Peer Review History

Original SubmissionOctober 23, 2019
Decision Letter - Gorjan Alagic, Editor

PONE-D-19-29328

Attacking quantum key distribution by light injection via ventilation openings

PLOS ONE

Dear Dr. Garcia-Escartin,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

If you decide to submit a revision, please be sure that you have addressed all of the detailed comments of the reviewers below. The issues raised can be addressed with some careful rewriting, and the addition of appropriate analysis and details. Repeating experiments is not necessary.

If you are planning to submit a revision, please let us know.

We would appreciate receiving your revised manuscript by Jan 31 2020 11:59PM. When you are ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter.

To enhance the reproducibility of your results, we recommend that if applicable you deposit your laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). This letter should be uploaded as separate file and labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. This file should be uploaded as separate file and labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. This file should be uploaded as separate file and labeled 'Manuscript'.

Please note while forming your response, if your article is accepted, you may have the opportunity to make the peer review history publicly available. The record will include editor decision letters (with reviews) and your responses to reviewer comments. If eligible, we will contact you to opt in or out.

We look forward to receiving your revised manuscript.

Kind regards,

Gorjan Alagic, Ph.D.

Academic Editor

PLOS ONE

Journal requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

http://www.journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and http://www.journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. In your Data Availability statement, you have not specified where the minimal data set underlying the results described in your manuscript can be found. PLOS defines a study's minimal data set as the underlying data used to reach the conclusions drawn in the manuscript and any additional data required to replicate the reported study findings in their entirety. All PLOS journals require that the minimal data set be made fully available. For more information about our data policy, please see http://journals.plos.org/plosone/s/data-availability.

Upon re-submitting your revised manuscript, please upload your study’s minimal underlying data set as either Supporting Information files or to a stable, public repository and include the relevant URLs, DOIs, or accession numbers within your revised cover letter. For a list of acceptable repositories, please see http://journals.plos.org/plosone/s/data-availability#loc-recommended-repositories. Any potentially identifying patient information must be fully anonymized.

Important: If there are ethical or legal restrictions to sharing your data publicly, please explain these restrictions in detail. Please see our guidelines for more information on what we consider unacceptable restrictions to publicly sharing data: http://journals.plos.org/plosone/s/data-availability#loc-unacceptable-data-access-restrictions. Note that it is not acceptable for the authors to be the sole named individuals responsible for ensuring data access.

We will update your Data Availability statement to reflect the information you provide in your cover letter.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Partly

Reviewer #2: No

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: No

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: No

Reviewer #2: No

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: 1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript is technically sound, however, the reason why I think the data does not go all the way to support their conclusions is in the attached PDF report.

3. Have the authors made all data underlying the findings in their manuscript fully available?

I could not find if this has been done but I am fairly sure that this is merely a formality they either forgot or it was may be not clear that it was required at this stage.

Reviewer #2: In this article, the authors exploit ventilation holes in quantum devices to inject light inside it and either get information or modify the behaviour of the device itself.

In the first part of the article, the authors study a Trojan horse attack performed by injecting light directly into the SMF delay line of a commercial plug-and-play QKD system, thus preventing it from being detected by the photodiode placed at the entrance of the device. In the second part, they attack a simple QRNG prototype with the aim of inducing an imbalance in the detection rate of the two detectors, thus modifying the output statistics.

The idea behind the article is interesting, since it addresses some implementation issues that might completely break the security of the device. However, in my opinion, there are some major points, in the experimental evaluation of the attacks, that make the article, as it is now, unsuitable for publication.

To evaluate the effect of light injection on QKD, the authors shine a collimated laser into the ventilation holes of the Alice part of Clavis 2 QKD system, aiming at the fiber spool used as a delay line, and look at the number of photons just after the spool. By measuring the fraction of photons coupled into the fiber, they get the injection efficiency as a function of the input laser power and they estimate, from the losses of the different components in a typical QKD setting, the number of photons injected into the line going to Bob. An attacker can thus increase the number of photons going from Alice to Bob without being detected. The main problems in this part are:

* there is no description of the properties of the beam used in the injection. Since this article deals with attacks on the implementation, it should contain more information on how this attack can be implemented practically.

* the analysis of the attack considers just the effect of an undetected increase of the mean photon number coming out from Alice. What would change if Eve used a light at a slightly different wavelength, putting a wave-division multiplexer in the channel collecting all the light she injected without affecting the one going to Bob?

* the authors base the analysis on the attack model described in ref [57]. One of the hypothesis in their analysis is that Eve measures her quantum system just after the sifting procedure. This requires her to have a quantum memory, something that is not realistic nowadays.

* the authors show their attack to be effective for laser powers going from 200 to 500 W. While it is true that these powers are realistically achievable, it is not clear that they don't give rise to other issues (like the degradation of the components). I think the authors should be more careful about this point, since it is crucial in their work.

The following section, about the attacks through ventilation holes on a QRNG, is even more problematic. Indeed, the authors just say that injecting light into the QRNG it is possible to bias the statistics of the two detectors, something that is well known. The prototype QRNG they show in the photo is almost 20 years old, so it has nothing to do with current technology in QRNGs. Moreover, there are no data supporting the claims made by the authors (except a generic "we managed to obtaina ratio >80% ...", with no description of the setup used for obtaining it). In order to get something meaningful, the authors should at least compare the statistics obtained with and without the attack, showing explicitly which advantage could an adversary gain with it.

As a summary, the authors address a real security issue in the security of quantum devices, i.e., the accessibility of optical components through ventilation holes, but they don't provide enough evidence on how this could be exploited, now, by an eavesdropper. I think that, before being considered again for publication, the authors should address more carefully all the experimental aspects behind the proposed attacks, focusing on what is feasible with current technology.

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: Yes: Nitin Jain

Reviewer #2: No

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files to be viewed.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email us at figures@plos.org. Please note that Supporting Information files do not need this step.

Attachments
Attachment
Submitted filename: report-injctAttcks.pdf
Revision 1

The response has been uploaded in a pdf file.

Attachments
Attachment
Submitted filename: response.pdf
Decision Letter - Kim-Kwang Raymond Choo, Editor

Attacking quantum key distribution by light injection via ventilation openings

PONE-D-19-29328R1

Dear Dr. Garcia-Escartin,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Kim-Kwang Raymond Choo, Ph.D.

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.

Reviewer #1: All comments have been addressed

Reviewer #2: All comments have been addressed

**********

2. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: The authors have addressed all concerns and revised the manuscript appropriately. I am happy to recommend it for a publication.

Reviewer #2: In their resubmitted version of the article, the authors have answered in a satisfactory way to the remarks of both reviewers. As it is now, the article is suitable for publication.

I have just one small advice: in the answer to the second point of reviewer 2, the authors claim that, "given the low coupling we found in our device, Eve’s best strategy seems to be using also the photons in the legitimate channel". I think that this observation could be included in the main article, since it explains explicitly why the authors decided to study attacks where the injected photons have the same wavelength as the photons used for QKD. However, this is really a minor issue and the authors could decide to ignore it.

**********

7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: Yes: Nitin Jain

Reviewer #2: No

Formally Accepted
Acceptance Letter - Kim-Kwang Raymond Choo, Editor

PONE-D-19-29328R1

Attacking quantum key distribution by light injection via ventilation openings

Dear Dr. Garcia-Escartin:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Cloud Technology Endowed Professor Kim-Kwang Raymond Choo

Academic Editor

PLOS ONE

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .