Fig 1.

Choroidal thickness map and OCT B-scan with segmented layers.

(a) Visualization of the choroidal thickness (BM-CSI) including the choroid’s measured volume of a healthy right eye based on graph search algorithm. Circles indicate the location of the macula. The BM-CSI volume of the whole C-scan is indicated in the bottom left. (b) B-scan, a sagittal cross-section of the posterior eye segment through the retina, choroid and sclera, separated by the layers ILM, BM and CSI (source: Hydra, HuCE-optoLab/BUAS). The image was cut off in the vertical/z-direction for better visualization. The full A-scan length is 1.9 mm. The ILM is the Inner Limiting Membrane, while BM and CSI denote the Bruch’s Membrane and Choroid-Sclera Interface, respectively.

More »

Fig 1 Expand

Fig 2.

Sample screen of our online tool for manual expert segmentation.

According to the consensus between the experts, interconnecting tissues and vessels inside the sclera were ignored while the yellow segmentation line was continued on the side of the optical nerve horizontal. The pre-processing (filtering and histogram equalization) for better contrast during the task was activated in this case by the expert.

More »

Fig 2 Expand

Fig 3.

The calculation of the similarity measure BLD.

First, the minimum “forward” distance between the point and the contour is determined, here marked as (1). Second, among all the points q on with a “inverse” minimum distance , those are selected whose minimal distance is found at the point p. Here, q and are the candidates, with the corresponding distances denoted by (2) and (3). Then, the maximum distance among the candidates, in this case (2), is chosen as . Finally, is defined as the maximum between and , in this example (2). For more details see [30].

More »

Fig 3 Expand

Fig 4.

The robustness of the BLD in comparison to the DC for contour recognition.

Here, the value of the surface delimited by the green contour is the same in both cases: (a) The region which should be recognized is an ellipse (black). (b) While the original contour was not recognized well at all, the DC for such a segmentation has yet the same high value as in (a). Using the BLD, we achieve a fairer evaluation of the segmentation, as the bad contour detection is taken into account and penalized with a higher value of the BLD (which corresponds to a minor similarity).

More »

Fig 4 Expand

Fig 5.

The representations of the intra-rater reliability of experts 1–6 ordered from (a)–(f).

At every pixel position, the difference to the average value of the three available segmentations per rater is calculated. If its absolute value is smaller than a predefined threshold (here set to 20 μm represented by the grey area) then it is counted, i.e. the prediction is considered reliable. Therefore, the narrower and higher the curve, the more reliable the segmentation by the corresponding expert is. The number of counts found within this range is divided by the total number of segmentation points graded by the corresponding expert. By the obtained normalized value IRCj we define the Intra-Rater Coefficient to quantify the reliability of the jth expert.

More »

Fig 5 Expand

Fig 6.

Examples of manual expert segmentation (consistent and less consistent with each other).

Top: Repeatability of (a) expert 2 and (b) expert 5 when segmenting the CSI. Bottom: Comparison of segmentations by (c) experts 3, 4 and 5 and (d) experts 1, 3 and 4. The choroidal area is subdivided in nasal (N)-temporal (T)/x-direction into five equidistant regions (patches) symmetrically around the foveal center: A (foveal region), B (parafoveal region), and C (perifoveal region). Here only cases of right eyes are depicted.

More »

Fig 6 Expand

Fig 7.

The values of the WI calculated for the algorithm and the experts group.

As similarity measures Jaccard, Dice, BLD and diffZ are used.

More »

Fig 7 Expand

Fig 8.

The average displacements of the CSI grouped by experts and algorithm.

The results are obtained by manual segmentation by the six experts and by CRAR (subdivided into the B-scan positions 1, 3, 6, 11, 13, 16, 21 and 23).

More »

Fig 8 Expand

Fig 9.

The average displacements of the CSI grouped by time intervals.

Above: The average displacements of the CSI detected by the expert group (a) and by CRAR (b) grouped by time intervals between the two measurements and subdivided into eight scan positions. Below: The average displacements of the CSI detected by the expert group (c) and by CRAR (d) grouped by time interval and subdivided in nasal-temporal/x-direction into five equidistant regions C-B-A-B-C (patches) symmetrically distributed around the foveal center, see Fig 6.

More »

Fig 9 Expand

Table 1.

The averaged vertical displacements Δz measured at different time intervals.

More »

Table 1 Expand

Table 2.

The vertical displacements Δz averaged per choroidal subregion.

More »

Table 2 Expand