Peer Review History
| Original SubmissionJanuary 11, 2020 |
|---|
|
PONE-D-20-00985 Spectral-power associations reflect amplitude modulation and within-frequency interactions on the sub-second timescale and cross-frequency interactions on the seconds timescale PLOS ONE Dear Suzuki, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. We would appreciate receiving your revised manuscript by Apr 23 2020 11:59PM. When you are ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. To enhance the reproducibility of your results, we recommend that if applicable you deposit your laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols Please include the following items when submitting your revised manuscript:
Please note while forming your response, if your article is accepted, you may have the opportunity to make the peer review history publicly available. The record will include editor decision letters (with reviews) and your responses to reviewer comments. If eligible, we will contact you to opt in or out. We look forward to receiving your revised manuscript. Kind regards, Vladyslav Vyazovskiy, PhD Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements: 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at http://www.plosone.org/attachments/PLOSOne_formatting_sample_main_body.pdf and http://www.plosone.org/attachments/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. Please provide additional details regarding participant consent. In the Methods section, please ensure that you have specified what type of consent you obtained (for instance, written or verbal) and whether the ethics committee approved this consent procedure. If verbal consent was obtained please state why it was not possible to obtain written consent and how verbal consent was recorded. If your study included minors, state whether you obtained consent from parents or guardians. 3. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Partly Reviewer #2: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: N/A ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: No Reviewer #2: No ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: In this article, the authors present an original method to quantify spectral-power associations and used it to examine the intra- and inter-sites distribution of spectral-power associations in EEG recordings of subjects at rest. Two independent analysis were implemented for fast (sub-second) and slow (seconds) timescales. The authors also reflect about the relevance of their findings and provide some straightforward interpretations. The paper is therefore of relevance in the field of cross-frequency couplings and the analysis of its functional significance. The experiments are well conceived and data analysis and statistics appears sound. I believe this paper will be of interest both to specialist in data processing and experimentalists. I would like to recommend the publication of the manuscript after the authors consider the revision of the points detailed in the attached file. Reviewer #2: In this manuscript, the amplitude modulation and within-frequency interactions on two specific timescales of sub-second and seconds are illustrated using the plots of spectral-power associations. This approach is interesting to me. There are some comments for authors: Major comments: 1) This approach focuses on the methodology to represent the spectral-power association among the recordings of multi-channels current source density in resting eye-close state. Any new findings with clear physiological meanings? There is no conclusion in this manuscript. Conclusions are important for audiences to catch your contributions and finding in this study. 2) A lot of spectral-power association plots are used to illustrate the sub-second and seconds timescale modulations within single site or cross-site. It is interesting that cross-frequency associations within-site represent the amplitude modulation with Δf and the cross-site associations centralized on the diagonal without Δf. These findings are interesting, but it is difficult for audiences to catch your findings if there is no quantitative statements. 3) Only the cross-site association between one of the referenced sites (AFz, Oz, Cz, T7 & T8) and one out of the other electrodes were presented in this manuscript. There are a total 64*63/2 cross-site associations can be observed in the functional connectivity using 64-channel montage. However, it is impossible to illustrate all cross-site associations in this manuscript. My opinion is to develop a quantitative measure for spectral-power association. The quantitative measure benefits to describing your findings and make it possible to conduct further analysis to functional connectivity for different conditions in future works. 4) Only eye-closed state was investigated in this study, I am interested for what kind within-site and sub-second association (as shown in Figure 3) will be presented in compared with the outcome of eye-close condition. If it possible, authors can provide some statements to describe this. 5) In the second paragraph of page 6 for generating phase-scrambled controls authors mentioned “we chose discrete cosign transform, DCT”. Is this statement correct? The full name of DCT should be “discrete cosine transform”, isn’t it? ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Damián Dellavale Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files to be viewed.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email us at figures@plos.org. Please note that Supporting Information files do not need this step.
|
| Revision 1 |
|
Spectral-power associations reflect amplitude modulation and within-frequency interactions on the sub-second timescale and cross-frequency interactions on the seconds timescale PONE-D-20-00985R1 Dear Dr. Suzuki, We are pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it complies with all outstanding technical requirements. Within one week, you will receive an e-mail containing information on the amendments required prior to publication. When all required modifications have been addressed, you will receive a formal acceptance letter and your manuscript will proceed to our production department and be scheduled for publication. Shortly after the formal acceptance letter is sent, an invoice for payment will follow. To ensure an efficient production and billing process, please log into Editorial Manager at https://www.editorialmanager.com/pone/, click the "Update My Information" link at the top of the page, and update your user information. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to enable them to help maximize its impact. If they will be preparing press materials for this manuscript, you must inform our press team as soon as possible and no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. With kind regards, Vladyslav Vyazovskiy, PhD Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: |
| Formally Accepted |
|
PONE-D-20-00985R1 Spectral-power associations reflect amplitude modulation and within-frequency interactions on the sub-second timescale and cross-frequency interactions on the seconds timescale Dear Dr. Suzuki: I am pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please notify them about your upcoming paper at this point, to enable them to help maximize its impact. If they will be preparing press materials for this manuscript, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. For any other questions or concerns, please email plosone@plos.org. Thank you for submitting your work to PLOS ONE. With kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Vladyslav Vyazovskiy Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .