Peer Review History

Original SubmissionFebruary 5, 2021

Attachments
Attachment
Submitted filename: Questions to authors - Kinahan.docx
Decision Letter - Vladimir Mikheev, Editor

PONE-D-21-03983

Aerosol tracer testing in Boeing 767 and 777 aircraft to simulate exposure potential of infectious aerosol such as SARS-CoV-2

PLOS ONE

Dear Dr. Kinahan,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Thank you for submission of this very important manuscript.

Four experienced aerosol scientists (2 from US and another 2 from outside US) have agreed to review your manuscript.

All reviewers feel very positive about your manuscript although some minor revisions are recommended.

Those recommendations include: discussion on virus inactivation rate, quality of some of the figures, discussion on actual particle size that could contain virus in real-world (theoretically droplet containing single virus may dry down to ~100 nm but till it reached ~50 nm Brownian diffusion still should be very moderate therefore I would consider 1 micron size that you used for testing as appropriate but it should be discussed), mask fitting (mannequin vs real humans face) and more details on masks used (type, manufacturer), status of personal air-vents (In supplemental materials gaspers ON or OFF Columns are presented in the Tables, but there is not enough info about gaspers status in the main text. So, I would agree with this question and would like to have it more clearly written in the main text), location of IBAC sampling inlets (envisioning this question I've tried to clarify it with you prior to send manuscript to reviewers, but it seems like some more clarification is still needed).

Important question has been asked if your results are applicable to other environments (such as restaurants) and although this is of course out of scope of your work but recommendations on conducting similar studies in other populated environments could be discussed.

There are other minor comments/questions that you can find while reading each reviewer feedback.

So, I would like to request these minor revisions and hope after these revisions been made we can proceed with publication.

Please submit your revised manuscript by April 23, 2021. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Vladimir Mikheev

Academic Editor

PLOS ONE

Journal Requirements:

Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. Thank you for stating the following in the Financial Disclosure section:

"This work was funded through Zeteo Tech, Inc. by United States Transportation Command (USTRANSCOM - https://www.ustranscom.mil/).

Defense Advanced Research Projects Agency (DARPA - https://www.darpa.mil/). reviewed test plans and USTRANSCOM reports for editing and technical direction"

We note that you received funding from a commercial source: Zeteo Tech, Inc.

Please provide an amended Competing Interests Statement that explicitly states this commercial funder, along with any other relevant declarations relating to employment, consultancy, patents, products in development, marketed products, etc.

Within this Competing Interests Statement, please confirm that this does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests).  If there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared.

Please include your amended Competing Interests Statement within your cover letter. We will change the online submission form on your behalf.

Please know it is PLOS ONE policy for corresponding authors to declare, on behalf of all authors, all potential competing interests for the purposes of transparency. PLOS defines a competing interest as anything that interferes with, or could reasonably be perceived as interfering with, the full and objective presentation, peer review, editorial decision-making, or publication of research or non-research articles submitted to one of the journals. Competing interests can be financial or non-financial, professional, or personal. Competing interests can arise in relationship to an organization or another person. Please follow this link to our website for more details on competing interests: http://journals.plos.org/plosone/s/competing-interests

3. Thank you for stating the following in the Competing Interests section:

"The authors have declared that no competing interests exist."

We note that one or more of the authors are employed by a commercial company: S3I LLC.

3.1. Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form.

Please also include the following statement within your amended Funding Statement.

“The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.”

If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement.

3.2. Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc.  

Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to  PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and  there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared.

Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf.

Please know it is PLOS ONE policy for corresponding authors to declare, on behalf of all authors, all potential competing interests for the purposes of transparency. PLOS defines a competing interest as anything that interferes with, or could reasonably be perceived as interfering with, the full and objective presentation, peer review, editorial decision-making, or publication of research or non-research articles submitted to one of the journals. Competing interests can be financial or non-financial, professional, or personal. Competing interests can arise in relationship to an organization or another person. Please follow this link to our website for more details on competing interests: http://journals.plos.org/plosone/s/competing-interests

4. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information.

5. Thank you for submitting the above manuscript to PLOS ONE. During our internal evaluation of the manuscript, we found significant text overlap between your submission and the following previously published works.

- https://images.radio.com/connectingvets/TRANSCOM%20Report%20Final.pdf

We would like to make you aware that copying extracts from previous publications, especially outside the methods section, word-for-word is unacceptable, even for works which you authored. In addition, the reproduction of text from published reports has implications for the copyright that may apply to the publications.

Please revise the manuscript to rephrase the duplicated text, cite your sources, and provide details as to how the current manuscript advances on previous work. Please note that further consideration is dependent on the submission of a manuscript that addresses these concerns about the overlap in text with published work.

We will carefully review your manuscript upon resubmission, so please ensure that your revision is thorough.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: Yes

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: I Don't Know

Reviewer #3: Yes

Reviewer #4: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: Dear authors,

Major remark.

You used different tracers to study aerosol propagation in real aircrafts environments. But viruses in aerosols lose their biological activity at a rate that is a function of temperature, relative humidity, and other parameters. Therefore, the measurements carried out by the authors give only an upper estimate of the biological activity of the virus containing aerosol at the measurement points. This remark does not affect the conclusions drawn in the article about the low probability of passengers’ infection even in the nearest seats, however, I believe that the text of the article should contain a paragraph or two on the inactivation of SARS CoV-2 in aerosols, especially since information on the dependence of the inactivation rate of this virus on the above parameters are already presented in the literature.

Minor remarks:

L48: there should be reference (2) instead of (1);

L563: please remove the journal's name after paper authors

Figs 2 and 3 are presented in the paper in very bad quality.

Reviewer #2: This is a well-designed, elaborate study to measure the exposures associated with aerosol transmission from a single source within a Boeing 767 and 777 aircraft. While the results may be somewhat predictable from modeling airflow in these environments these are dramatic experimental data showing generally less than 0.1% at seats that are very close in proximity to the source of aerosol transmission. My specific comments are directed mostly at clarity and some further discussion of limitations in terms of particle size and use of face masks.

1. Abstract. “We completed over 65 releases of 180,000,000 fluorescent particles …” This seems unnecessary and likely not that precise, e.g. 65 releases of 180M each or all together? At least change to exponential notation.

2. Page 7. “2.2. 777-200 Testing. During the two days of in-flight testing, fluorescent tracer particles were released in the AFT, MID AFT, FWD, and FWD-MID sections of the airframe for a total of 64 releases. The breathing releases included 40 tests with the mannequin not wearing a mask and 24 tests with a mask.” This seems critical to understanding your methods/design and thus may need some clarification at this point. Fluorescent tracer particles nebulized? With what nebulizer? Were they fluorescent beads or solution? You give more specifics on these later in methods but some of the basic information would be helpful here.

3. Page 8. “The test sizes were chosen…” The sizes you chose to test are supported by your references and appropriate for your sampling methodology, APS, for particles larger than 0.5um but some data also show that the size of the Covid-19 virus ranges from 75 to 200 nm (e.g. Chen N et al. Lancet 2020;395:507), outside the range of the APS (i.e. may need SMPS and/or CPC to count these smaller particles). It’s clear that you can’t test the full range of particle sizes that may contain virus but you should include the potential for smaller sizes in your discussion of limitations associated with your choices. The smallest airborne viruses would likely have different mobility than 1um particles, i.e. the former more diffusive.

4. Page 11. “Standard surgical 3-ply masks …” What was type/manufacturer of mask? These may vary in terms of filtration efficiencies across manufacturers and fit to the face (especially a mannequin).

5. Page 16 and Table 2. 767 has better filtration than 777 despite having lower ACH? Other differences to explain this?

6. Page 18 and table 3. “As further evidence of the mannequin’s mask redirecting particles rather than filtering them …”. Again this may be due to poor mask fitting for the specific mask used and the fact that it was on a mannequin as opposed to an actual face. Should state as limitation of this aspect of the study.

Reviewer #3: This is a well-conducted and complicated study analyzing the horizontal spatial dispersion of particles meant to simulate those produced during normal breathing on two common intermediate-to long-trip commercial aircraft. The results show relatively low dispersion in both amount and distance, and validates the ventilation plans in these aircraft. Although this study is in response to the pandemic of the Covid 19 virus, it is generic enough to be relevant to nearly all respiratorilly generated communicative diseases. However, it does not take into account coughing and sneezing, which may or may not be the predominant form of transmission.

Review comments

1. Page 2, line 30, Abstract. The 65 releases are hard to associate with the reported 85 releases for the 767 and 64 releases of the 777 listed on page 7, Methods.

2. Page 5, line 107. This sentence announces over 300 releases.

3. Page 6, line 125. Were personal air vents on or off? My experience indicates most passengers usually have them on for varying flows. This can likely disturb flow from seat to seat or reduce particle count within the cone of air flow.

4. Page 7, line 59. 767-300 testing. Occasional power loss. When? How many times? During testing? Were tests repeated? Are these included in the 85 releases?

5. Page 7, why are there 64 releases for 777 and 85 releases for 767? Specific test configurations/seating are difficult to determine: i.e., were there more than triplicate tests per seat or other tests? For instance, for the 767, there were 9 seats listed for triplicate, both mask and no mask tests. That adds up to 9 (seats)X3 (triplicate)X2 (masks)=54 tests. Yet 85 releases reported.

6. Page 9, line 207. I am unfamiliar with IBACS. Were the IBAC sensor inlets located near typical face level and position?

7. Figure S2. I think I can only count 2 IBACS in the image although 4 is mentioned.

8. Could the volume taken up by actual persons in the seats change the results significantly? For instance, if a person takes up 25% of the volume in the sampled area, the counts would be the same, but concentration necessarily increases proportionally. And it may be important that concentration, in addition to counts, is important to infection.

9. Page 20, line 448-454 Discussion should mention status of personal air vents.

Reviewer #4: Review

Ms. Ref. No.: PONE-D-21-03983

Title: Aerosol tracer testing in Boeing 767 and 777 aircraft to simulate exposure potential of infectious aerosol such as SARS-CoV-2

Plos one

General comments:

This manuscript presents a study of aerosol release inside two aircrafts simulating potential exposure to SARS-CoV-2 viruses. The study is very topical and important. I recommend publication after my comments have been taken into account. These general comments are mainly my questions and opinions after reading the manuscript and any additions in these directions could help making the study more impactful. However, I let the authors decide how they can best respond to these comments.

Overall, this study is interesting, it is well designed and conducted, and provides important results concerning potential exposure to any air pollutants within an aircraft. As a first comment, I would like to see a critical disclaimer concerning the validity of this study in predicting the exposure to SARS-CoV-2 viruses. It is known from the literature that the size of SARS-CoV-2 virus is of the order of 120 nm. However, in some situations these viruses may exist as larger particles/droplets containing many viruses together with other material from sneezing, coughing, etc. Since the experiments of this study have been conducted using 1 and 3 �m particles, they do not exactly simulate the virus particles. In addition, the particle behaviour in an airflow and entering the sampler inlet is size dependent and behaviour of the two extremes – 120 nm and 3 �m – is very different and determined by different processes such as gravitational settling or inertia. These discussions could be added in the Discussion section to avoid too straightforward conclusions from these results to real life exposure.

It may be out of the scope of this study, but I remained curious to know whether the main results are something untypical in exposure scenarios or are these results similar to other potential exposure situations. In other words, it is expected that any point release of particles will be diluted as it enters the space in question and the question is if the reductions measured in this study indicate that the transport of viruses and consequently the exposure is insignificant. This study shows a minimum reduction of 99.54% of 1 μm aerosols from the index source to the breathing zone of a typical passenger seated directly next to the source. Would this value be similar or different in e.g. a restaurant situation with two people sitting next to each other?

Detailed comments:

The units: This is probably somewhat European perspective, but I find it always somewhat confusing that a mixed set of units are used. Naturally, it is the Journal policy, that determines the preferred unit system. I list here some of my observations:

-Line 126: The volume is given as cubic feet.

-Line 172: The particle concentration is given as “particles per liter of air”. Here the authors use different volume unit than previously. The abbreviation (pla) is unknown for me. This is used e.g. in line 200.

-Line 203: The instrument sampling rate is given as liters per minute (lpm).

-Line 236: The volume is given as milli liter, mL. Now the unit is written with capital L.

All of these are easy to understand, but perhaps some systematic way of using different units and symbols could be used.

Mask: I concluded that the mask was used for the mannequin that was the source of the particles. However, when reading the manuscript it was not immediately clear whether the source or the target was wearing the mask. This confusion is probably due to the fact that the discussion concerning the mannequin and the mask started already line 150, before the particle release process had been introduced (it comes rather late at chapter 2.8.).

The release process and the role of mannequin, chapter 2.4: The role of mannequin remained unclear. If I understand correctly, the aerosol release took place through the mannequin mouth/nose. However, the details remained unclear.

