Figures
Abstract
Microtubules are filamentous structures that are involved in several important cellular processes, including cell division, cellular structure and mechanics, and intracellular transportation. Little is known about potential differences in microtubule distributions within and across cell lines. Here we describe a method to estimate information pertaining to 3D microtubule distributions from 2D fluorescence images. Our method allows for quantitative comparisons of microtubule distribution parameters (number of microtubules, mean length) between different cell lines. Among eleven cell lines compared, some showed differences that could be accounted for by differences in the total amount of tubulin per cell while others showed statistically significant differences in the balance between number and length of microtubules. We also observed that some cell lines that visually appear different in their microtubule distributions are quite similar when the model parameters are considered. The method is expected to be generally useful for comparing microtubule distributions between cell lines and for a given cell line after various perturbations. The results are also expected to enable analysis of the differences in gene expression underlying the observed differences in microtubule distributions among cell types.
Citation: Li J, Shariff A, Wiking M, Lundberg E, Rohde GK, Murphy RF (2012) Estimating Microtubule Distributions from 2D Immunofluorescence Microscopy Images Reveals Differences among Human Cultured Cell Lines. PLoS ONE 7(11): e50292. https://doi.org/10.1371/journal.pone.0050292
Editor: Jonathan A. Coles, Glasgow University, United Kingdom
Received: April 20, 2012; Accepted: October 22, 2012; Published: November 28, 2012
Copyright: © 2012 Li et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Funding: This work was supported in part by National Institutes of Health (NIH) grants GM090033 (GKR) and GM075205 (RFM) and by the Knut and Alice Wallenberg Foundation. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. No additional external funding was received for this study.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Microtubules play an indispensable role in subcellular processes such as cell movement, cell division and intracellular transportation. In turn, these processes are known to play a role in other biological phenomena such as wound healing, and cancer metastasis. Extracting information about the organization of microtubules in different cell lines could potentially shed light on the roles of microtubule associated proteins in that organization. While limited information is available about variation in microtubule distributions [1], [2], information on those distributions in intact cells for different cell lines has not been readily available. Most microtubule studies have focused on dynamics and interactions with drugs and microtubule associated proteins [3]–[6]. We believe that the ability to obtain reliable estimates of the overall organization of microtubules in whole cells could allow quantification of their dependency on different pertubagens, drugs, mechanical stimuli, etc.
Electron microscopy can be used to trace microtubules, but the specimen preparation for imaging does not allow for intact cells to be imaged. Fluorescence microscopy can be used to image intact cells, but microtubules typically overlap and are often densely packed inside cells. It is very difficult, if not impossible, to manually trace each individual microtubule in a confocal or wide-field fluorescence microscopy image in order to obtain accurate estimates of microtubule distribution parameters. Hence previous work comparing cell lines has often focused on the tips of microtubules where tracing is possible, or the comparison has been only qualitative [7].
We therefore previously developed an indirect method for estimating natural, interpretable and quantitative parameters such as the number and the mean length of microtubules from 3D fluorescence microscopy images of microtubules [8], [9]. These parameters are important because they represent basic biophysical characteristics of tubulin polymerization. The basis of the method is to use a generative model of microtubule patterns (Figure 1) to synthesize 3D images for many values of the model parameters, and then to pick the image that best matches the given real image (and thus to estimate the parameters that could have produced it). Our original method utilized 3D images, but 3D images of intact whole cells are much less commonly available than 2D images. We therefore describe here a method of estimating 3D microtubule model parameters from 2D image fluorescence microscopy images of tubulin. We test our approach on the 3D images of HeLa cells previously used to develop the model, and then use it to compare microtubule distributions in different cell lines.
Each microtubule starts from the centrosome, and randomly grows to the second point on the lateral surface of a cone whose aperture is 2α. Then the microtubule grows the same way until it hits the cell or nuclear shape boundary and is not able to step further within the cytosolic area. At this time, we relax the collinearity requirement but still confine the next direction under the local constraint αlocal. Moreover, we also keep on checking a consecutive multiple (30) steps, and require that there are less than or equal to 3 pairwise vector angles that are larger than the global constraint αglobal. Beginning with an empty (black) cytosolic area (shaped by cell and nuclear boundary), we add one to the intensity of the pixel which a microtubule crosses. In this paper, we used every step of growth to be 0.2 microns (1 pixel). For the two constraints on the collinearity which controls the curvature of each microtubule and the local and global rebounding issues, we used αlocal to be 63.9 degrees and αglobal to be 120 degrees. The figure only illustrates the procedure of growth in 2D for better visualization but can be easily imagined to extend to 3D.
Figure 2 provides an overview of the framework introduced in this paper. There are two sub-systems. One is for generating synthetic images of microtubules, and the other is for estimating the microtubule model parameters for real images through comparison with the synthetic images. We first obtained 2D fluorescence microscopy images for eleven cell lines. Each image contains two channels, one for microtubule staining and the other for nuclear staining. The images are segmented to find individual cell and nuclear boundaries. For each cell, we estimate a Point Spread Function (PSF), centrosome location and single microtubule intensity. On the basis of the segmented 2D cell and nuclear shapes, approximate 3D cell and nuclear morphologies are generated. Given the model (Figure 1) and ranges of allowed values of its parameters (number of microtubules (N), mean of the length distribution (mu) and collinearity (α)), synthetic images of microtubule distributions are generated for each 3D morphology for each combination of allowed parameter values. Each raw synthetic image is then convolved with the estimated PSF and multiplied with the estimated single microtubule intensity to make it comparable to the real image. Numerical features are then calculated on every real cell image and the synthetic images for it. The matching method then selects one set of parameters for which the synthetic image is the closest to the real image in the feature space.
The framework contains two sub-systems, one for generating 3D synthetic images of distributions of microtubules (A), and one for estimating and comparing the model parameters of distribution of microtubules from real 2D images of eleven cell lines (B).
Using this indirect method, we estimate the model parameters for 2D images from eleven human cell lines, and analyze the resulting parameters.
Results
3D Cell and Nuclear Shape Generation from a 2D Slice of Microtubule Channel and Nucleus Channel
In our earlier work, we described an indirect approach to estimate parameters of a generative model of microtubules that was conditioned on the shape of the cell and the nucleus [8]. These shapes were estimated from a 3D confocal stack of images of a total protein stain and a DNA stain respectively. Since the images we analyze in this paper are only 2D slices, we developed an approach to estimate an approximate 3D shape of a cell and nucleus from a 2D slice (purely for the purpose of being able to generate a synthetic microtubule distribution). The location of the centrosome was also estimated (see Methods). Figure 3 shows an example of microtubule and nucleus images and the resulting approximate 3D cell and nucleus shape models (see details in the section of “3D cell and nuclear morphology generation” in Methods). We also describe a method to detect the 3D coordinate of the centrosome from the microtubule image using a two step approach (see Methods). These models and centrosome location were then used to generate microtubules in the cytosolic space.
(A) Example of a real 2D cell image (tubulin channel) and its approximate bottom shape. (B) Cartoon of an X-Z projection of a cell on a substrate. (C) Example of a generated 3D cell shape containing 8 stacks (1.6 microns). (D) Illustration of inputs and outputs for the procedure.
