficiency. My first issue with the manuscript is that there is very little detail presented on the aerosol generation systems used and no justification that these provide an accurate depiction of the aerosols generated by a human. There’s some amount of literature on the characteristics of exhaled aerosols and as the authors describe in the introduction. Their sizes range from submicron through 100’s of microns. My concern is that the authors may have used something akin to a medical nebulizer which produces aerosol only within a narrow range (apx. 1-10 microns). Information on the aerosol sizes generated for both the room and glove box experiments needs to be added to the methods and compared to the aerosol sizes generated by exhaled aerosols from people. Associated limitations for the study should be added to the discussion. My second issue is that the manuscript doesn’t report the aerosol size range detectable by the sampler. From the product manual this range seems to be 0.1-15 microns in diameter. (https://assets.fishersci.com/TFS-Assets/CAD/Flyers/aerosolsense-faq.pdf ). The problem there is that’s only a small fraction of the aerosol sizes that might be generated by a person and that this device may provide a false sense of security because it may miss aerosols generated in larger aerosol size ranges which could contain substantially more virus that aerosols of the order of 1-10 microns. These aerosols would have shorter settling times, but still could circulate within a room. Information on the detectable aerosol size ranges for the collector should be reported in the methods. This should be compared to the aerosol sizes generated by exhaled aerosols from people. Associated limitations for the study should be added to the discussion. Minor: Methods: “SARS-CoV-2 deposited by CDC…” Is deposited the correct word? Methods: Define Ct at first use Methods: Describe the aerosol sizes generated by the bench and room nebulizer systems. Results: In the studies media authors should define which end of their Likert scale is best and which is worst. This information should also be included in the caption of Table 3 ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Tim Corcoran [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
Evaluation of a Bioaerosol Sampler for Indoor Environmental Surveillance of Severe Acute Respiratory Syndrome Coronavirus 2 PONE-D-21-14944R1 Dear Dr. Van Den Wymelenberg We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Jean-Luc EPH Darlix, MG, Ph.D. Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: |
| Formally Accepted |
|
PONE-D-21-14944R1 Evaluation of a Bioaerosol Sampler for Indoor Environmental Surveillance of Severe Acute Respiratory Syndrome Coronavirus 2 Dear Dr. Van Den Wymelenberg: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Professor Jean-Luc EPH Darlix Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.