Peer Review History
| Original SubmissionMay 24, 2020 |
|---|
|
PONE-D-20-15554 Slit-based Irrigation Catheters can Reduce Procedure-related Ischemic Stroke in Atrial Fibrillation Patients Undergoing Radiofrequency Catheter Ablation PLOS ONE Dear Dr. Shim Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Sep 03 2020 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols We look forward to receiving your revised manuscript. Kind regards, Giuseppe Coppola Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. In your Methods section, please state the date(s) upon which the data source was accessed. 3. Please amend your list of authors on the manuscript to ensure that each author is linked to an affiliation. Authors’ affiliations should reflect the institution where the work was done (if authors moved subsequently, you can also list the new affiliation stating “current affiliation:….” as necessary). [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Partly Reviewer #2: Partly Reviewer #3: No ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: I Don't Know Reviewer #3: Yes ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes Reviewer #3: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The manuscript is quite interesting, BUT there is a big problem between what it is stated in the text and what one can read in table 3. For instance, in the text it is said that "slit - based" had "higher prevalence of SEC", but in table 3 incidence in slit based is 17% and in other is 21.5% (exatcly the opposite!). Another important issue is that "other catheters" were less anticoagulated BEFORE ablation (55.6% vs 67.3%) and remained less anticoagulated AFTER ablation (93.5% vs 97.2%) and both values were statistically signiticant. Finally, incidence of vascular diseases was almost twice as high in "other catheters" group. This point should be highlighted in the discussion Thus, or there is some mistake in the table or this could represent an important bias in judging superiority of the slit-based catheters. Authors must explain this discrepance. Reviewer #2: Kim et al present the results of a retrospective study of peri-procedural ischemic stroke in 3120 patients undergoing first RF catheter ablation at a single center over 20 years. They conclude that use of slit-based irrigated catheters was associated with a lower incidence of ischemic stroke, and this was independent of other risk factors in multivariate analysis. Questions and comments: --How do the authors account for the possibility of changes in operative technique over the 20+ year period of analysis? If non-irrigated catheters were used predominantly in the early years, followed by non-slit-based irrigated catheters, followed by irrigated catheters, there might have been other differences that were not accounted for but correlated with the type of irrigation. For example, was the ACT target identical from 1998 to 2009? Was the timing of the heparin bolus the same, or did operators wait until after transseptal access was achieved in the early years? Was perioperative oral anticoagulation completely constant over this long time period? Were any changes made to sheath aspiration/flush technique, or number/type of diagnostic catheters? How many ablation catheters incorporated contact-force sensing? Was there a difference in warfarin vs NOAC use? --Why do authors lump together internally irrigated catheters and external non-slit-based irrigation catheters? These are very different designs, in fact more dissimilar than slit-based and non-slit-based irrigation catheters, and it seems unwarranted to include them in a single group for analysis. --How many of the 17 ischemic complications occurred >24 hours after the ablation procedure? --What proportion of patients in the non-irrigated, non-slit-based irrigated and slit-based irrigated groups had substrate ablation in addition to PVI? Why was substrate ablation not included as a variable in the multivariate model presented in Table 4? --The text says the slit-based irrigated group had higher prevalence of SEC, but Table 3 says it was lower. Which is correct? Why was SEC not included as a variable in the multivariate model presented in Table 4? --Since irrigated catheters are no longer used for AF ablation, and the slit-based irrigated catheters analyzed here (CoolFlex and Flexability) do not incorporate contact-force sensing, the Discussion should include some comment on the trade-off of giving up contact-force sensing for slit-based irrigation, including new lesion metrics (Ablation Index, Lesion Size Index) that rely on these catheters. Reviewer #3: The authors use a retrospective analysis of a single center large database to provide data that slit-like irrigation is associated with reduced rates of thromboembolic complications following AF ablation compared to other irrigated and non-irrigated catheters. The overall number of patients undergoing ablation is large, although this database spans 20 years of practice with a number of systematic changes over time. Stroke or TIA occurred significantly less with irrigated catheters than non-irrigated catheters. More importantly, slit-like irrigation appeared to be associated with less events compared to non-slit irrigation catheters despite similar number of cases. If true, this is an important observation. The major limitation is the contemporaneous changes in clinical practice, especially anticoagulation during the 20 years of analysis. As practice evolves, often a whole-system change occurs at a center making one catheter and non-fluoroscopic mapping system dominant for a particular time. This can make an untended impact on outcomes in a retrospective analysis like this. Specifically, the introduction and use of uninterrupted anticoagulation during this period. Specifically, the number of patients undergoing ablation with uninterrupted anticoagulation needs to be very similar between groups of irrigated catheters for any confidence that there is a real difference in the irrigation architecture as a mechanism of the difference in outcome. If this cannot be assured, it becomes very difficult to know if the difference should drive changes in practice. The number of outcomes are very small. As such, a small difference in confounding practice (like OAC use during the procedure) can have a major impact. As such, the authors need to make it clear if the catheter types, especially the different irrigated catheters, were used at the same time or overlapping time periods. More importantly, a clear analysis of the number of patients undergoing uninterrupted OAC is required. It is recognized that the slit irrigation group had worse risk factors that would confound by making the thromboembolic rates higher in this group. It might also make the authors more likely to use uninterrupted OAC for this group. There are other limitations in this kind of analysis that cannot be clarified including possible systematic differences in the ascertainment of stroke over time in a database. What specific definition of stroke was used as opposed to TIA and mimickers like migraine? Ordinarily TIA is not used as a hard endpoint, although there is only one TIA among the outcomes. Coolflex catheters do not have force measuring capabilities. As such, authors have traded off this function for different irrigation. This raises the importance of the veracity of this data as a change to a slit irrigation ablation eliminates an ablation technology important at many centers. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Giosue Mascioli, MD; FAIAC; FEHRA, FESC Reviewer #2: No Reviewer #3: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
| Revision 1 |
|
Slit-based Irrigation Catheters can Reduce Procedure-related Ischemic Stroke in Atrial Fibrillation Patients Undergoing Radiofrequency Catheter Ablation PONE-D-20-15554R1 Dear Dr. Shim, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Giuseppe Coppola Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #2: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Partly ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The Authors adequately adressed all the issues elicited by the reviewers. Being a retrospective study, not all bias can be solved, but anyhow the results presented after this new analysis are interesting and convincing. In my opinion the manuscript can now be published as it is. Reviewer #2: The authors have submitted a substantially improved version of this manuscript that adequately addresses my concerns. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Giosue Mascioli Reviewer #2: No |
| Formally Accepted |
|
PONE-D-20-15554R1 Slit-based Irrigation Catheters can Reduce Procedure-related Ischemic Stroke in Atrial Fibrillation Patients Undergoing Radiofrequency Catheter Ablation Dear Dr. Shim: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Giuseppe Coppola Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .