Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

< Back to Article

Figure 1.

Thresholding reaction of a DNA neuron.

More »

Figure 1 Expand

Figure 2.

Irreversible DNA strand displacement.

More »

Figure 2 Expand

Figure 3.

Abstract diagrams of implementation of a DNA neuron with AND logic.

More »

Figure 3 Expand

Figure 4.

HEX and FAM fluorescent probes to detect the output spike “1/0” of DNA Neuron.

More »

Figure 4 Expand

Figure 5.

Abstract diagrams of two DNA neurons executing XOR logic.

More »

Figure 5 Expand

Figure 6.

Visual DSD simulations of AND logic gate with input signal “00”.

More »

Figure 6 Expand

Figure 7.

Visual DSD simulations of AND logic gate with input signal “01”.

More »

Figure 7 Expand

Figure 8.

Visual DSD simulations of AND logic gate with input signal “11”.

More »

Figure 8 Expand

Figure 9.

Visual DSD simulations of XOR logic gate with input signal “00”.

More »

Figure 9 Expand

Figure 10.

Visual DSD simulations of XOR logic gate with input signal “01”.

More »

Figure 10 Expand

Figure 11.

Visual DSD simulations of XOR logic gate with input signal “11”.

More »

Figure 11 Expand

Table 1.

The detailed amounts of involved DNA molecules in XOR logic gate.

More »

Table 1 Expand

Figure 12.

Fluorescence spectra of 6-FAM(FITC) and HEX.

More »

Figure 12 Expand

Table 2.

All Oligonucleotides for “DNA neurons”.

More »

Table 2 Expand

Table 3.

Domains of “DNA neurons”.

More »

Table 3 Expand

Table 4.

Components samples.

More »

Table 4 Expand

Table 5.

Probes with Fluorophores.

More »

Table 5 Expand

Figure 13.

Fluoroscence data of DNA Neurons execute AND logic with input “00”.

The X-axis is cycling time of Real-time PCR, the time span of each cycle is 10 minutes, temperature of each cycle keeps in 24–25°C. The Y-axis is relative intensity of HEX (red curve) and FAM (blue curve).

More »

Figure 13 Expand

Figure 14.

Fluoroscence data of DNA Neurons execute AND logic with input “01”.

The X-axis is cycling time of Real-time PCR, the time span of each cycle is 10 minutes, temperature of each cycle keeps in 24–25°C. The Y-axis is relative intensity of HEX (red curve) and FAM (blue curve).

More »

Figure 14 Expand

Figure 15.

Fluoroscence data of DNA Neurons execute AND logic with input “11”.

The X-axis is cycling time of Real-time PCR, the time span of each cycle is 10 minutes, temperature of each cycle keeps in 24–25°C. The Y-axis is relative intensity of HEX (red curve) and FAM (blue curve).

More »

Figure 15 Expand

Figure 16.

Fluoroscence data of DNA Neurons execute XOR logic with input “00”.

The X-axis is cycling time of Real-time PCR, the time span of each cycle is 10 minutes, temperature of each cycle keeps in 24–25°C. The Y-axis is relative intensity of HEX (red curve) and FAM (blue curve).

More »

Figure 16 Expand

Figure 17.

Fluoroscence data of DNA Neurons execute XOR logic with input “01”.

The X-axis is cycling time of Real-time PCR, the time span of each cycle is 10 minutes, temperature of each cycle keeps in 24–25°C. The Y-axis is relative intensity of HEX (red curve) and FAM (blue curve).

More »

Figure 17 Expand

Figure 18.

Fluoroscence data of DNA Neurons execute XOR logic with input “11”.

The X-axis is cycling time of Real-time PCR, the time span of each cycle is 10 minutes, temperature of each cycle keeps in 24–25°C. The Y-axis is relative intensity of HEX (red curve) and FAM (blue curve).

More »

Figure 18 Expand