Recovering 3D Microtubule Generative Model Parameters from 2D Images: comparisons with real 3D estimates
To test the accuracy of estimating microtubule parameters from 2D images, we applied our new 2D method (see Methods) using the central slice (at half height of the cell) of 3D HeLa cell images and compared the estimated parameters with those from the 3D method. The half height was chosen as the preferred slice because the 2D images used later were also acquired at half the height of the cell. We computed the mean absolute percentage error (MAPE) in each of the parameters estimated from the 2D images assuming that the estimated parameters from the 3D method were correct. Results are shown in Table 1 for 42 cells. From the table, we can see that the estimates of the number of microtubules and collinearity from a single 2D slice are reasonably close to those from the entire 3D image. However, the MAPE for the mean length appears to be somewhat larger. We will aim to reduce this discrepancy in future work. However, we note that most cells were estimated to have mean length of 10 or 15 microns (see the section of library generation in Methods) using the 3D method on the original 3D images. Therefore a small deviation in the estimates of 5 microns (the increment of the range of allowed values of mean length) would cause a MAPE of 50 or 33. The table also shows a comparison of the true cell heights and the estimated ones, with the results showing that they are reasonably close.
Recovering 3D Microtubule Generative Model Parameters from 2D Images: simulated experiments
We estimated how well our recovery method can perform using simulated images for which the correct parameters were known. For one cell geometry (cell shape and nucleus shape), a library of 3D synthetic images was generated with predefined parameters as a validation bed; then 5 other testing libraries were generated using different random seeds. The predefined parameters for the validation bed were estimated from each testing library separately. The resulting errors are shown in Table 2 and indicate that the system accurately recovers model parameters from 2D slices of synthetic images.
Estimating Microtubule Parameters for Images of Eleven Cell Lines
3D microtubule model parameters were estimated from 2D fluorescence microscopy images of eleven cell lines collected as described previously [1], with the application of the whole framework including library generation, feature calculation and matching (see Methods). This dataset consisted of 112 A-431 cells, 114 from U-2OS cells, 94 U-251MG cells, 38 RT-4 cells, 110 PC-3 cells, 51 Hep-G2 cells, 35 HeLa cells, 77 CaCo2 cells, 66 A-549 cells, 70 Hek-293 cells and 54 MCF-7 cells. Figure 4 shows examples of query images and the corresponding images synthesized using the parameters estimated from them. Note that the synthetic images are not “exactly” the same as the corresponding real ones in every single microtubule, because the goal of the generative models is to learn the underlying distribution of microtubules from which the real images were drawn. Hence from Figure 4, we can see that synthetic images are similar to real ones in terms of the distribution of microtubules. There is an underlying assumption that the cells from the same cell line tend to have some level of consistency in the distribution of microtubules. Therefore, we measured the coefficient of variation (the ratio of the standard deviation to the mean) for the estimated parameters of real cells. The resulting values for the number of microtubules ranged from 0.28 to 0.60 and from 0.21 to 0.43 for the mean of the length distribution. We show the frequency distribution of each of the three parameters for every cell line in Figure 5. It shows that most of the cell lines have quite close to a normal distribution for both the number of microtubules and mean length. Some may deviate a little to have a Gamma distribution-like shape. For the collinearity, due to the computational efficiency, we only used three candidate values in the library of synthetic images, so we cannot draw any significant conclusions. The scatter plot of the two dimensional parameter space (number of microtubules and mean length) estimated from those cell lines is shown in Figure 6. The plot shows the variation in number of microtubules, in mean length and in joint correlation of the two. We will compare them in the next section.
2D real images are shown on the left, and center slices of the best-matching 3D synthetic images are shown on the right. (A) A-431 cell line, Number of microtubules = 250, Mean of length distribution = 30 microns, Collinearity = 0.97000; (B) U-2OS cell line, Number of microtubules = 250, Mean of length distribution = 30 microns, Collinearity = 0.98466; (C) U-251MG cell line, Number of microtubules = 250, Mean of length distribution = 20 microns, Collinearity = 0.99610.
There are two sets of three columns for the model parameters (number of microtubules, mean of the length distribution and collinearity) in each row. The cell lines (from top to bottom) are U-251MG, A-549, MCF-7, Hep-G2, A-431 and HeLa in the left column, and CaCo2, PC-3, RT-4, Hek-293, and U-20S in the right.
The ellipses are centered at the bivariate means of the two parameters and contain about 67% to 80% of the cells for a particular cell line (at most 1.5 standard deviations from the means).
Comparing Microtubule Distributions Across Eleven Cell Lines
Comparing bivariate distributions of the number of microtubules and the mean of length.
We compared the bivariate distribution of the estimated number of microtubules and the mean of length across different cell lines. We first compared the covariances using Box's M test. The p-value for this comparison was≈0 which indicates that we can readily reject the null hypothesis of homogeneity of covariances. Next, we used the pairwise Hotelling's T2 test to test whether there were significant differences between the bivariate means of the distributions between cell lines. Because there is strong imbalance of the number of cells among different cell lines, we repeated the pairwise testing 100 times each for subsamples of 35 cells (the minimum number of cells for a cell line) for every cell line and then the minimum p-values from the repeats (after Bonferroni correction) were reported. All the pairwise p-values were then adjusted using family-wise Bonferroni correction for multiple testing [10]. We show the p-values in the lower triangular part of Table 3, and the ones denoted with “*” indicate significant differences. In addition, given the Hotelling's T2 statistics, we built a hierarchical clustering tree shown in Figure 7 (A), and the rows and columns of the lower triangular part of Table 3 are sorted according to the tree.
The trees were built on the pairwise Hotelling's T2 statistics from (A) the testing of the bivariate distributions of the estimated number of microtubules and mean length and (B) from the testing of the bivariate distributions of the first two principal components of the multivariate features computed from the real images.
Comparing multivariate distributions of numerical features on real images.
As a comparison to these statistical tests of indirect parameter estimates, we repeated the calculations mentioned above using features calculated directly from real cell images. We used the first two principal components, which accounted for 99.99% of the total variance in feature space, to represent the multivariate features. The p-value for covariance homogeneity test was≈0. The p-values for the pairwise Hotelling's T2 test of bivariate means of distribution of the first two principal components (to represent multivariate means of the distribution of features) are in the upper triangular part of Table 3. The hierarchical tree on the basis of the statistics is displayed in Figure 7 (B), but the rows and columns of the upper triangular part of Table 3 are also sorted according to the tree in Figure 7 (A) for consistency with the lower triangular part. The comparison using image features indicates that 44 out of 55 show statistically significant differences (of which 27 were comparisons involving HeLa, A-431 and U-2OS). However, when the estimated model parameters were compared (in the lower triangular part of Table 3 and Figure 7 (A)), 31 out of 55 comparisons showed statistical significance. Of these, 24 were comparisons involving HeLa, A-431 and U-2OS cells. Thus when these cells are subtracted (since they are clearly different from the rest of the cell lines), the number of presumed differences dropped from 31 to only 7. We believe that this is an indication of the utility of the method: the full set of features reflects a variety of differences among the cell lines in a range of possible (latent) parameters not necessarily directly relevant to microtubule distributions (such as cell size and shape and nuclear size and shape). The model parameter estimation is, on the other hand, able to ignore these, and focuses on microtubules. In that case, eight of the cell lines appear to be fairly similar. Consideration of all of Table 3, Figure 7 (A) and Figure 6 suggests that HeLa, A-431 and U-2OS are very different from those eight but A-431 and U-2OS are close to each other in the estimated model parameter space. The differences among the three groups can largely be accounted for by differences in total polymerized tubulin from Figure 6. Similarly, among the group of eight, we can observe that RT-4 appears to have fewer, longer microtubules, Hep-G2 appears to have lower total tubulin, and Hek-293 appears to have shorter microtubules.
Correlation between the estimated amount of polymerized tubulin and total tubulin fluorescence.
We compared the amount of polymerized tubulin, estimated as the product of the number and mean length of the microtubules, to the total intensity of each cell image. The plot of these two quantities for real cells from eleven cell lines is shown in Figure 8. The high correlations demonstrate the consistency between the estimated and real amount of polymerized tubulin and the effectiveness of our methods.
The correlation coefficient for each cell line is shown in the legend.
Discussion
We have developed an automated method to estimate 3D microtubule model parameters from 2D confocal immunofluorescence microscopy images in an indirect manner. The method is dependent on the 3D structure of the cell and the nucleus, and the centrosome location. We describe an automated approach in the method to generate an approximate 3D cell and nuclear morphology using only the 2D microtubule image and 2D nucleus image acquired at the center (half height) of the cell. We applied this method to generate distributions of microtubules in cells and utilized an indirect feature matching algorithm to estimate model parameters from 821 images of cells and 11 cell lines. Then the two quantitative parameters, number of microtubules and mean length of microtubules, were compared across cell lines. These two parameters are important because they demonstrate the fundamental physical characteristics of microtubules in cells.
To our knowledge, this study is the first attempt to quantify the number and mean of the length distribution of microtubules in intact cells across different cell lines. Methods such as electron microscopy can image intact cells, but have interference from other cell components [11]. More invasive methods of preparation such as extraction of the microtubule network can allow electron microscopy to generate traceable images, but are no longer representative of intact cells [12]. Fluorescence microscopy, on the other hand, can be used to obtain information about proteins at monomer-level resolution of localization without interference from other cell components in intact cells with high-throughput data.
One reason for studying microtubule distributions across cell lines is to begin to search for explanations of how expression of microtubule-associated proteins (MAPs) may account for any differences observed. The expression levels of many proteins vary across cell lines [13], and there are cell-specific proteins that regulate microtubules [14], [15]. In this paper, the cell lines chosen are from varying lineages, such as mesenchymal, epithelial and glial tumors, which may differ in their expression of MAPs. Our analyses show that some cell lines do have significant differences in the estimated parameters of the number and length distribution of microtubules. In future work, we hope to establish whether and how these differences results from variation in expression of specific MAPS.
There is evidence that the number and length of microtubules are correlated with the size of the cell [16], [17]. We therefore computed the area of the center slice (sum of pixels of the binary image) as the value reflecting the size of cytosolic space of the cell, for each of the cell lines. To quantify the correlation, we computed the correlation coefficient between the estimated total polymerized tubulin and the area of cytosolic space for each cell line. The plot of these two quantities for all cells is shown in Figure 9. The correlation coefficients varied from 0.46 to 0.81 which are intermediate to high. They add more confidence to the estimates of our automated approach and further confirm the existing hypothesis using alternative approaches.
The correlation coefficient for each cell line is shown in the legend.
The methods described here have potential applications in a range of experimental approaches. For example, microtubule interacting drugs (mitotic inhibitors) are commonly used for cancer chemotherapy, and our method could provide a quantitative measure of the effects of these drugs on different cancer cell types. It also could be used in high-content screening to distinguish different types of effects of compounds that disrupt microtubule dynamics.
Finally, we note that our estimation procedure is only appropriate for images and cell lines for which the majority of microtubules originate at the centrosome because we explicitly modeled all microtubules as starting from it. Therefore, the centrosomes may appear more focused in some synthetic images compared to the corresponding experimental ones for cell types that are less organized by centrosomes. Future work could include modifications to our modeling procedure so that it can be used with a more diverse set of experimental images and cell lines.
Materials and Methods
Data Acquisition
3D image data of HeLa cells.
We used 3D images of HeLa cells previously obtained by three color confocal immunofluorescence microscopy to visualize three cell components: the cell membrane, nucleus and microtubules [18]. The original pixel size was 0.05 microns, and the images were downsampled for computational efficiency to 0.2 microns.
2D images of eleven cell lines.
The data used here are confocal immunofluorescence microscopy images of fixed and interphase cells of eleven different cell lines: A-431, U-2OS, U-251MG, RT-4, PC-3, Hep-G2, HeLa, CaCo2, A-549, Hek-293 and MCF-7 from the HPA. They are human cell lines widely used in current research. The images were acquired as described previously [1], and the cell lines were obtained from ATCC-LGC Promochem (Boras, Sweden) except that the first two were obtained as described previously [1]. The images are analyzed as 8-bit TIFF images, with two files each obtained using a different emission wavelength of fluorescence from a single image field. These two channel files show the cellular probes/organelles used as references: (i) anti-tubulin antibody as internal control and marker of microtubules and (ii) DAPI for the nucleus. Each of the field images is of size 1728×1728 for the first three cell lines and 2048×2048 for the rest of eight, and the pixel size is 0.08 microns in the sample plane. The field images were then also downsampled for computational efficiency to 0.2 microns.
Computational Methods
Cell segmentation for cell size calculation and 3D morphology generation.
The field images were segmented into single cell regions using a seeded watershed method on the tubulin channel with the nuclei in the nuclear channel as seeds. The 2D cell and nuclear boundaries were found by thresholding the single cell regions and the nuclei respectively. These were used for cell size calculation and for 3D morphology generation (see below).
Point Spread Function (PSF) estimation.
The confocal PSF was generated computationally based on a theoretical model using the SVI PSF calculator for the Zeiss LSM 510 confocal microscope for the first three cell lines and the Leica SP5 for the other eight cell lines (http://www.svi.nl/NyquistCalculator). The pinhole size was set to 1 Airy Unit for the Zeiss and 285.16 nm for the Leica. The numerical aperture was 1.4 and the emission-excitation data used to generate the PSF was for the Alexa555 dye (http://probes.invitrogen.com/handbook/boxes/0442.html). The PSF is used to convolve on the generated raw image of distribution of microtubules to account for the digital blurring from microscopy imaging.
Centrosome location detection.
The 3D coordinate of the centrosome was estimated by breaking the problem into two parts. First, the XY-coordinate was estimated and then the Z-coordinate. The XY-coordinate was chosen as the pixel with the maximum intensity value in the vicinity of the nucleus after smoothing with an averaging filter of size 25 pixels on the tubulin channel image (as for cell image). For the Z-coordinate, we used linear regression to estimate the location as a function of the following predictor variables: (i) Maximum intensity of the microtubule image, (ii) Mean intensity of the microtubule image, and (iii) pixel intensity of the XY coordinate in the microtubule image. The coefficients of the linear regression were estimated from the 3D HeLa images where the 3D centrosome as described previously [8]. The estimated centrosome is then used to act as an organizer for microtubules and all generated microtubules start from it.
Estimation of single microtubule intensity.
The single microtubule intensity for each cell line was estimated using the method described previously [9]. It is then used to scale the intensity of synthetic image up to that of the real image.
3D cell and nuclear morphology generation.
In order to estimate the cell shape, we firstly required the following two estimates: (1) the cell shape at the bottom, where the cell membrane interacts with a substrate (e.g. petri-dish), and (2) cell shape decay from the bottom of the cell to the top.
For estimating the bottom shape of the cell, we used the microtubule channel image acquired at the center of the cell, i.e. z = Z/2, where Z is the height of the cell in pixel dimensions. This image contains information about the cell boundary at the bottom-most region because the out-of-focus light from the bottom slice is visible in the center slice (as microtubules being of relatively lower intensity). Hence, the boundary of the bottom slice (bottom shape) was found by thresholding for above zero intensity pixels. (see Figure 3 (A) for an example). Next, we represented the cell shape decay by estimating cell shape pixel area as a function of height of the cell, i.e. A(z). This function was estimated from the average area profile of the 2D slices in the 3D HeLa stack (data not shown) to be A(z) = 2−z*Area, where Area is the pixel area of the bottom slice, and z is the distance from the bottom. Since the cell tapers from the bottom shape to the top (because of the presence of a nucleus), we modeled the 3D cell shape by interpolating from the bottom shape of the cell to a smaller ellipse inside the cell whose major axis was aligned with that of the cell. This interpolation was done using distance transform based shape interpolation [19]. Given the height of the cell and the z-sampling step-size (0.2 microns, 1 pixel volume per stack), we discretized this model at varying z by choosing interpolated shapes that have areas that match the estimated area profile A(z) from the 3D HeLa stack. Figure 3 (C) shows an example of generated 3D cell shape containing 8 stacks (height of 1.6 microns). The 3D nuclear morphology was generated based on the same procedure above using the nucleus channel image (Figure 3 (D)). Then microtubules are generated conditioned on the approximate 3D cell and nuclear shape.
Growth model of microtubule patterns.
The growth model of microtubule patterns (Figure 1) is similar to the one described previously [8], with three modifications: (i) the Erlang distribution was used for microtubule lengths since, unlike the Gaussian distribution, it has only one free parameter; (ii) if the microtubule is required to make a turn in 3D space such that the 3D angle is greater than 63.9 degrees with cosine value of 0.44 (this value is chosen manually to account for appearance of real microtubules as well as the generability of the model), the growth procedure for it is terminated; and (iii) if within a consecutive 30 steps (about 6 microns) of growth of a microtubule, there are more than 3 pairwise vector angles that are greater than 120 degrees, the growth procedure for it is terminated. In order to ensure that the input parameters are exactly the same as the output parameters, we use the following algorithm to generate the images.
- Input parameters: number of microtubules (n), mean of the length distribution (mu), collinearity (α);
- Sample n lengths from Erlang distribution;
- Sort lengths from longest to shortest;
- Iterate until all lengths are generated, starting with the longest microtubule:
for i = 1 to n do
if storage has microtubule of desired length generated then
use the generated microtubule length;
remove chosen microtubule from storage;
continue, to the next microtubule.
end if
loop
Generate a microtubule using the method in Figure 1.
if the desired microtubule length cannot be generated then
add to storage and re-generate the microtubule.
if repeating 100 times still does not generate a microtubule of desired length then
return declare “input parameters cannot be generated”.
end if
end if
end loop
end for
Finally the generated image was convolved with the estimated PSF and was then multiplied with the corresponding estimated single microtubule intensity to make the intensity comparable to real images.
Library generation.
As described previously [8], a library of synthetic images was generated for each cell geometry (cell shape and nucleus shape) and contained all combinations of the parameter values below (resulting in a total of 810 synthetic images). The values were chosen by experience to account for the appearance of real microtubules as well as the generability and computational efficiency of the model):
- Number of microtubules = 5, 50, 100, 150, 200, 250, 300, 350, 400, 450;
- Mean of length distribution = 5, 10, 15, 20, 25, 30, 35, 40, 45 microns;
- Collinearity (cosα) = 0.97000, 0.98466, 0.99610;
- Cell Height = 1.2, 1.4, 1.6 microns.
Features and matching.
For each 2D real cell image and all the central 2D slices from its 3D simulated images in the library, 2D versions of the features that were used previously [8] were calculated. Detailed information about the implementations of the 2D version of the features have been presented [20]. In addition, we appended the feature set with edge features, which were some histogram features calculated on the gradient magnitude and gradient's direction after convolving each 2D image with Prewitt operator. Following the feature computation, we calculated the normalized Euclidean distances between the feature vector of the real image and those of its simulated images for matching. The set of parameters that was used to generate the simulated image with the minimum distance was used as estimates of the parameters of distribution of microtubules in that real image [8].
Acknowledgments
We thank other members of the Human Protein Atlas project team and the Murphy and Rohde groups for helpful discussions.
Author Contributions
Conceived and designed the experiments: JL AS EL GKR RFM. Performed the experiments: JL AS MW. Analyzed the data: JL AS EL GKR RFM. Wrote the paper: JL AS EL GKR RFM.
References
- 1. Barbe L, Lundberg E, Oksvold P, Stenius A, Lewin E, et al. (2008) Toward a confocal subcellular atlas of the human proteome. Mol Cell Proteomics 7: 499–508.
- 2. Reaven E (1982) Stereological analysis of microtubules in cells with special reference to their possible role in secretion. Methods Cell Biol 25: 273–283.
- 3. Shelden E, Wadsworth P (1993) Observation and quantification of individual microtubule behavior in vivo: microtubule dynamics are cell-type specific. J Cell Biol 120: 935–945.
- 4. Shi J, Orth J, Mitchison T (2008) Cell type variation in responses to antimitotic drugs that target microtubules and kinesin-5. Cancer Res 68: 3269–3276.
- 5. Wadsworth P, McGrail M (1990) Interphase microtubule dynamics are cell type specific. J Cell Sci 95: 23–32.
- 6. Yvon A, Wadsworth P, Jordan M (1999) Taxol suppresses dynamics of individual microtubules in living human tumor cells. Mol Biol Cell 10: 947–959.
- 7. Wolf K, Spanel-Borowski K (1995) Acetylation of alpha-tubilin in different bovine cell types: implications for microtubule dynamics in interphase and mitosis. Cell Biol Int 19: 43–52.
- 8. Shariff A, Murphy RF, Rohde GK (2010) A generative model of microtubule distributions, and indirect estimation of its parameters fromfluorescencemicroscopy images. Cytometry A 77: 457–66.
- 9. Shariff A, Murphy RF, Rohde GK (2011) Automated estimation of microtubule model parameters from 3-d live cell microscopy images. Proceedings of the 2011 IEEE International Symposium on Biomedical Imaging (ISBI 2011) 1330–1333.
- 10. Shaffer JP (1995) Multiple hypothesis testing. Annual Review of Psychology 46: 561–584.
- 11. Osborn M, Webster R, Weber K (1978) Individual microtubules viewed by immunofluorescence and electron microscopy in the same ptk2 cell. J Cell Biol 77: 27–34.
- 12. Letourneau P (1982) Analysis of microtubule number and length in cytoskeletons of cultured chick sensory neurons. J Neuro Sci 2: 806–814.
- 13. Duerr A, Pallas D, Solomon F (1981) Molecular analysis of cytoplasmic microtubules in situ: identification of both widespread and specific proteins. Cell 24: 203–211.
- 14. Shestakova E, Vandekerckhove J, DeMey J (1998) Epithelial and fibroblastoid cells contain numerous cell-type specific putative microtubule-regulating proteins, among which are ezrin and fodrin. Eur J Cell Biol 75: 309–320.
- 15. Slep KC (2010) Structural and mechanistic insights into microtubule end-binding proteins. Current Opinion in Cell Biology 22(1): 88–95.
- 16. Brinkley B, Cox S, Pepper D, Wible L, Brenner S, et al. (1981) Tubulin assembly sites and the organization of cytoplasmic microtubules in cultured mammalian cells. J Cell Biol 90: 554–562.
- 17. Goniakowska-Witalinska L, Witalinski W (1976) Evidence for a correlation between the number of marginal band microtubules and the size of vertebrate erthrocytes. J Cell Sci 22: 397–401.
- 18. Boland M, Murphy RF (2001) A neural network classifier capable of recognizing the patterns of all major subcellular structures in fluorescence microscope images of HeLa cells. Bioinformatics 17: 1213–1223.
- 19. Luo B, Hancok E (1997) Slice interpolation using the distance transform and morphing. Proceedings of the 13th International Conference on Digital Signal Processing Proceedings (DSP 97) 1083–1086.
- 20. Velliste M, Murphy RF (2002) Automated determination of protein subcellular locations from 3d fluorescence microscope images. Proceedings of the 2002 IEEE International Symposium on Biomedical Imaging (ISBI 2002) 867–870.