Fig 1.

Animal model and electric field distribution After sterile thoracotomy, IRE was applied to the anterior myocardium located to the left of the lower part of the left anterior descending artery (Fig 1.1 and Fig 1.2).

Electric field distribution induced by two-needle electrodes and a 500 volt pulse are illustrated in Fig 1.3. Note that electric field intensity is concentrated in the plane between the two electrodes.

More »

Fig 1 Expand

Table 1.

Electroporation protocols used in the study.

More »

Table 1 Expand

Fig 2.

Average ejection fraction of various study groups during the study period.

The vertical axis stands for ejection fraction (EF) in %. The horizontal axis stands for time point during the study. Each group was treated with a different IRE protocol. Note that the reduction in EF was demonstrated in all the protocols. Some of the groups demonstrated some recovery in EF between day 7 and day 28. Some of the IRE protocols caused more severe damage than the anterior MI group (protocol 8).

More »

Fig 2 Expand

Fig 3.

Comparison of morphometric measurements between pairs of protocols.

Morphometric measurements of pairs of protocols with only one changed parameter were compared (using unpaired Student t-test), in order to learn about the effect of different parameters on the potency of each protocol. Only pairs with a statistically significant difference in morphometric measurements are shown. From top to bottom: (3a) presents comparisons of scar areas with significant differences. (3b) presents comparisons of scar thicknesses with significant differences. (3c) presents comparisons of scar perimeters with significant differences.

More »

Fig 3 Expand

Fig 4.

Microscopic view of collagen staining of rat hearts.

The collagen staining demonstrates the presence of extended scar tissue in the myocardium that has been treated by IRE. The control slide (left figure) lacks bluish coloring because of lack of scar. In the right figure, the bluish coloring demonstrates well the typical scaring caused by IRE as was observed in our study.

More »

Fig 4 Expand

Fig 5.

Comparison of myocardial axial section of different protocols.

Every row in the figure compares the axial section of the left ventricle of rats that were treated with two different IRE protocols. Moreover, all the pairs of protocols selected for this figure are different in only one setting of the IRE protocols (i.e. voltage, frequency, etc.) and demonstrate significant differences between their morphometric measurements. Protocol numbers are in the right upper corner of each slide. The pairs of protocols are (from top to bottom): 5 and 3(70μsec and 100μsec), 8 and 3 (MI vs. IRE), 6 and 4 (10 pulses vs. 20 pulses), 5 and 4 (2Hz vs. 1HZ).

More »

Fig 5 Expand

Fig 6.

Microscopic view of treated myocardium.

In each row the images from right to left represent: low potency IRE protocol (protocol 2), high potency electroporation protocol (protocol 6), MI group (protocol 8). ED1 staining is presented in the upper row, while H&E staining is presented in the lower row. Note: 1) the similar extent of damage between high potency IRE protocol and MI–images 1B and 1C, 2B and 2C. 2). The greater degree of extracellular damage caused by MI compared with low and high potency IRE protocols–images 2C, 2A, 2B respectively. Arrows point to the areas of extensive inflammation.

More »

Fig 6 Expand

Table 2.

Summary of echocardiographic measurements.

More »

Table 2 Expand

Table 3.

Comparison of changes in ejection fraction between protocols.

More »

Table 3 Expand