Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

< Back to Article

Table 1.

Clinical characteristic of the study groups.

More »

Table 1 Expand

Table 2.

SWV, ACR, and BMP-7 in the study groups(Median (Q1, Q3)).

More »

Table 2 Expand

Fig 1.

Comparison of SWV and BMP-7 between the groups.

*Compared with the control group, P < 0.01; #compared with the normo- group, P < 0.01; $compared with the micro- group, P < 0.01. Both the micro- and macro- groups had a significantly higher SWV and lower BMP-7 compared to the normo- group (P < 0.01). SWV, shear wave velocity; BMP-7, bone morphogenetic protein-7; control, control group; normo-, normal albuminuria; micro-, microalbuminuria; macro-, macroalbuminuria.

More »

Fig 1 Expand

Fig 2.

Shear wave velocity measurements.

A Siemens ACUSON S2000 US system (Siemens, Germany) equipped with a 3.5–5.5 MHz linear array transducer (4C1) was used for the measurements. After measuring the cortex and medulla thicknesses in the lower pole of the kidney (the perpendicular distance from the apex of the pyramid to the capsule of the kidney), an acoustic push pulse was transmitted immediately in the region of interest (box with fixed dimensions of 1 cm × 0.5 cm). Three valid measurements were obtained for each kidney at the same portion of the mid-pole, as parallel as possible to the radically arranged tubular system. The results are expressed as meters per second (m/sec).

More »

Fig 2 Expand

Fig 3.

Correlation between SWV and BMP-7 in DKD subjects.

SWV, shear wave velocity; BMP-7, bone morphogenetic protein-7; r = -0.569; P < 0.05; linear regression equation: y = -38.127x + 159.641.

More »

Fig 3 Expand