Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

< Back to Article

Figure 1.

HT-PBNA protocol.

Assay plate preparation (A) and neutralization assay (B) are separated. In a first step, serial dilutions of serum samples are performed on one dilution plate. Identical assay plates are generated by transferring the dilutions to multiple replica-assay plates which can be stored at −20°C. In the second step, the neutralization assay is carried out in a add-on format using the previously prepared assay plates. A) Assay plate preparation. Sera are transferred from a 96 well storage in SBS standard to a 384 well polypropylene V-bottom plate for serial dilution with a pipetting robot in cell culture medium. Finally the serially diluted sera are transferred with the same pipetting robot to each of 3*n white 384 well cell culture assay plates (n = number of PV-types). The plates are sealed immediately with a cover foil and stored at −20°C until their use in the PBNA. B) Assay assembly and read out. Assay plates are thawed and pseudovirions followed by reporter cells are added with a bulk dispenser. Three identical assay plates originating from the same serum dilution plate are used for each PV- type. After 2 days of incubation the luminescence from the Gaussia reporter is read directly in the assay plates. Inhibition (%) is calculated by normalization of the luminescence to the mean of the negative control wells without serum present on each plate. The median of the triplicate values is used for the calculation of the ED50-value (effective dilution giving 50% inhibition) for each serum according to the four parameter logistic curve fit model y = A+(B−A)/(1+(C/x)D).

More »

Figure 1 Expand

Figure 2.

Influence of cell density on Gaussia luciferase activity.

HeLaT clone 4 cells were seeded at the indicated densities into white 384 well plates containing HPV 16°C for 2 days substrate for the Gaussia luciferase or ATPLite1step™ was added and the luminescence measured. Columns show the median luminescence of 64 wells with bars indicating the standard deviation.

More »

Figure 2 Expand

Figure 3.

Titration of different PSV preparations.

Serial dilution of PSV preparations from HPV types 16, 18, 31, 45, 52, 58 and BPV-1 were assayed for Gaussia luciferase activity in the HT-PBNA. For HPV types 16 and 18 a second PSV preparation is indicated by an asterisk (*). Luminescence signals are expressed as relative light units (RLU). The titers for undiluted HPV 16, 18, and BPV-1 PSV were 3.0×109, 3.9×109, 1.1×1010 genomes per ml, respectively.

More »

Figure 3 Expand

Figure 4.

Influence of PSV concentration on HT-PBNA analytical sensitivity and robustness.

Neutralization titers of a serum from a Gardasil® immunized individual expressed as ED50 values (open circles and open squares) with the variability (bars indicating the 95% confidence intervals) were determined at different PSV concentrations. The maximal luminescence intensities (RLU) obtained without serum are shown as crosses. An arrow indicates the dilution of the PSV preparation that was used in subsequent neutralization assays.

More »

Figure 4 Expand

Figure 5.

Effect of PSV-serum premix incubation time on neutralization titer.

A serum from a Gardasil® vaccinated individual was pre-incubated for different times with HPV 16 or HPV 18 PSVs before the neutralization assay was initiated by the addition of reporter cells. ED50 values with 95% confidence intervals are shown.

More »

Figure 5 Expand

Figure 6.

HT-PBNA inter- and intra-run variability of neutralization titers.

The ED50 values for HPV 16 and HPV 18 PSV of the serum standard were determined in 58 repeats on seven assay days (runs) over a period of 2 months. For six of the 7 assay days, triplicates of the standard serum dilutions were assayed 8 times each, for one assay date the standard serum was assayed 10 times.

More »

Figure 6 Expand

Figure 7.

Analytical sensitivity and type-specificity of the HPV 16 and HPV 18 HT-PBNA.

Titration of the WHO International Standards for antibodies to HPV 16 (left) and HPV 18 (right) in HT-PBNA using PSV of HPV types 16, 18, 31, 45, 52, 58 and BPV-1.

More »

Figure 7 Expand

Figure 8.

Detection of neutralizing antibodies as result of natural infection by HT-PBNA.

Thirty-five pre-vaccination sera from a study involving patients with CIN2+ lesions were tested for neutralizing antibodies against PSVs of HPV types 16, 18 and 31. The geometrical mean titer for each HPV type is indicated as a horizontal line and the cut off value (ED50 = 80) as a dashed line.

More »

Figure 8 Expand

Figure 9.

Comparison of HPV 16 HT-PBNA (Gaussia) with manPBNA (SEAP and Gaussia) and GST-HPV 16 L1 antibody binding assay for natural and vaccine-induced HPV16-specific responses.

HPV 16 HT-PBNA (A–D), manPBNA using SEAP reporter (A and B; titers, ED50) and a bead-based GST-HPV 16 L1 antibody binding assay (C and D; median fluorescent intensity (MFI) at 1∶100 or 1∶2700 serum dilution) were used to determine reactivity of pre- (n = 35; A and C) and post-vaccination (n = 72; B and D) sera. Serum samples analyzed were from women with HPV 16 positive, high-grade cervical intraepithelial neoplasia (base-line sera of the chimeric HPV 16 L1-E7 vaccination trial). Cut off values used for positive/negative classification (broken lines in C) were an ED50 of 80 for the HT-PBNA and 109 MFI at 1∶100 for the GST-L1 antibody binding assay.

More »

Figure 9 Expand

Figure 10.

Titration of vaccine sera in the HT-PBNA using PSV of HPV types 16, 18, 31, 45, 52, 58 and BPV-1. A

) Standard serum from Gardasil® vaccinated person. B) Cervarix® vaccine serum. C) Serum from a mouse immunized with L2 epitopes (amino acids 17–36) from HPV16 inserted in the capsid of adeno-associated virus 2 particles.

More »

Figure 10 Expand