Fig 1.

Yee lattice with positions of various field components.

The components of the electric field are in the middle of the edges and the components of the magnetic fields are in the centre of the faces. ©1966 IEEE. Reprinted, with permission, from [21].

More »

Fig 1 Expand

Fig 2.

Frequency spectrum for pulses of different lengths, fitted with a Gaussian curve.

In black the simulated pulse, in red the Gaussian fit. It is possible to notice that the broader spectrum is not a perfect Gaussian; this is due to the numerical dispersion being more pronounced in a source with a bigger frequency range.

More »

Fig 2 Expand

Fig 3.

Refractive index of a water-sucrose solution as a function of the sucrose concentration at 589.3 nm [27].

In this work we are assuming that it is possible to translate the data to obtain values for different wavelengths.

More »

Fig 3 Expand

Fig 4.

Peripheral nerve.

Right: schematic structure of a nerve. Left: Xenopus Laevis’ sciatic nerve cross section [28]. It is possible to see how this nerve is made of a single bundle of axons surrounded by the perineum and loose epineurium.

More »

Fig 4 Expand

Fig 5.

Simulation domain for the nerve model.

More »

Fig 5 Expand

Table 1.

Tissues refractive indexes used for the simulation.

It was not possible to obtain all the values for the specific specimen considered (Xenopus laevis), therefore some assumptions (discussed in the text) have been made.

More »

Table 1 Expand

Table 2.

Parameters used for the simulations.

More »

Table 2 Expand

Fig 6.

OCT signal for source with a σλ ∼ 76 nm.

The top panel shows the intensity OCT signal in arbitrary units, in this figure it is possible to discern the various elements inside the tissues: epineurium, elastic fibres and axons are labelled. The bottom panel shows the difference between the intensity OCT signals obtained from the simulations for the inactive and active nerves normalised to the intensity of the incoming light. It is noticeable that, as expected, the change in signal is only due to the change in refractive index of the axons. The axons themselves are not discernible because the resolution is not high enough. The zero has been placed at the interface between water and epineurium and the grey shadowed area represents the poisson noise.

More »

Fig 6 Expand

Fig 7.

OCT signal for source with a σλ ∼ 13 nm.

The top panel shows the intensity OCT signal in arbitrary units, in this it is not possible to discern all the various elements inside the tissues, as the resolution is not high enough. The bottom panel shows the difference between the intensity OCT signals obtained from the simulations for the inactive and active nerves normalised to the intensity of the incoming light. It is noticeable that, as expected, the change in signal is only due to the change in refractive index of the axons. The zero has been placed at the interface between water and epineurium and the grey shadowed area represents the poisson noise.

More »

Fig 7 Expand

Fig 8.

OCT signal for different concentrations of water-sucrose solutions and σλ ∼ 76 nm.

Top panel: signal obtained for the glass rods model with a water-sucrose solution at 0.1%. Other panels: difference between the signal obtained from different concentrations (0.1%, 0.01% and 0.001% respectively) and pure water normalised to the intensity of the incoming light. The grey shadowed area represents the poisson noise.

More »

Fig 8 Expand

Fig 9.

Transmission coefficient calculated theoretically using Fresnel equations (red line) and from the simulations (blue points).

More »

Fig 9 Expand