Reader Comments

Post a new comment on this article

Possible error in table 1

Posted by awales462 on 23 Mar 2021 at 15:23 GMT

The MIC50 and MIC90 values for benzalkonium chloride and Salmonella spp. in table 1 (both given as 16 mg/L) are not consistent with the graphed MIC values in Figs 1 and 4. Suspect correct values are: MIC50 = 32 mg/L and MIC90 = 64 mg/L.

No competing interests declared.

RE: Possible error in table 1

jmartinez148 replied to awales462 on 25 Mar 2021 at 21:57 GMT

We appreciate the coment. After re-reading the article it is clear that the values written in the table were wrong and the right values are the ones stated in the commentary: MIC50 = 32 mg/L and MIC90 = 64 mg/L. Since these values can be inferred from the Figures, this error at the time of writing the Table that does not alter the content of the article.

No competing interests declared.