Figure 1.
Demonstration stimulus for the Helmholtz-Kohlrausch effect.
Top: Example of a stimulus used to measure the relationship between reflectance, luminance and brightness. Bottom: The wedge most frequently selected by subjects as the best match to the brightness of the blue dot. The wedges that are equally radiant and equally luminant with the blue dot are also indicated.
Figure 2.
The Bayesian ideal observer predictions of reflectance.
A) Predictions of reflectance as σ (the physical correlate of saturation) varies, for a constant luminance. Low saturation surfaces lead to low predictions of reflectance, and high saturation to high predictions of reflectance. Error bars indicate 1 standard error. B) Predictions of reflectance as μ (the physical correlate of hue) varies, for a constant luminance. The ideal observer predictions of reflectance for different dominant wavelengths, grouped by low (L, 0.013), medium (M, 0.051) and high (H, 0.14) luminance values. This shows that for any given luminance, yellows and greens are seen as less reflective than blues and reds. Error bars indicate 1 standard error.
Figure 3.
Ideal observer predictions when training scenes with altered scene or image statistics.
A) Ideal observer predictions when training scenes are biased towards “green”. The training set of SRFs is a mixture of 3 Gaussians as before, but here one component is forced to be centred at 550 nm, which typically appears green. For comparison, the previous “default” results from Figure 2B are shown using dotted lines. B) Ideal observer predictions when training scenes are biased towards “red” and “blue”. The training set SRFs are still a mixture of 3 Gaussians as before, but here one component is forced to be centred at either 450 nm (“blue”) or 650 nm (“red”) for each surface. For comparison, the previous “default” results are shown using dotted lines. C) Ideal observer predictions with increased M λ-max. The M-cone peak sensitivity is now 560 nm on both training and test sets, instead of the usual 545 nm. For comparison, the previous “default” results are shown using dotted lines. D) Ideal observer predictions with decreased M λ-max. The M-cone peak sensitivity is now 505 nm on both training and test sets, instead of the usual 545 nm. This is mid-way between L-cone and S-cone λ-max values. For comparison, the previous “default” results are shown using dotted lines.
Figure 4.
Ideal observer predictions with a green-absorbing filter.
A) Ideal observer predictions when trained with a green-absorbing filter and tested with the same filter on the standard test set. For comparison, the previous “default” results are shown using dotted lines. The predictions are now smaller, but follow the same overall pattern. B) Ideal observer predictions when trained with a green-absorbing filter and tested on the “unfiltered” standard test set. For comparison, the previous “default” results are shown using dotted lines. The predictions now follow a very different pattern.
Figure 5.
fMRI experiments: stimuli and results.
Top row: The blue standard (left), equiluminant yellow (middle), and equally bright (right) annuli used in the first fMRI experiment; the relative responses (percent signal change) of primary visual cortex (V1) to the these stimuli (in the same left-to-right order as shown in the left panels) are shown on the right for two subjects (S1, S2). Error bars indicate one standard error. Bottom row: Blue standard (left), equiluminant low-saturated blue (middle), and equally bright low-saturated blue (right) annuli used in the second fMRI experiment; again the relative response of primary visual cortex (V1) of two subjects to these stimuli are indicated on the right (S2, S3). Display conventions are as for the upper row. Evidently V1 activity is consistent with the probable image-source relationship rather than the characteristics of the stimuli as such.
Figure 6.
Relationship between luminance, object reflectance and colour percepts.
Left: The yellow and blue objects reflect the same quantity of light and appear equally bright to observers. However, due to the lower sensitivity of the retina to shorter wavelengths, the stimuli arising from the two objects elicit very different luminance signals. Right: A darker yellow object reflects less light but generates the same luminance signal as the blue object. It nonetheless appears less bright than the blue object.
Figure 7.
Three example Gaussian spectral power distributions.
The standard deviation of the intensity (y-axis) of the three curves are the physical correlates of the perceived saturation of the corresponding spectra, with the highest on the left and the lowest on the right. The area under each curve (i.e. the reflectivity) is constant.