The size distributions, line 175 and supplemental fig 3: It is unclear what is presented in this figure. The y-axes unit for a size distribution is the size distribution function, not the concentration. The size distribution function is the concentration in given size bin normalized by the width of the bin, i.e. #/(cm3*(Dpmax-Dpmin)) which gives the unit for y-axes #/(cm3*�m). If the authors use the commercial instrument software this unit is probably the correct one automatically provided.

What is “ta” in line 179?

The sentence in lines 185-187 if difficult to understand.

The mask tests, chapter 3.2: What is the particle size used in these tests? If both particle sizes were used, was there any difference in the resulting reduction?

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

Reviewer #3: Yes: Kirby L Zeman

Reviewer #4: Yes: Kaarle Hämeri

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Attachments
Attachment
Submitted filename: Review_PONE-D-21-03983.docx
Revision 1

Please see attached response letter for a point by point acknowledgment. Essentially all recommended changes were incorporated.

Attachments
Attachment
Submitted filename: Manuscript Response to Reviewers Letter.docx
Decision Letter - Vladimir Mikheev, Editor

PONE-D-21-03983R1

Aerosol tracer testing in Boeing 767 and 777 aircraft to simulate exposure potential of infectious aerosol such as SARS-CoV-2

PLOS ONE

Dear Dr. Kinahan,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please see my detailed comments below.

Please submit your revised manuscript by August 15, 2021. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Vladimir Mikheev

Academic Editor

PLOS ONE

Journal Requirements:

Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

Additional Editor Comments (if provided):

Dear Dr. Kinahan,

Thank you for revising the manuscript and addressing reviewer’s comments.

I think your manuscript is now in a much better shape but several minor edits/corrections are still required, please see below.

Line numbers were used from the “Revised Manuscript with Track Changes” version:

L52: “While large-droplet transmission likely does not vary substantially from the unique circumstance of being on an aircraft, the aerosol exposure route is dependent on the ventilation, environment”

Indicate please size of “large droplets”.

L160: tests with a mask. Methods sections 2.4, 2.5, and 2.8 describe aqueous tracer solutions and

You don’t have these 2.4, 2.5, and 2.8 numbering anymore.

L180: “minutes, and then placed into a static mode without airflow. The test solution, which is a 10% dilution of the stock solution in deionized water, was nebulized identically to in-flight tests, from a nebulizer plumbed to a mannequin (fluorescent tracer) with or without a mask, or without a mannequin (DNA-tagged tracer) and then briefly mixed using two remote-controllable fans (20-25 seconds).”

What was the stock solution?

Fluorescent tagged microspheres were aerosolized for one minute in a breathing pattern for 2 seconds on and 2 seconds off, correct?

L190: “for each release condition has low standard error around the mean, with a total number of fluorescent tracers when unmasked of 1.8*10^8, compared to 2.4*10^7 beads for the larger 3 µm DNA-tagged tracers (Table 1)”.

In the Table 1 you have both with and without mask results for fluorescent tracers but not in the text. I would suggest to add results for with masks (in the brackets): “for each release condition has low standard error around the mean, with a total number of fluorescent tracers when unmasked of 1.8*10^8 (with mask 1.7*10^8) compared to 2.4*10^7 beads for the larger 3 µm DNA-tagged tracers (Table 1)”.

L206: “sizes become increasingly sub-micron the effects of gravity vs Brownian motion”

For submicron particles its not a gravitational force – its inertial force. So I would change it to:

“sizes become increasingly sub-micron the effects of inertial forces vs Brownian motion”

L229: “IBAC sensors were placed in individual seats, with either 1 foot tubing extensions to actively sample within the breathing zone or placing on a collapsible crate to achieve the same sampling location”

How long was the sampling time?

L235: “for isokinetic sizing and alignment with a flow field”

Isokinetic sampling (not sizing)

L240: “typical resting passenger minute volume (7.5 lpm) rather than the instruments sampling rate of”

I think you need to clarify respiratory minute volume

L263: “(Sartorius), which operated for fifteen minutes, and collects 99.9995% of particles”

Need to specify instrument specs: what particle size range it collects

L265: “Five high volume air collectors were distributed near release”

Are those the same Airport MD8 or different air-samplers?

L289: “minutes and fluorescent tagged microspheres were generated aerosolized for one minute in a breathing pattern for 2 seconds on and 2 seconds off”

That is for both in the Chamber and on the plane tests, correct?

L316: “Economy (with and without a mask) and first class penetration percentages for nearby seats on the”

Although you previously explained very clear that terms “with and without a mask” relate to mannequin release of particles, some readers might still be confused and may think that here you are talking about mask protection for inhalation. I understand that for attentive reader it should be clear that you didn’t put mask on IBAC, but some people may still think that you somehow assessed mask inhalation protection. To avoid this potential confusion, I would suggest something like: “Economy (mannequin particles release with and without a mask)”. And for the Table 2 instead of “Breathing w/o mask or w/mask” I would also recommend to use “mannequin particles release with and without a mask”. Same comment for Fig 2 Caption: term “unmasked breathing” might be confusing.

Supplemental Tables 7 and 8 include “coughing” test conditions – What does it mean? I don’t think there is any mentioning about testing “coughing conditions” in the text.

Once again: What I didn’t find is how long was the IBAC sampling after each release. 15 min (same as Airport MD8 aerosol samplers)?

I also think that short discussion about how your data correspond to the real-world conditions is required. Please see below some thoughts:

According to Asadi 20201: “certain individuals are “speech superemitters” who emit an order of magnitude more aerosol particles than average, about 10 particles/second. A ten-minute conversation with an infected, asymptomatic superemitter talking in a normal volume thus would yield an invisible “cloud” of approximately 6,000 aerosol particles that could potentially be inhaled by the susceptible conversational partner or others in close proximity”. Assuming this is an approximation of upper limit we may estimate that during one minute talk this supermitter will release ~1,000 particles. It means that according to your measurements ~0.5% could reach the breathing zone of a typical passenger seated directly next to the source, or ~5 particles (for one minute release). For all other passengers it will be 0.02 - 0.03 % or 0.2 – 0.3 particles. Although infectious dose for COVID-19 is not known (at least I am not aware if any published literature data have this info), it might be as low as one particle. Therefore, sitting next to superemitter might not be safe.

1. Asadi, S., et al., The coronavirus pandemic and aerosols: Does COVID-19 transmit via expiratory particles? 2020, Taylor & Francis.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Attachments
Attachment
Submitted filename: Academic Editor Notes to revised version.docx
Revision 2

Editorial Board

PLOS ONE

October 1, 2021

Editorial Board:

I am writing this letter to address the questions and revisions raised by the academic editor and reviewers for our most recent version of the manuscript entitled, “Aerosol tracer testing in Boeing 767 and 777 aircraft to simulate exposure potential of infectious aerosol such as SARS-CoV-2.”

A point-by-point rebuttal appears below, as an appendix, as we did during the last revision. Overall, we attempted to accept, revise, and clarify at each point brought up in the review, and have responded below in blue ink. These changes were all relatively minor but important. We have also updated references that were preprints to their peer-reviewed final versions and fixed some non-Vancouver formatting.

Thank you for your time and consideration.

Sincerely,

Sean Kinahan

National Strategic Research Institute

University of Nebraska Medical Center

42nd and Emile St. Omaha, NE 68198

skinahan@nsri.nebraskaresearch.gov

Tel: 1-443-255-3188

Attachments
Attachment
Submitted filename: Response to Reviewers.docx
Decision Letter - Vladimir Mikheev, Editor

Aerosol tracer testing in Boeing 767 and 777 aircraft to simulate exposure potential of infectious aerosol such as SARS-CoV-2

PONE-D-21-03983R2

Dear Dr. Kinahan,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Vladimir Mikheev

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Dear Dr. Kinahan,

Thank you for submitting the revised version of your manuscript.

I think this manuscript now can be accepted.

I have just one editorial note, please see below.

Thank you,

Vladimir

L122: “to more closely mimic coughing (Supplement)”.

Need to indicate Supplemental Tables Numbers S7 and S8

Also, throughout the text you are using term “Supplemental”, whereas Supplemental File is named as “Supporting Information”. Please be consistent with naming.

Reviewers' comments:

Formally Accepted
Acceptance Letter - Vladimir Mikheev, Editor

PONE-D-21-03983R2

Aerosol tracer testing in Boeing 767 and 777 aircraft to simulate exposure potential of infectious aerosol such as SARS-CoV-2

Dear Dr. Kinahan:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Vladimir Mikheev

Academic Editor

PLOS ONE

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .