Peer Review History
| Original SubmissionJanuary 15, 2020 |
|---|
|
PONE-D-20-01335 Using fluorescence flow cytometry data for single-cell gene expression analysis in bacteria PLOS ONE Dear Prof. van Nimwegen, First of all, let me apologize for the huge delay in reviewing your manuscript. The need for qualified reviews and the recent spread of COVID-19 disease deeply impacted on the review time. After careful reading of past reviewers comments, submission to two additional expert in the field, and my personal evaluation of the manuscript, I feel that it has merit but does not yet fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. In particular, I agree with reviewer 2 that more extensive reference to previous and closely related work should be presented, to better evidence the clearly innovative aspects of your manuscript. We would appreciate receiving your revised manuscript by Jun 18 2020 11:59PM. When you are ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. To enhance the reproducibility of your results, we recommend that if applicable you deposit your laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols Please include the following items when submitting your revised manuscript:
Please note while forming your response, if your article is accepted, you may have the opportunity to make the peer review history publicly available. The record will include editor decision letters (with reviews) and your responses to reviewer comments. If eligible, we will contact you to opt in or out. We look forward to receiving your revised manuscript. Kind regards, Giovanni Signore Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Thank you for stating the following financial disclosure: 'The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.' At this time, please address the following queries:
Please include your amended statements within your cover letter; we will change the online submission form on your behalf. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Partly ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: Galbusera et al, presented a study on the analysis and use of fluorescence flow cytometry data, to study single-cell of bacteria that express a reporter gene at different concentrations. The work is complete and data are sufficient for pubblication. The authors also provide a tool for the measuremnts of atutofluorescence and shot noise of the instrument. However, these results highlight the fact that this technique is not very efficient in the single cell study but rather for the evaluation of the fluorescence signals of an entire bacterial population. The title may mislead the reader who expects to find a single cell analysis approach. I suggest to clarify this point in the title or in the main text. Reviewer #2: Despite the fact that flow cytometry has been used to quantify gene expression variability in bacteria for almost 20 years now, very little work has been done to systematically analyze the measurement errors in cell size and fluorescence that flow cytometers introduce. It is nice to see that the work presented in this manuscript aims to cover this important gap in our knowledge. Measuring size and fluorescence of bacteria is no mean feat, as bacterial cells are typically at the limit of detection for flow cytometers. The authors present a plethora of tests and comparisons between flow cytometry and microscopy-based measurements to discover 1) how to interpret flow cytometry signals related to cell size and fluorescence and 2) how to correct them for biases and measurement noise (whenever possible). Below is a list of the main topics addressed by the authors and my comments about them: 1. Choice of signal parameters to monitor: pulse width is typically used to discriminate single particles from doublets. I am therefore not surprised that this parameter is not particularly informative for fluorescence quantification. It is reassuring that the area is proportional to the product of pulse height and width for the calibration beads. Does a similar connection hold for bacterial cells as well? 2. Gating events based on the scatter measurements: in various ways, this is routinely done by several groups that practice flow cytometry, either in a manual or semi-automatic manner. Does the approach proposed by the authors have any significant advantages? 3. Correlation of FSC and SSC with mean cell size: here, the authors are missing an important citation (Volkmer & Heinemann, PLoS ONE, 2011). That work also made a comparison between mean FSC/SSC and cell volume, with very similar conclusions to the ones made here. 4. Use of FSC/SSC to measure individual cell sizes: the authors conclude that FSC/SSC signals do not carry enough information to measure cell size distributions in an E. coli population. Though I would tend to agree with this conclusion, I do not fully agree with the arguments provided. The authors apply equations (1) and (2) both to microscopy and flow cytometry data. While it is clear to me that (1) and (2) are perfectly adequate for size measurements based on microscopy, I am not sure that they apply just as easily in the case of flow cytometry. Specifically, eq. (1) could perhaps look like x_m = f(x_t)+epsilon, i.e. the relationship between measured and actual sizes could be nonlinear at worst, or linear (perhaps with an offset) at best. In either case, the variance of x_m for flow cytometry will not obey (2), even in the simplest scenario of linear scaling without offset. I think that, before attempting to decompose the measured variance of the flow cytometry signals, the authors should first infer the relationship between x_m and x_t in the case of flow cytometry, for example by using calibration beads of different sizes. Then, using variance propagation they could estimate var(x_t) based on var(x_m) and determine how much information the FSC/SSC signals carry about the size of single cells. Another point regarding the analysis of this section is that one should probably also suspect the noise in GFP measurements as another source of error. As the authors show later on, the GFP signal requires some significant corrections to correctly report the variability of the cell population. On the other hand, it seems to me that the GFP signals used in Fig. 4 were not corrected for shot noise and autofluorescence. It is therefore plausible that the lack of correlation between GFP and FSC/SSC can be partially attributed to the GFP noise. 5. Gating the fluorescence data & 6. Estimating autofluorescence: the authors perform an analysis which is typically carried out in one or another way by practioners of flow cytometry. However, their approach looks quite principled and systematic (e.g. in the averaging of authofluorescence measurements from different dates). 7. Calibration of fluorescence signal to remove shot noise and autofluorescence: here, the authors perform a nice analysis to remove the additional variability introduced by flow cytometry using calibration beads (an approach similar to what I suggested above for the FSC/SCC analysis), and are eventually able to achieve relatively good agreement between microscopy and flow cytometry measurements. I would have preferred to also see the relative, besides the absolute error in the CV’s, to better understand over which range of GFP concentrations the flow cytometry measurements can provide a reliable estimate of the GFP variability. Overall, I think that the authors should try to clarify a bit more which steps of their calibration pipeline differ or improve upon procedures carried out by other groups. For example, the fitting of mixture models is also doable with commercially available flow cytometry software, as well as with user-generated code. I would recommend that they revisit the analysis of FSC/SSC and individual cell size. Some further minor points and questions: - Strains and growth conditions section (M&M) needs some streamlining to better organize the information. Growth media, precultures and dilutions are a bit mixed up for flow cytometry and microscopy experiments, and a bit hard to follow. - Fig. 3: would it be possible that the authors repeat some of the information of ref. 31 about the medium conditions? For example, what does “salt” mean? How are cells grown in these different media? (is growth balanced, for example?) - Fig. 4: what are the units of the horizontal axis in the second and third rows? The scattering units used here are different from those of other figures where scatters are displayed. - Fig. 5: is it correct that the two strains mentioned here are simply the same background strain carrying two different plasmids? - Fig. S6: I do not understand the x-axis title (mean log (GFP.H)). ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files to be viewed.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email us at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
Using fluorescence flow cytometry data for single-cell gene expression analysis in bacteria PONE-D-20-01335R1 Dear Dr. van Nimwegen, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Giovanni Signore Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors addressed all the points raised by reviewers and I think that now the work can be published on PlosOne Reviewer #2: i would like to thank the authors for addressing all my comments and modifying their manuscript accordingly. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No |
| Formally Accepted |
|
PONE-D-20-01335R1 Using fluorescence flow cytometry data for single-cell gene expression analysis in bacteria Dear Dr. van Nimwegen: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Giovanni Signore Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .