Fig 1.

The preparation process of PS-SA.

More »

Fig 1 Expand

Fig 2.

Schematic diagram of (a) the synthesis of bio-Ab1 and Ru-Ab2; (b) immuno-sandwich complex (PS-SA/bio-Ab1/CEA/Ru-Ab2) and (c) molecular structures of the Ru-COOH dyes.

More »

Fig 2 Expand

Fig 3.

Low magnification SEM images of (a) PS seed particles; (c) PS-M; high magnification SEM images of (b) porous PS-NO2; (d) PS-M; (e) PS-HPG; (f) PS-SA.

More »

Fig 3 Expand

Fig 4.

FTIR spectra curves of (a) porous PS microspheres, (b) PS-NO2, (c) PS-M, (d) PS-HPG, (e) PS-tosyl and (f) PS-SA.

More »

Fig 4 Expand

Fig 5.

(a) TG curves of PS-M and PS-SA; (b) Magnetization curves of PS-M and PS-SA measured at 298K.

Insets: the photographs of PS-SA before and afer magnetic separation by an extemal magnet.

More »

Fig 5 Expand

Fig 6.

Zeta potential results of porous PS microspheres, PS-NO2, PS-M, PS-HPG, PS-tosyl and PS-SA.

More »

Fig 6 Expand

Fig 7.

Calibration curve of ECL intensity (a) full range concentration and (b) low concentrations of CEA (ng/mL).

(c) The blank sample was measured repeatedly 20 times.

More »

Fig 7 Expand

Table 1.

The mean value (CM) and standard deviation (SD) of the blank sample measured repeatedly 20 times.

More »

Table 1 Expand

Table 2.

The comparison of the linear range and detection limit reported method with that of the developed method for the determination of CEA.

More »

Table 2 Expand

Fig 8.

(A) Specificity investigations of the immunosensor for CEA detection.

(a) blank, (b) AFP (300 ng/mL), (c) CA199 (100 U/mL), (d) TSH (50 uIU/mL), (e) PSA (50 ng/mL), (f) CEA (30 ng/mL), (g) CEA (30 ng/mL) + AFP (300 ng/mL), (h) CEA (30 ng/mL) + CA199 (100 U/mL), (i) CEA (30 ng/mL) + TSH (50 uIU/mL), (j) CEA (30 ng/mL) + PSA (50 ng/mL). (B) Thermostability of the PS-SA beads for the detection at 15 ng/mL of CEA. (C) Reproducibility studies of the immunosensor at 5, 100 and 1000 ng/mL of CEA. (D) The batch-to-batch differences in the electrochemiluminescence detection results among the three independent batches of magnetic beads (PS-SA1, PS-SA2, and PS-SA3).

More »

Fig 8 Expand

Fig 9.

The impact of different matrices (artificial serum and PBS) on ECL intensity.

More »

Fig 9 Expand

Table 3.

Comparison of detection results from simulated artificial serum samples using homemade reagents and Elecsys CEA reagent kit.

More »

Table 3 Expand