Abstract
In-line chlorination automatically treats drinking water in piped water systems, substantially reducing morbidity and mortality while averting the burden of water treatment on individuals. Approximately 2.3 billion people globally use fecally contaminated drinking water infrastructure that is potentially compatible with in-line chlorination. In India, the Ministry of Jal Shakti’s Jal Jeevan Mission has increased access to piped drinking water among rural households, but water is often supplied intermittently without treatment. The aims of this study were to 1) test installation and operations for two in-line chlorination devices (CTI-8 and PurAll 100), 2) evaluate acceptability and adoption of chlorinated water, and 3) assess reductions in drinking water fecal contamination, including with antibiotic resistant bacteria. We conducted a randomized controlled implementation trial of in-line chlorination in 20 villages in Rayagada district, Odisha, India over one year. Data collection included a baseline and post-intervention census (N = 914) and household surveys over six timepoints (N = 1,041) to assess water quality. In the treatment group, we detected chlorine in 51% of tap water samples; this prevalence rose to 78% after increasing the target dose. Despite taste complaints in treatment communities, participants continued using piped water as their primary drinking water source. Individuals in treatment villages spent less time manually treating their drinking water, a responsibility borne by women in 92% of households. Treatment reduced E. coli prevalence by 70% in tap water (95% CI: 54%, 80%) and by 47% in stored water (95% CI: 32%, 59%). Treatment also reduced the presence of antibiotic resistant E. coli by 67% in stored water (95% CI: 11%, 88%). In-line chlorination can improve water quality, lower the time burden of water treatment, and increase user adoption of chlorinated drinking water, but achieving this requires dedicated implementation and monitoring.
Citation: Lowe J, Prathap V, Kamei A, Giri S, Sahoo KC, Kremer M, et al. (2026) In-line chlorination for drinking water in rural Odisha, India: A randomized controlled implementation trial. PLOS Water 5(4): e0000440. https://doi.org/10.1371/journal.pwat.0000440
Editor: D. Daniel, Gadjah Mada University Faculty of Medicine, Public Health, and Nursing: Universitas Gadjah Mada Fakultas Kedokteran Kesehatan Masyarakat dan Keperawatan, INDONESIA
Received: August 26, 2025; Accepted: March 5, 2026; Published: April 29, 2026
Copyright: © 2026 Lowe et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All data and scripts are available on Open Science Framework https://osf.io/mx7z2/, DOI 10.17605/OSF.IO/MX7Z2.
Funding: Givewell provided funding for this research to MK, EMM, and AJP under a grant titled: “RCT of Water Quality Interventions: Phase 1.” This research is also funded in part by a pilot grant to JL at UC Berkeley by The Weiss Fund for Research in Development Economics at the University of Chicago. AJP is a Biohub, San Francisco Investigator. JL is a recipient of the Digital Transformation of Development Fellowship supported by the National Science Foundation under Grant No. DGE- 2125913. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. We declare no competing interests as part of this research.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Sustainable Development Goal (SDG) 6.1 aims to provide universal access to safely managed drinking water by 2030, which is defined as greater than 99% of the population having access to an improved water source that is accessible on premises, available when needed, and free from fecal and priority chemical contamination [1]. However, current rates of global progress need to be quadrupled to meet SDG 6.1 by 2030 [2]. New evidence suggests that 1 in 3 people in low- and middle-income countries (LMICs) lack access to safely managed drinking water [2]. Fecal contamination is the limiting factor in achieving access to safely managed drinking water for almost half of the population living in LMICs [2], emphasizing the importance of water treatment in achieving universal access to safe drinking water.
Drinking water treatment is a cost-effective strategy to reduce diarrheal disease and child mortality globally. A systematic review found that water treatment interventions can reduce diarrhea in children under five by about 24% as compared to settings without water treatment [3]. A recent meta-analysis of 18 water treatment randomized controlled trials (RCTs) also suggests a 23% reduction in the odds of all-cause mortality in children under five from water treatment, primarily driven by the use of chlorination, and a cost per disability-adjusted life year (DALY) averted of about USD 28 to USD 72 depending on method [4]. The transmission of antibiotic resistance in the environment is also widely recognized as a threat to public health [5–8], yet no RCTs have evaluated the impact that improved water treatment infrastructure can have on reducing human exposure to antibiotic resistance through drinking water [7,9].
Achieving high and sustained adoption rates is a key challenge for water treatment interventions. Point-of-use water treatment methods such as boiling or manual chlorination require sustained behavior change, the burden of which often falls on women and often leads to lower adoption. A systematic review finds average adoption rates of 47% for point-of-use chlorination, falling to 11% for studies in which participants were visited less than once a month by study staff [10]. Some studies have found reductions in treatment after interventions or regular visits ended [11]. Perhaps due to low adoption, some studies of point-of-use water treatment find null effects on child health outcomes [12–15]. Other evidence suggests that consumers are often willing to pay for convenient access to water but have low willingness to pay for water treatment [16], making it challenging to sustain programs through user fees for water treatment.
In-line chlorination is a promising low-cost water treatment solution that can address implementation barriers to scale [17]. Chlorination has been historically used to disinfect drinking water supplies and has reduced enteric disease burden and mortality globally [18]. In-line chlorination is a water treatment method employing devices that automatically dose chlorine without requiring electricity or daily operation installed at community- or institution-level water points such as water storage tanks, pipelines, or at points-of-collection [19]. In-line chlorination can also reduce cost and time burdens on individuals as compared to point-of-use water treatment methods [11]. A variety of in-line chlorination technologies are now available in the market, including open source products such as chlorine tablet erosion dosers that can be constructed from locally available plumbing materials [17]. A previous RCT in Dhaka, Bangladesh, observed a 23% reduction in child diarrhea following an in-line chlorination intervention in community water systems, with a detectable free chlorine residual at household tap connections 83% of the time [20]. Approximately 2.3 billion individuals globally use drinking water infrastructure that is potentially compatible with in-line chlorination, presenting an opportunity to continue scaling up across multiple contexts [21]. However, before in-line chlorination can be implemented at such a large scale, effective operational procedures need to be evaluated to support implementers across diverse infrastructure and institutional contexts.
In India, the Ministry of Jal Shakti’s Jal Jeevan Mission aimed to supply safe drinking water through household tap connections to all rural Indian households by 2024 and was recently extended to 2028 [22,23]. As of December 2025, approximately 82% of households in India had access to a tap connection providing at least 55 liters per capita per day [24]. The Jal Jeevan Mission supported state governments in the construction of new drinking water supply infrastructure and retrofitting old water supply schemes to achieve the large increase in household piped water access [25]. Through the Jal Jeevan Mission, drinking water is supplied to rural villages either through single- or multi-village distribution networks in which water is pumped from boreholes to elevated storage tanks and gravity-fed through pipes to household tap connections [25]. However, water is only supplied intermittently for a few hours each day, which can introduce microbiological contamination [26,27]. Intermittent water supply is estimated to cause about 109,000 diarrhea-related DALYs per year globally [28]. In-line chlorination can provide decentralized treatment in intermittent water supply systems where centralized water treatment is ineffective due to recontamination of water during pipeline de-pressurization. In-line chlorination is a potentially compatible and scalable strategy for drinking water infrastructure delivered through the Jal Jeevan Mission. However, in single-village schemes (which serve approximately 60% of rural India), there is typically no system for automatic chlorination, thus requiring daily manual effort by village pump operators to conduct water treatment. The effectiveness of in-line chlorination in providing sustained water treatment in this context is relatively unknown.
We conducted a randomized controlled implementation trial of in-line chlorination in rural Indian villages served by the Jal Jeevan Mission. The aim of this study was to field test installation and operation procedures to inform local guidelines for implementing in-line chlorination and understand if chlorinated water would be acceptable to users. In addition, we evaluated how effectively in-line chlorination could chlorinate drinking water and its impact on reducing levels of fecal contamination and antibiotic resistant fecal bacteria. This study was also conducted to assess the feasibility of a larger study powered to detect the effects of in-line chlorination on health outcomes.
Materials and methods
Ethics statement
The study was conducted with permission from the Department of Panchayati Raj and Drinking Water, Government of Odisha and in consultation with Jal Jeevan Mission. In August 2023, the Government of Odisha issued a permission letter to facilitate the RCT in villages in Rayagada district. Research ethics approvals were received from the Institutional Ethics Committee of ICMR-Regional Medical Research Centres, Bhubaneswar. This study was also approved by the Directorate of Health Services, Government of Odisha. Institutional review board approval for human subjects research was received from the University of Chicago (IRB #23–0842) and the Institute for Financial Management and Research in India (IRB #0924–66). Informed consent was provided by participants prior to enrollment. Study enumerators provided and read aloud the informed consent document for participants in their preferred language (Odia, Telugu, Hindi or English). Verbal consent was recorded by the enumerator using an electronic survey. The use of verbal consent was approved by both IRBs. Participants received a small gift (valued less than ₹300 INR ($3.27 USD)) as compensation for participating in surveys.
Study design
We conducted a cluster-randomized controlled implementation trial in 20 villages in rural Odisha, India; 10 villages were randomly assigned to receive an installation of in-line chlorine dosers and 10 to a control group where no intervention took place. Villages were enrolled into the study following an infrastructure assessment by a civil engineer to determine if the piped water infrastructure was compatible with in-line chlorination.
Villages were considered eligible for the study if they met the following criteria: 1) the piped water infrastructure supplied water to a single village through a central tank and was compatible with a tablet-based chlorine doser at the inlet or outlet of the tank, 2) the turbidity of drinking water sources was less than 5 nephelometric turbidity units (NTUs), 3) the water distribution infrastructure did not have any major issues preventing water supply or in-line chlorination installation (e.g., major leaks at valves, dysfunctional borewell pump, major disruptions in electricity supply lasting multiple days, etc.), 4) water was supplied at least once daily for any amount of time through household tap connections, and 5) there were no plans for the village piped water supply to be converted to a larger distribution scheme connected to a centralized drinking water treatment plant in the following year. High turbidity influenced water source eligibility given its impact on reducing disinfection effectiveness and association with elevated levels of organic and inorganic matter, which could increase formation of disinfection byproducts [29,30].
Based on administrative information shared by the Department of Panchayati Raj and Drinking Water, we selected Rayagada district of Odisha given the relatively high prevalence of single-village water distribution schemes compared to other districts. In consultation with the department, we identified villages reporting near complete coverage of tap connections in households and served by a single-village water distribution scheme. Among these, a civil engineer visited villages to assess the compatibility of the piped water supply infrastructure with in-line chlorination (see above criteria). The civil engineer visited 33 villages in total and identified 22 eligible villages in Rayagada for the study in August 2023. Twenty villages were enrolled in the study, while an additional two villages were only enrolled at baseline as backup villages in the event a village needed to be replaced for major infrastructure failures (e.g., pipeline breaks). The sample size was limited by the study budget. After baseline data collection but before intervention rollout, one of the treatment villages had to be dropped and replaced with a backup village from another block due to a breakage in the supply pipeline resulting in people primarily using alternative water sources besides their household tap connections.
Before the in-line chlorination implementation, we conducted a baseline census where all households were visited to identify households with mothers and children under five (N = 914) in 20 villages. A subset of households (N = 200) was assessed for water use practices and water quality, including measurements for free and total chlorine and Escherichia coli (E. coli). Villages were then randomly assigned to control or treatment groups, where 10 out of 20 villages were randomly assigned to receive the in-line chlorination intervention. The randomization was stratified by block (a sub-district administrative unit) and if the village was the Gram Panchayat headquarters. Among the treatment group, we implemented two in-line chlorination technologies that automatically dose chlorine into piped water supply without the need for electricity via chlorine tablet erosion: the PurAll 100 [31] and an open-source technology called CTI-8 [32]. We followed up in the 20 villages over one year through six data collection rounds to assess changes in water use practices and water quality (Fig 1).
“Rainy, E. coli, Tap, Survey, Village, and Random” icons were sourced from The Noun Project.
Intervention delivery
We used two chlorine tablet-based in-line chlorination technologies in the intervention: the commercially available PurAll 100 [31] and open-source CTI-8 [32] (S1 Fig). Each tablet doser operated by redirecting a proportion of flow through a cartridge containing solid trichloroisocyanuric acid (TCCA) tablets, which would passively dissolve and dose chlorine into the drinking water pipeline via a bypass line. We used the PurAll 100 based on its commercial availability in India and the open-source CTI-8 because it could be assembled on-site using locally available materials. Both technologies were also compatible with existing drinking water infrastructure. Drinking water in the study villages was supplied intermittently by pumping groundwater into an elevated storage tank (40,000–100,000 L capacity) via an electric borehole pump; water was then released by gravity flow through the distribution network to individual household tap connections once or twice per day for one to two hours on average by the pump operator. Villages ranged in size between 67 and 380 households, and each household had their own tap connection. We installed each tablet doser on the inlet pipeline leading into the tank which allowed chlorinated water to have contact time for disinfection between supply cycles. The material costs for the parts to build the CTI-8 device were approximately ₹4000 INR ($47 USD), and the PurAll 100 device cost approximately ₹25500 INR ($307 USD). A PurAll 100 chlorine tablet cartridge used 10 200 gram TCCA tablets and cost ~ ₹4700 INR ($57 USD) and was advertised to treat 2.5 million liters of water at 1 mg/L concentration. The equal-capacity CTI-8 chlorine tablet refill cartridge cost ~ ₹432 INR ($5 USD) with tablets purchased from an alternative vendor (Acuro Organics Limited, New Delhi, India). In our study, we observed the cost per 1,000 liters of treated water with a free chlorine residual of 0.2-0.6 mg/L was about $0.04 USD per 1,000 liters for the PurAll chlorine tablets and $0.004 USD per 1,000 liters for the CTI-8 with chlorine tablets from the alternative vendor (based on the average volume of water supplied per day, 64,000 liters, and the average number of days between refills, 21.4 days).
Gram Vikas, a non-governmental organization operating throughout Odisha, co-designed the intervention and led the implementation. Prior to installation of the in-line chlorination technologies, Gram Vikas conducted two community sensitization meetings. The first meeting discussed the purpose of in-line chlorination with the village sarpanch, a locally elected leader to the Gram Panchayat, and borehole pump operator; this was followed by a village meeting with general community members to introduce in-line chlorination as a water treatment method and answer questions. Additional meetings were conducted on an as-needed basis by a social coordinator and resulted in approximately two to four more village meetings per community over the study period. Between December 2023 and January 2024, PurAll 100 tablet dosers were installed in four villages, and CTI-8 tablet dosers were installed in six villages. Tablet dosers are often designed to operate under low pressure or unpressurized systems, but we successfully adapted these to operate under pressurized conditions at ground level before water was piped into elevated storage tanks. In 3 villages, tanks had two inlet lines (e.g., two borewells pumping into the tank) and we installed one device on each tank inlet line. In one village, an inlet installation was not feasible because the entire inlet line was routed under a concrete platform, but we were able to achieve effective dosing by installing two tablet dosers in series on the outlet line. A plumber and engineer visited each site twice: once to gather measurements for required materials and a second time to complete the installation which took between one to four hours.
We targeted a free chlorine concentration range of 0.2-0.6 mg/L at the tap connections throughout the piped system. We selected this target free chlorine concentration based on a previous study which identified a median taste detection threshold of 0.7 mg/L from taste acceptability tests in Bangladesh [33]. We also targeted this range because it aligned with the World Health Organization (WHO)’s recommendation for a minimum free chlorine residual in drinking water (0.2 mg/L) and when there is a known risk of fecal contamination (0.5 mg/L) [34]. Following installation of the tablet dosers, Gram Vikas visited each village daily during the water supply time to iteratively adjust the dose control valves until the chlorine concentration was observed within the target range. Multiple days of testing and dose adjustment were necessary for controlling the chlorine concentration because water was supplied intermittently, which meant a dose adjustment on one day could only be assessed the following day when water was being supplied. Gram Vikas monitored the performance of the tablet dosers each week for the duration of the study by testing for free and total chlorine concentrations at the nearest and farthest tap connections per village and providing refills and maintenance as needed. On average, Gram Vikas provided refills to the chlorinators every 21.4 days (SD = 12.6 days) depending on the village. Gram Vikas followed a protocol to proactively refill tablets before they were completely depleted; they provided refills when at least three partially dissolved tablets remained to prevent interruptions in chlorination.
After observing frequent no-dosing events, we increased the target chlorine concentration range to 0.4-0.6 mg/L in August 2024. By increasing the target chlorine concentration, we expected to observe improved disinfection and a greater proportion of tap connections with a detectable concentration of chlorine (> 0.1 mg/L). We also expected a decrease in no-dosing events caused by variability in the tablet dosers as chlorine tablets dissolved.
Data collection procedures
Alongside our data collection partner, the Abdul Latif Jameel Poverty Action Lab (J-PAL) South Asia, we conducted baseline data collection in all study villages in October 2023 to understand usage of tap connections and water quality prior to implementing the in-line chlorination intervention. We conducted a census of all households with pregnant women or children under the age of five (N = 914) and asked questions of the female head of household related to demographics, water, sanitation, and hygiene (WASH) access, and health. We followed up with a subset of 200 households – who reported drinking water from their household tap connection – with a longer survey to characterize water treatment practices, perceptions of chlorination, and test for free and total chlorine residual at their tap connection. In a randomly selected subset of 80 households (out of 200), we also collected drinking water samples from tap connections and stored water containers and characterized microbiological contamination by quantifying total coliform and E. coli concentrations.
All surveys were conducted on electronic tablets using SurveyCTO, a computer-assisted personal interviewing software (Dobility, Cambridge, MA, USA). Drinking water samples were collected from household tap connections and water storage containers and tested for microbiological contamination using a defined-substrate assay, IDEXX, to enumerate the most probable number (MPN) of total coliform and E. coli per 100 mL of water (IDEXX Laboratories, Inc., Westbrook, ME, USA). Water samples were collected using sterile gloves and sample collection bags containing sodium thiosulfate (Whirl-pak, Madison, WI, USA) to deactivate residual chlorine, then transported in coolers and on ice to a field laboratory within six hours. Water samples were collected from tap connections after letting water flow from them at their highest flow rate for 30 seconds, after the water supply in the village had been on for at least five minutes. For stored water samples, respondents were asked to provide water from their storage container they would drink from. Samples were processed using the IDEXX quanti-tray system and incubated for 18–24 hours at 35 °C. Two trained lab technicians counted wells that were positive for total coliform and E. coli and a supervisor separately checked their counts. We took quality control measures to assess contamination including testing lab blanks on a daily basis, field blanks on a weekly basis, and duplicate samples in 2% of all samples. Field and lab blanks involved processing and analyzing separate 100 mL samples of sterile water collected either in the laboratory or the field. No field (N = 27) or lab blank (N = 131) samples tested positive for E. coli. Free and total chlorine residual were tested using a N,N-diethyl-p-phenylenediamine (DPD) colorimetric method with HACH DR300 colorimeters (HACH, Loveland, CO, USA). We also tested for antibiotic resistant (ABR) E. coli in a random subset of samples from baseline and follow-up rounds using a modified validated IDEXX assay. The modified assay quantified phenotypic resistance of presumptive extended spectrum beta lactamase (ESBL)-producing E. coli by adding 80 µL of 5 mg/mL cefotaxime solution to each 100 mL sample [35]. This resistance mechanism confers resistance to several critically important antibiotics, including third generation cephalosporins [5].
After implementation of the in-line chlorination intervention between December 2023 and January 2024, we conducted follow-up data collection until October 2024. In all 20 villages, six follow-up surveys were conducted in February, March, April, August, September, and October 2024. The monsoon season began in July 2024, which resulted in increased precipitation during the August, September, and October 2024 rounds. During the February, March, and April follow-up rounds, 10 households were randomly selected in each village (N = 200) from the baseline census list and surveyed about their water treatment practices, perceptions of chlorination, and had their tap and stored water tested for free and total chlorine residual. In a random subset of four households per village, we also collected drinking water samples from tap connections and stored water containers and quantified the MPN per 100 mL for total coliform and E. coli (N = 80). In the August, September, and October follow-up rounds, we reduced the number of surveys to 4 randomly-selected households in each village due to budget constraints (N = 80). Testing for presumptive ESBL-producing E. coli was conducted during the October 2023, April 2024, and October 2024 rounds. An additional census of households with pregnant women and children under five was conducted in May 2024 to assess usage of the tap connections and adoption of chlorinated drinking water after being exposed to the intervention for 4 months (N = 886).
Independently from Gram Vikas, J-PAL South Asia visited each village with an installed chlorine doser weekly, during which they tested drinking water from tap connections and stored water containers for free and total chlorine residual to assess if the concentration was within the target range. In the event a measured chlorine concentration was outside the target range, we informed Gram Vikas, who would take action to meet the target range either by adjusting the control settings or providing a refill. Tests were conducted at the nearest and farthest households in each village to assess if there was any significant decay in the chlorine concentration over the length of the distribution pipeline. We also tested for free chlorine at five minute intervals over the complete supply time at the nearest and farthest tap connections from the storage tank to assess any variation in dosing while water was being supplied.
Outcomes and statistical analyses
Our primary outcomes included free and total chlorine residual and E. coli contamination in tap and stored water samples, reported usage of the piped water system, and water treatment practices. We created binary presence/absence variables for free and total chlorine residual with a positive detection threshold of 0.1 mg/L to account for the detection limit of the colorimeters and their error range. We created binary variables representing the presence or absence of total coliform and E. coli in tap and stored drinking water samples. We log10-transformed MPN estimates for E. coli and imputed non-detects with a value representing half the detection limit (0.5 MPN per 100 mL) to allow for log-transformation [36,37].
Prevalence ratios (PR) for all primary outcomes were estimated using Poisson regression. Counts of outcome observations were summed at the village-level and an offset covariate for the number of observations within each village was included in the model specification. Villages were followed up with over equal time periods. We also estimated average reductions in log10 MPN counts for total coliform and E. coli using linear regression applied to individual-level data with robust standard errors. All models included covariates for baseline outcome measurements for each village, to control for any imbalance between treatment and control groups at baseline. Analyses were performed using R version 4.3.1 (CRAN).
In March 2024, one treatment village requested their in-line chlorination device to be uninstalled following concerns about taste and smell of the drinking water. However, this village was still included in the analysis, thus estimating the intention-to-treat effect of our in-line chlorination intervention.
Results
Baseline demographics, water use, and water quality
The baseline census identified 3,848 households in the 20 villages during October 2023. Among these, 914 households had children under five or pregnant women and participated in the census survey (N = 491 in control villages; N = 423 in treatment villages) (Table 1).
Most respondents reported using their household tap connection as their primary source of drinking water (77% of households in the control group, 81% of households in the treatment group). Respondents also reported using a secondary drinking water source to supplement their drinking water needs in 25% of control and 33% of treatment households. Treating drinking water before consumption was reported by 44% of control and 48% of treatment households. The reported water treatment methods used included boiling, filtering water through a coarse cloth, or allowing water to settle for a period of time before consumption. No respondents reported chlorinating their drinking water before consumption. Women were primarily responsible for water collection in 79.5% of households. In 19.5% of the households, both adult women and men were reported responsible for water collection, and in 1% men were responsible. In households that treat their drinking water, 92% reported that only women were responsible for treating water, 1% reported men were responsible for treating water, and 7% reported that both women and men were responsible. Respondents reported being satisfied with the taste of their tap water in 97% of control and 91% of treatment households.
We detected E. coli (>= 1 MPN/100 mL sample) in 38% of tap samples from treatment households and 70% of tap samples from control households (Fig 2). However, this baseline difference was not statistically significant (p-value = 0.14). No other differences in baseline measurements between control and treatment groups were statistically significant after controlling for block stratification. We detected E. coli in 60% and 73% of stored drinking water samples in the treatment and control households at baseline, respectively (Fig 3). Total coliform bacteria were detected in all samples from taps and stored water in both control and treatment households. At baseline, antibiotic resistant E. coli was detected in stored drinking water samples from 22% of control households and 15% of treatment households. We were unable to detect antibiotic resistant E. coli in any tap samples from control households at baseline, but detected it in 4% of tap samples from treatment villages.
Free chlorine concentrations were tested on a weekly basis at two taps in each village with a chlorine doser installed. The proportion of tap connections with detectable free chlorine concentrations (> 0.1 mg/L) were averaged across 9 treatment villages on a bi-weekly basis. The averages reported are unconditional means and do not control for randomization stratification variables. One treatment village requested their chlorine doser to be uninstalled in March 2024, and we stopped weekly monitoring for free chlorine residual, but continued testing for E. coli contamination. The proportion of taps with a presence of E. coli was averaged across all 20 communities for each data collection round, stratified by treatment assignment. Error bars on figures represent 95% confidence intervals.
The proportion of samples with a presence of E. coli was averaged across all 20 communities for stored water (Panel A) and tap water (Panel B) for baseline and all 6 data collection rounds and stratified by treatment assignment. The averages reported above are unconditional means. Antibiotic resistant E. coli contamination was also assessed during baseline and the April 2024 and October 2024 data collection rounds for stored water (Panel C) and tap water (Panel D). Error bars on both figures represent 95% confidence intervals.
Performance of the in-line chlorine dosers
Over the study period, the average proportion of tap connections with a detectable presence of free chlorine (> 0.1 mg/L) was 51% and ranged between 14% to 88% during the weekly monitoring rounds in communities with an installed chlorine doser. The average concentrations of free and total chlorine at tap connections were 0.26 mg/L (SD = 0.33 mg/L) and 0.28 mg/L (SD = 0.35 mg/L), respectively (S2 Table). For stored water samples, the average free and total chlorine concentrations were 0.10 mg/L (SD = 0.20 mg/L) and 0.12 mg/L (SD = 0.21 mg/L) (S2 Table). Free chlorine was detected in 19% and total chlorine in 26% of stored water samples during weekly monitoring. The mean difference between free and total chlorine among paired samples was 0.06 mg/L. The overall average free chlorine concentration at tap connections was 0.27 mg/L (SD = 0.32 mg/L) for the CTI-8 and 0.23 mg/L (SD = 0.36 mg/L) for the PurAll 100. No detectable chlorine in tap water would often occur when chlorine tablet refills were not provided in time or due to noncompliance by village pump/valve operators, who would turn off the chlorine dosers in response to taste and odor complaints by community members. At other times, as chlorine tablets dissolved and their surface area and mass decreased, we hypothesized that the chlorine dosing rate decreased, as observed in prior bench-scale testing [38], and the average chlorine dose at tap connections would often drop below detectable concentrations. Following an increase in the target dose range to 0.4 to 0.6 mg/L in the 9 treatment villages still receiving chlorinated water in August 2024, the average proportion of taps with a detectable concentration of free chlorine was 78% over 6 weeks. The average free chlorine concentration was 0.46 mg/L (SD = 0.41 mg/L) during this period (Fig 2).
Paired chlorine concentration measurements from the nearest and farthest tap connections differed by an average 0.11 mg/L (SD = 0.11 mg/L), indicating there was no major decay in chlorine concentration along the distribution network in any treatment village. The chlorine concentration at each tap connection was consistent across the full supply cycle in most treatment villages (S2 Fig). In one village, a second borehole well was repaired in July 2024 and began to supply unchlorinated water to the central tank through an additional pipeline. The pump operator in the village would only operate this second borehole when water was being supplied to the village to extend the supply time, which meant the chlorinated water in the tank would become diluted with unchlorinated water from the second borehole. We observed a maximum decrease of 0.51 mg/L in the chlorine concentration at the taps in this village during the supply time.
Effect of in-line chlorination on microbial water quality
During household follow up surveys in each village, we detected free chlorine (> 0.1 mg/L) in 51% of tap and 25% of stored water samples from the treatment group across 6 follow-up data collection rounds (S1 Table). However, following an increase in the target chlorine dose to be 0.4 to 0.6 mg/L during the last data collection round, we observed an increase in the proportion of samples with free chlorine to 80% of tap samples and 45% of stored water samples. We detected free chlorine in 0.2% of tap and stored water samples in the control group, but these are presumed to be false positives since chlorination is not practiced. Over 6 follow-up rounds, 67% of tap samples from control households tested positive for E. coli as compared to 16% of tap samples from treatment households (Fig 3). Similarly, 83% of stored water samples from control and 44% of samples from treatment households tested positive for E. coli. We observed ABR E. coli in 26% of stored water samples in control households and 8% of stored water samples in treatment households. We detected ABR E. coli in 11% of control tap water samples, while it was absent from all treatment tap samples.
A small proportion of water samples with a free chlorine concentration greater than 0.2 mg/L still tested positive for E. coli (Fig 4) (3.8% of tap and 7.3% of stored water samples with greater than 0.2 mg/L). For samples with detectable concentrations of free chlorine, we also estimated reductions in the presence of E. coli as free chlorine concentrations increased. For every 0.1 mg/L increase in free chlorine concentration, we observed an 18% reduction in the presence of E. coli from tap connections (p-value = 0.052), but did not find a significant association in stored water samples (S3 and S4 Figs, S3 Table). The proportion of stored water samples with a detectable concentration of free chlorine increased as the free chlorine concentration at tap samples increased (S5 Fig).
The proportion of tap and stored water samples with a presence of E. coli was averaged across all 20 communities for all 6 data collection rounds and stratified by their free chlorine concentration.
After pooling microbial water quality data from all 6 data collection rounds, we estimate that treatment reduced the presence of E. coli in tap water by 70% as compared to the control group (PR: 0.30, 95% CI (0.20, 0.46); p-value < 0.001) (Fig 5). We also estimate that the presence of E. coli in stored drinking water was reduced by 47% in the treatment group as compared to the control group (PR: 0.53, (0.41, 0.68); p-value < 0.001). We observed an average reduction of 1.31 log10 MPN total coliform (𝛽 = -1.31, 95% CI (-1.78, -0.84); p-value < 0.001) and 0.55 log10 MPN E. coli in tap water (𝛽 = -0.55, 95% CI (-0.90, -0.20); p-value < 0.001) in treatment households as compared to control (Table 2).
Treatment effects on key water use outcomes were estimated after 4 months of exposure to the in-line chlorination intervention during a household census. Village-level prevalence ratios were estimated using Poisson regression with standard errors clustered at the village level. Models control for baseline measurements for each village.
We similarly observed a 0.74 log10 MPN total coliform (𝛽 = -0.74, 95% CI (-1.04, -0.36); p-value < 0.001) and 0.63 log10 MPN E. coli reduction in stored water (𝛽 = -0.63, 95% CI (-0.90, -0.36); p-value < 0.001) among treatment households compared to control. We also estimated a reduction in ABR E. coli in stored drinking water following treatment (PR: 0.33, (0.12, 0.89); p-value = 0.029). We did not detect any ABR E. coli in tap water samples from treatment villages, but we detected ABR E. coli in 11% of control samples and therefore did not estimate a prevalence ratio for this comparison.
Effect of in-line chlorination on water use and treatment
We did not observe any statistically significant differences between treatment and control households related to their use of household tap connections as the primary drinking water source (PR: 1.03, (0.87, 1.21); p-value = 0.747), use of a secondary drinking water source (PR: 0.94 (0.74, 1.18); p-value = 0.591), or consumption of tap water (PR: 1.06, (0.90, 1.24), p-value = 0.495). We saw a reduction in the proportion of participants who report treating their drinking water among the treatment group when compared to the control group (PR: 0.87, (0.74, 1.03); p-value = 0.109). We similarly observed a reduction in the proportion of participants spending more than 5 minutes treating their drinking water each day among the treatment group when compared to the control group (PR: 0.81, (0.67, 0.99); p-value = 0.036). Only 1 out of 475 participants (0.2%) in the control group mentioned an aversion to the taste or smell of water from their tap connection, as compared to 40 out of 405 participants (9.9%) in the treatment group.
Discussion
Effect of in-line chlorination on water quality
Our study demonstrated that in-line chlorination, with dedicated monitoring, can effectively reduce fecal contamination in piped drinking water in rural India, without causing users to switch from the piped system to alternative, non-chlorinated drinking water sources. This is the first randomized implementation trial of in-line chlorination in India to demonstrate that chlorine tablet-based chlorinators could be adapted to operate under pressurized flow in piped water systems. Although we detected chlorine in only approximately half (51%) of tap samples during the first 6 data collection rounds in treatment households, this proportion greatly increased to 80% of taps during the final data collection round following an increase in the target free chlorine residual dose to a minimum of 0.4 mg/L. Previous evaluations of in-line chlorination involving chlorine tablet-based dosers in gravity-fed systems have detected a free chlorine residual in 40%-100% of water samples [17,39–43]. It is difficult to isolate the reason for the variation across studies because flow conditions, chlorine demand from source water, distribution network lengths, target chlorine dosing ranges, and operational schemes vary both between and within studies. The results from this study and others highlight the importance of developing operational procedures to achieve the best performance of in-line chlorination, including the target chlorine concentration, management schemes, operator incentives, and refills frequency [41,42]. Future in-line chlorination interventions can improve performance by targeting a free chlorine residual in the middle of the acceptable range (e.g., 0.5 mg/L to achieve a range of 0.2 mg/L to 0.8 mg/L) to account for fluctuating chlorine dosing due to chlorine demand in source water and variable performance of different in-line chlorination technologies. The acceptable range can be determined based on a local context’s water quality guidelines, expected standard deviation in dose, and taste and odor preferences, but the WHO recommends a minimum chlorine dose of 0.2 mg/L in drinking water (0.5 mg/L when there is a known risk of fecal contamination) [34].
We observed reductions in antibiotic resistant E. coli in drinking water among households with chlorinated water as compared to households with untreated water. Under the growing threat of antibiotic resistance transmission through the environment, the WHO’s Global Tricycle Surveillance project has recommended the use of ESBL-producing E. coli as a global indicator in environmental surveillance of antibiotic resistance [5]. Drinking water has also been identified as an environmental reservoir of concern and recommendations have been made for the expansion of water treatment to limit antibiotic resistance transmission [7,9]. Our study expands upon these recommendations by using presumptive ESBL-producing E. coli as a process indicator for controlling antibiotic resistance through in-line chlorination. Stored drinking water from treatment households was 67% less likely to have a presence of ESBL-producing E. coli as compared to control households, and we were unable to detect any ESBL-producing E. coli in treatment household tap samples during follow-up data collection rounds (compared to 11% prevalence in control taps). Our study suggests in-line chlorination is an effective strategy for reducing human exposure to antibiotic resistant bacteria in drinking water. Future studies should consider the possible combined benefits of in-line chlorination in reducing diarrheal disease burden, mortality, and the burden of antibiotic resistant bacterial infections. Future studies could also consider adopting ESBL-producing E. coli as a water quality outcome to better understand how water treatment can reduce human exposure to antibiotic resistant bacteria.
In-line chlorination can reduce exposure to fecal contamination, but, at the same time, can potentially increase exposure to disinfection byproducts (DBPs). Disinfection byproducts (DBPs) can form after chlorine reacts with inorganic and organic matter and includes trihalomethanes (THMs), haloacetic acids (HAAs), and other known compounds of varying toxicity in humans [44,45]. A recent meta-analysis of 16 epidemiologic studies found that chronic exposure to elevated levels of THMs is associated with increased risk of colorectal and bladder cancer [46]. However, disinfection efficacy should not be compromised in favor of limiting DBP formation [34]. We did not measure DBPs here, but this research can be complemented by future studies aimed at characterizing DBP formation in low- and middle-income countries following chlorination. In India, Furst et al. tested treated surface water from water treatment plants in Rajasthan and found that unregulated DBPs, including haloacetamides (HAMs) and haloacetonitriles (HANs), contributed more to total toxicity metrics as compared to THMs, which were within regulatory limits [47]. These results are important in the context of in-line chlorination using sodium dichloroisocyanurate (NaDCC) or TCCA tablets, where recent evidence also suggests that chlorocyanurate tablets may limit formation of regulated DBPs, like THMs, but could increase formation of unregulated DBPs, like nitrogenous DBPs, as compared to typical hypochlorite solutions [48,49]. When in-line chlorination is introduced in drinking water infrastructure, several steps can be taken to reduce DBP formation without limiting disinfection efficacy: 1) Sources can be selected with lower concentrations of DBP precursors (natural organic matter, nitrogen, bromide, iodine, etc.) [50], 2) a pre-filter can be installed or improvements can be made to distribution infrastructure to prevent infiltration, especially in intermittent water supply schemes [50,51], and 3) precise dosing can be maintained to ensure effective disinfection while avoiding overdosing which can increase concentrations of DBPs [52–54]. As more people gain access to treated drinking water via in-line chlorination, future research should continue investigating DBP concentrations across diverse settings to improve understanding of potential exposure risks.
We also note that specific opportunistic pathogens (e.g., Legionella pneumophila and Pseudomonas aeruginosa) can persist in pipeline biofilms, and free chlorine is generally ineffective at inactivating pathogens in biofilms [55]. Other treatment strategies exist for biofilms, like chloramination [56], and further research is needed to assess how this could be implemented in the context of in-line chlorination.
Effect of in-line chlorination on water use and treatment
Participants in treatment communities were less likely to spend greater than 5 minutes per day treating drinking water compared to participants in control communities. Few studies have quantified the time spent treating water associated with drinking water treatment interventions and who the responsibility falls to in the household [10,11,57–59]. One factor limiting take-up of point-of-use water treatment programs may be the time it requires for users, often women, to treat water [11]. While other studies providing drinking water through continuous piped systems have estimated significant decreases in time spent collecting water [60,61], here we were able to document a reduction in time spent treating water as a result of having access to in-line chlorinators. Women were primarily responsible for water collection and treatment in 92% of households, so this reduction in the time presents a possible co-benefit of in-line chlorination to promote gender equity in WASH interventions. Future research should continue incorporating time burden estimates to understand the gender-associated economic and livelihood impacts of WASH programs [11,59].
The introduction of in-line chlorination did not significantly change reported usage of government-provided taps for drinking water, despite reported aversion to taste and smell. Four months post-installation, households in treatment villages were just as likely to report using their tap connection as their primary source as control households. However, about 10% of respondents in the treatment group reported aversion to the taste and smell of chlorinated water. Respondents in treatment villages also anecdotally reported issues with cooking pakhala, a fermented rice meal that is a staple food of Odisha. Residual chlorine in drinking water disinfects microbial communities indiscriminately [62] and can alter the microbial communities responsible for fermentation in foods [63] and the gut microbiome in humans [64–66]. The taste of chlorinated water has been cited as a barrier to adoption of chlorinated drinking water, particularly when users have to dose drinking water themselves [67,68]. Median chlorine taste detection thresholds can also vary globally, though there have been limited studies [33,67,69–72]. Understanding taste detection and acceptability thresholds is important for setting a target chlorine dose which meets communities’ preferences to ensure high adoption. Lowering target chlorine concentrations in response to complaints without knowing if the complaints are associated with true aversion to taste and odor also presents a risk of inadequate disinfection. When individuals can influence water treatment decisions in their community, designing the appropriate messaging and chlorine dosing procedures for new installations is important [33]. While some have hypothesized that consuming chlorinated water over time increases acceptability thresholds [71], there have been no rigorous studies investigating if exposure over time affects the taste detection and acceptability thresholds of chlorinated water. Better understanding of how taste and odor acceptability changes with exposure to chlorinated water would be valuable for designing dosing strategies that maximize adoption, like, for example, starting at a low dose and increasing over some specified amount of time.
Participants in our study area used multiple water sources, a practice which affects exposure to non-chlorinated drinking water. Participants commonly reported using alternative water sources when water was unavailable at their tap connection, which would occur due to intermittent water supply leading to limited availability or when groundwater could not be pumped due to electricity outages. Importantly, we did not observe increased use of alternative water sources after providing chlorinated water to households in the treatment group. Previous studies have highlighted convenience as being a factor in water source selection [73,74], and participants in our study may have continued use of their tap connection because it was conveniently located at their home. Users may also unknowingly switch from a higher quality water source to a low quality source based on taste in other settings. In Dhaka, Bangladesh, Smith et al. found that participants in a chlorinated water taste study were 22–36% more likely to drink water dosed at 0.5 mg/L rather than 1.5 mg/L, and dosing at 0.5 mg/L minimized fecal contamination exposure among participants when compared to higher chlorine concentrations when source switching is practiced [52]. Having multiple water sources available for use can also increase resilience to water supply disruptions caused by intermittent water supply, climate-related events, or humanitarian disasters and emergencies [73,75], but can significantly increase exposure to fecal contamination if those alternative sources are of lower quality [76]. Consuming water from unimproved sources, even a few days out of the year, can significantly elevate exposure to fecal contamination and health risks [36,70]. Not all secondary sources may be compatible with in-line chlorination, and other water treatment methods may need to be considered for community-wide coverage in some settings. The factors contributing to water source switching for specific contexts, like cost, convenience, and taste, should be considered when designing dosing strategies to promote adoption of chlorinated water and prevent source switching to lower quality sources.
Operational considerations for in-line chlorination
Although the in-line chlorination devices effectively chlorinated water, we faced several operational challenges which led to inconsistent dosing or no dosing at all. First, although acceptance was generally high with only around 10% of respondents reporting issues with taste or smell, pump operators turned off devices at least once in all treatment villages in response to complaints. Satisfaction and taste perceptions were self-reported and thus subject to potential reporting bias. Gram Vikas responded to complaints by visiting and talking with village members, but this was not always successful at preventing pump operators from turning off the chlorinators. Community members in one village decided to have their chlorinator uninstalled because of taste and smell aversion following a community-wide meeting with Gram Vikas in March 2024. In another village, the pump operator turned off the chlorinator after receiving repeated complaints about the taste and smell of the water from one household. Gram Vikas canvassed other households to understand the extent of complaints and learned that most households were in favor of the chlorinated water, but the pump operator still decided to turn off the device. Second, chlorine tablet deliveries to villages were occasionally delayed and led to no dosing events after refills were missed. Other studies have reported issues with consistent chlorine dosing including missed or delayed chlorine refills, clogging in the system due to precipitates from calcium hypochlorite tablets, damage to the water supply pipeline, broken parts, physio-chemical properties of water affecting tablet dissolution rates and chlorine demand, or decisions by communities to not purchase chlorine refills [40–42,77–79]. We found similar variation in dosing between CTI-8 and PurAll 100 dosers in this study, which was likely driven by their similar designs. Another design constraint of chlorine tablet dosers is that they do not include a proportional dosing mechanism for pressurized flow, unlike other in-line chlorination technologies; dosing is controlled through gate valve adjustment to divert water through a bypass [17]. Previous bench-scale testing of tablet dosers observed changes in chlorine dosing as flow rate varied through the doser [38]. Certain water supply systems, like those relying on solar powered pumps, could observe greater variation in flow and dosing as compared to the infrastructure in our study.
It has been previously hypothesized that inconsistent chlorine dosing could impact how users perceive chlorinated water and may reduce the likelihood that people become accustomed to drinking chlorinated water [17]. We did not measure compounds known to cause chlorinous taste or odors, like chloramines formed by reactions between ammonia and chlorine prior to breakpoint chlorination, though we did observe similar free and total chlorine residual concentrations (mean difference of 0.06 mg/L between paired samples). We also did not find substantial chlorine decay in the distribution pipeline between the nearest and farthest tap connections in the network (average difference of 0.11 mg/L). We hypothesize this is due to a low residence time of less than two hours for chlorinated water in the village distribution network. We did observe variation in average chlorine concentrations (SD = 0.33 mg/L) over time, though it is unclear if this magnitude of variation meaningfully changes taste perceptions of chlorinated water. In addition to communication strategies for addressing complaints, future implementations of in-line chlorination should refine operational guidelines to address communities’ taste and smell preferences and build the capacity of operators to ensure consistent chlorination.
These challenges highlight that achieving consistent chlorination will require community sensitization and systems to create incentives for operators to maintain, refill, and calibrate devices. In our study, pump operators did not operate or maintain the chlorinators and we did not provide financial compensation to them based on guidance from the local Rural Water Supply and Sanitation Department. Pump operators therefore had limited incentives to keep devices switched on if some community members complained. During the study, we detected no-dosing events quickly through regular monitoring of water quality. A comparison study of manual versus in-line chlorination in Ghana similarly found that each chlorination approach performed best when an incentivized operator strictly adhered to dosing protocols and water quality was monitored consistently [43]. The study found manual chlorination to be less effective than in-line chlorination at consistent dosing [43]. Regardless of approach, research to date suggests that the delivery of in-line chlorination at scale will require consistent monitoring, incentives, and technical support for operators.
Pathways for scaling in-line chlorination
Other implementations of in-line chlorination have also achieved consistent chlorination in different infrastructure scenarios [41–43,78]. Scaling in-line chlorination sustainably requires ongoing funding, as well as management systems to incentivize consistent refills and maintenance. Financial models combining water supply and treatment would need to account for the added costs of water treatment per volume of water treated, which we estimated to be between $0.004-$0.04 USD per 1,000 liters of treated water in this study. Other in-line chlorination evaluations in Nepal and Ghana included additional operational costs (e.g., operator salaries, electricity for pumping, maintenance, etc.) and estimated the treatment cost rate to be $0.06-$0.09 USD per 1,000 liters [41,43]. However, there are several potential pathways to scale, including roles for both the public and private sector in designing sustainable financial models.
First, governments could decide to fund in-line chlorination. In October 2023, the Jal Jeevan Mission issued a national advisory on in-line chlorination adoption in single village schemes. After receiving preliminary results from this study and others (including pilots by NGO Tata Trusts in Assam and by Evidence Action in Andhra Pradesh) Jal Jeevan Mission published a handbook on water quality in piped water schemes in December 2024 recommending that “all states acquire chlorination systems” for rural piped water supply [80]. Some state governments have procured in-line chlorination devices at scale or initiated procurement. For example, Maharashtra has issued orders to construct over 17,000 electro-chlorination plants [81]. Chhattisgarh has issued an Expression of Interest seeking electrochlorinator manufacturers [82]. Meghalaya has requested quotes for electrochlorinator installation and maintenance and is currently engaged in the bidding process [83]. Here we demonstrated that chlorine tablet dosers can successfully dose chlorine under pressurized conditions, expanding the potential market for chlorine tablet dosers and providing a pathway for scaling water treatment under the Jal Jeevan Mission. To our knowledge, several state governments have pilot tested tablet dosers and other ILC devices and are considering scaling up at the time of this writing [84]. Odisha is also engaged in efforts to incorporate ILC into rural drinking water systems following this study.
Second, bundled payments for water treatment and water access could help to fund chlorination, as willingness to pay for water access is often higher than that of water treatment [16]. Lindmark et al. (2023) evaluated a circuit-rider model for operating and maintaining in-line chlorination in rural Honduras and found that local government bodies charged tariffs for water access, part of which they used to purchase chlorine tablets from an NGO [78]. The service provider’s salaries were supported by chlorine tablet sales, and their continuous service delivery led to more than 77% of water samples having chlorine concentrations greater than 0.2 mg/L over the last 9 years [78]. Landlords and water kiosk owners operating community water systems have also demonstrated ability and willingness to pay for in-line chlorination devices and refills [85,86]. In Bangladesh, a study documented that most landlords were initially willing and able to pay a monthly service fee covering the cost of installing and operating in-line chlorination devices [85]. However, timely payments decreased over the service period, particularly for lower-income compounds. In Kenya, 27% of kiosk owners purchased an in-line chlorination device when offered the opportunity to buy [86]. Six of these seven kiosks paid in full and 66% of their customers reported buying chlorinated water (they had the option to purchase from either non-chlorinated or chlorinated taps). Programs selling water treatment to intermediaries like kiosk owners or landlords could be supplemented with public subsidy.
Third, performance-based contracts with subsidies from governments or aid organizations could be used to incentivize utilities to use in-line chlorination by making payments conditional on reported water quality test results [87]. In Malawi, the grant-funded organization Uptime made payments to a service provider based on the proportion of time hand pumps were reported functional, resulting in >95% uptime in the program area [88]. In 2025, Uptime reported 125,000 functioning water points with greater than 96% uptime across their global service areas in Africa, Asia, and Latin America with an annual payment of $0.42 per person served [89]. In the context of in-line chlorination, water service providers could receive payments based on achieving a proportion of positive chlorine tests above a threshold at the point of collection in their water delivery system. Delivery models that incentivize consistent water treatment alongside water supply delivery are critical for scale up of in-line chlorination.
Limitations
Our study has several limitations. First, the prevalence of fecal contamination was imbalanced at baseline in piped water between treatment and control villages, though this imbalance was not statistically significant after adjusting for block stratification and results were similar after controlling for baseline measurements in our models. Second, although we randomized the allocation of in-line chlorination, we did not randomize which villages received the PurAll 100 device versus the CTI-8. However, we did not observe any differences in performance between the technologies. We also did not evaluate in-line chlorination in water sources with a measured turbidity greater than 5 NTUs, which precludes the generalizability of our results to more turbid water sources, like surface water. Similarly, water sources with different physio-chemical parameters (e.g., water sources with high turbidity, pH greater than 8, or elevated levels of hardness, alkalinity, or natural organic matter) could have higher chlorine demand and reduced disinfection performance as compared to our study site, and higher CT (concentration ✕ time) values would be required to observe the same level of disinfection. In water sources with a pH of 6 and temperature of 5 degrees Celsius, the CT value for 99% inactivation of E. coli is 0.04 mg-min/L [90,91]. Finally, we collected water samples after the water supply had been on for at least 5 minutes already, but in intermittent water supply schemes, the microbiological water quality is often at its worst during the first minutes of supply because of a first flush effect [92], meaning we could have underestimated the magnitude of fecal contamination.
Conclusion
This study suggests that in-line chlorination can improve water quality by reducing fecal contamination, lower the time burden of water treatment on individuals (usually women), and lead to increased and sustained user adoption of water treatment [11,14,15,20]. Our findings also indicate in-line chlorination of drinking water should be considered as a strategy for reducing human exposure to antibiotic resistant bacteria. We recommend future in-line chlorination interventions set a target chlorine concentration in the middle of the acceptable range (e.g., 0.5 mg/L to achieve a range of 0.2 mg/L to 0.8 mg/L) for a given context to account for variability in the chlorine demand of source water and device dosing. To increase the scale and impact of in-line chlorination, operational procedures need to be developed for implementers to fit their context’s technical and social constraints. Future research, policy, and scaling efforts focused on in-line chlorination should also consider pathways to achieve sustainable financing through governmental programs, bundled payments through existing water service providers, or by generating new incentives for water service providers through performance-based contracting.
Supporting information
S1 File. Additional details on primary study outcomes.
https://doi.org/10.1371/journal.pwat.0000440.s001
(DOCX)
S2 File. Baseline free and total chlorine testing.
https://doi.org/10.1371/journal.pwat.0000440.s002
(DOCX)
S1 Table. Follow-up survey and census results.
https://doi.org/10.1371/journal.pwat.0000440.s003
(DOCX)
S2 Table. Chlorine monitoring results stratified by village.
https://doi.org/10.1371/journal.pwat.0000440.s004
(DOCX)
S1 Fig. Completed PurAll and CTI-8 ILC installations.
https://doi.org/10.1371/journal.pwat.0000440.s005
(TIF)
S2 Fig. Proportion of water samples with a presence of E. coli stratified by sample type and free chlorine concentration.
https://doi.org/10.1371/journal.pwat.0000440.s006
(TIF)
S3 Fig. Estimated total coliform and E. coli reductions for every 0.1 mg/L increase in free chlorine concentration.
https://doi.org/10.1371/journal.pwat.0000440.s007
(TIF)
S3 Table. Linear regression model results comparing increasing chlorine concentration on microbial contamination.
https://doi.org/10.1371/journal.pwat.0000440.s008
(DOCX)
S4 Fig. Free chlorine concentrations versus E. coli MPN/100 mL for tap and stored water samples.
https://doi.org/10.1371/journal.pwat.0000440.s009
(TIF)
S5 Fig. Impact of increasing free chlorine concentrations in tap water on the proportion of stored samples testing positive for free chlorine.
https://doi.org/10.1371/journal.pwat.0000440.s010
(TIF)
S1 Checklist. Inclusivity in global research questionnaire.
https://doi.org/10.1371/journal.pwat.0000440.s011
(DOCX)
Acknowledgments
We sincerely thank the study participants for their involvement in this study. Thanks to the J-PAL South Asia team for their leadership in data collection including Archi Gupta, Archana M V, Nitin Kanakaraj, Prasanta Panda, and the entire data collection team. Thanks to the Gram Vikas team for their support in co-designing the intervention and implementing it, including Jobin Chacko, Varun Namineni, Debashis Mohapatra, Dibya Ranjan, Narottam Sethi, Kalicharan Panda, and Liby Johnson. Thanks to Luiza Andrade and Witold Więcek for advising and reviewing data analysis methods. Thanks to Arthur Baker for providing feedback on the original manuscript discussion. Special thanks to Akanksha Saletore, Tavleen Singh, Shashank Patil, Michelle Cherian, Astha Vohra, and Niharika Bhagavatula for their leadership and support in conducting the study.
References
- 1.
World Health Organization, UNICEF. State of the World’s Drinking Water. 2022. Report No.: 9789240060807.
- 2. Greenwood EE, Lauber T, Van Den Hoogen J, Donmez A, Bain RES, Johnston R. Mapping safe drinking water use in low- and middle-income countries. Science. 2024;385(6710):784–90.
- 3. Clasen TF, Alexander KT, Sinclair D, Boisson S, Peletz R, Chang HH, et al. Interventions to improve water quality for preventing diarrhoea. Cochrane Database Syst Rev. 2015;2015(10):CD004794. pmid:26488938
- 4.
Kremer M, Luby S, Maertens R, Tan B, Więcek W. Water treatment and child mortality: a meta-analysis and cost-effectiveness analysis. 2023.
- 5.
WHO. Global Tricycle Surveillance – ESBL E.coli - Integrated Global Surveillance on ESBL-producing E. coli Using a “One Health” Approach: Implementation and Opportunities. 2021. 76 p. (World Health Organization, Global Antimicrobial Resistance Surveillance System (GLASS), Surveillance Prevention and Control).
- 6. Puspandari N, Sunarno S, Febrianti T, Febriyana D, Saraswati RD, Rooslamiati I, et al. Extended spectrum beta-lactamase-producing Escherichia coli surveillance in the human, food chain, and environment sectors: Tricycle project (pilot) in Indonesia. One Health. 2021;13:100331. pmid:34632041
- 7. Murray CJL, Ikuta KS, Sharara F, Swetschinski L, Robles Aguilar G, Gray A, et al. Global burden of bacterial antimicrobial resistance in 2019: a systematic analysis. The Lancet. 2022;399(10325):629–55.
- 8. Huijbers PMC, Flach C-F, Larsson DGJ. A conceptual framework for the environmental surveillance of antibiotics and antibiotic resistance. Environ Int. 2019;130:104880. pmid:31220750
- 9. Nadimpalli ML, Marks SJ, Montealegre MC, Gilman RH, Pajuelo MJ, Saito M, et al. Urban informal settlements as hotspots of antimicrobial resistance and the need to curb environmental transmission. Nat Microbiol. 2020;5(6):787–95. pmid:32467623
- 10. Crider YS, Tsuchiya M, Mukundwa M, Ray I, Pickering AJ. Adoption of Point-of-Use Chlorination for Household Drinking Water Treatment: A Systematic Review. Environ Health Perspect. 2023;131(1):16001. pmid:36715546
- 11. Cherukumilli K, Ray I, Pickering AJ. Evaluating the hidden costs of drinking water treatment technologies. Nat Water. 2023;1(4):319–27.
- 12. Luby SP, Rahman M, Arnold BF, Unicomb L, Ashraf S, Winch PJ, et al. Effects of water quality, sanitation, handwashing, and nutritional interventions on diarrhoea and child growth in rural Bangladesh: a cluster randomised controlled trial. Lancet Glob Health. 2018;6(3):e302–15. pmid:29396217
- 13. Null C, Stewart CP, Pickering AJ, Dentz HN, Arnold BF, Arnold CD, et al. Effects of water quality, sanitation, handwashing, and nutritional interventions on diarrhoea and child growth in rural Kenya: a cluster-randomised controlled trial. Lancet Glob Health. 2018;6(3):e316–29. pmid:29396219
- 14. Pickering AJ, Null C, Winch PJ, Mangwadu G, Arnold BF, Prendergast AJ, et al. The WASH Benefits and SHINE trials: interpretation of WASH intervention effects on linear growth and diarrhoea. Lancet Glob Health. 2019;7(8):e1139–46. pmid:31303300
- 15. Boisson S, Stevenson M, Shapiro L, Kumar V, Singh LP, Ward D, et al. Effect of household-based drinking water chlorination on diarrhoea among children under five in Orissa, India: a double-blind randomised placebo-controlled trial. PLoS Med. 2013;10(8):e1001497. pmid:23976883
- 16. Ahuja A, Kremer M, Zwane AP. Providing safe water: evidence from randomized evaluations. Annu Rev Resour Econ. 2010;2:237–56.
- 17. Lindmark M, Cherukumilli K, Crider YS, Marcenac P, Lozier M, Voth-Gaeddert L, et al. Passive In-Line Chlorination for Drinking Water Disinfection: A Critical Review. Environ Sci Technol. 2022;56(13):9164–81. pmid:35700262
- 18. Cutler D, Miller G. The role of public health improvements in health advances: the twentieth-century United States. Demography. 2005;42(1):1–22. pmid:15782893
- 19.
Mangrove Water. In-Line Chlorination Playbook: Guidance on Installing, Operating, and Maintaining In-Line Chlorination Devices to Disinfect Drinking Water [Internet]. 2025 [cited 2025 Dec 12]. Available from: www.mangrovewater.org/resources
- 20. Pickering AJ, Crider Y, Sultana S, Swarthout J, Goddard FG, Anjerul Islam S, et al. Effect of in-line drinking water chlorination at the point of collection on child diarrhoea in urban Bangladesh: a double-blind, cluster-randomised controlled trial. Lancet Glob Health. 2019;7(9):e1247–56. pmid:31402005
- 21. Cherukumilli K, Bain R, Chen Y, Pickering AJ. Estimating the global target market for passive chlorination. Environ Sci Technol Lett. 2023;10(1):105–10.
- 22. Singh A, Naik G. Rural drinking water supply program and societal development: Evidence from the early implementation phase of India’s Jal Jeevan Mission. PLoS One. 2024;19(11):e0312144. pmid:39570840
- 23.
Jal Jeevan Mission extended till 2028 with enhanced budget, focus on quality and sustainability. The Times of India [Internet]. 2025 Feb 1 [cited 2025 Feb 14]; Available from: https://timesofindia.indiatimes.com/business/india-business/jal-jeevan-mission-extended-till-2028-with-enhanced-budget-focus-on-quality-and-sustainability/articleshow/117820574.cms
- 24.
JJM Dashboard [Internet]. [cited 2024 Dec 18]. Available from: https://ejalshakti.gov.in/jjmreport/JJMIndia.aspx
- 25.
Ministry of Jal Shakti. Operational Guidelines for the Implementation of Jal Jeevan Mission Har Ghar Jal [Internet]. 2020. Available from: https://jaljeevanmission.gov.in/guidelines
- 26. Kumpel E, Nelson KL. Comparing microbial water quality in an intermittent and continuous piped water supply. Water Res. 2013;47(14):5176–88. pmid:23866140
- 27. Bivins A, Lowry S, Murphy HM, Borchardt M, Coyte R, Labhasetwar P, et al. Waterborne pathogen monitoring in Jaipur, India reveals potential microbial risks of urban groundwater supply. NPJ Clean Water. 2020;3(1).
- 28. Bivins AW, Sumner T, Kumpel E, Howard G, Cumming O, Ross I, et al. Estimating Infection Risks and the Global Burden of Diarrheal Disease Attributable to Intermittent Water Supply Using QMRA. Environ Sci Technol. 2017;51(13):7542–51. pmid:28582618
- 29. LeChevallier MW, Evans TM, Seidler RJ. Effect of turbidity on chlorination efficiency and bacterial persistence in drinking water. Appl Environ Microbiol. 1981;42(1):159–67. pmid:7259162
- 30. Crump JA, Okoth GO, Slutsker L, Ogaja DO, Keswick BH, Luby SP. Effect of point-of-use disinfection, flocculation and combined flocculation-disinfection on drinking water quality in western Kenya. J Appl Microbiol. 2004;97(1):225–31. pmid:15186460
- 31.
Easol Pvt.Ltd [Internet]. [cited 2024 Dec 9]. Available from: https://www.easol.in/pureall-introduction
- 32. Jacob F, Taflin C. The CTI-8 Chlorinator. Available from: chrome-extension://efaidnbmnnnibpcajpcglclefindmkaj/https://biorealis.com/OMV/files/CTI8%20InformationManual11.1-pdf.pdf
- 33. Crider Y, Sultana S, Unicomb L, Davis J, Luby SP, Pickering AJ. Can you taste it? Taste detection and acceptability thresholds for chlorine residual in drinking water in Dhaka, Bangladesh. Sci Total Environ. 2018;613–614:840–6. pmid:28942317
- 34.
WHO (World Health Organization). Guidelines for drinking-water quality: fourth edition incorporating the first addendum. 2017.
- 35. Hornsby G, Ibitoye TD, Keelara S, Harris A. Validation of a modified IDEXX defined-substrate assay for detection of antimicrobial resistant E. coli in environmental reservoirs. Environ Sci Process Impacts. 2023;25(1):37–43. pmid:36562251
- 36. Daly SW, Harris AR. Modeling Exposure to Fecal Contamination in Drinking Water due to Multiple Water Source Use. Environ Sci Technol. 2022;56(6):3419–29. pmid:35239319
- 37. Chik AHS, Schmidt PJ, Emelko MB. Learning Something From Nothing: The Critical Importance of Rethinking Microbial Non-detects. Front Microbiol [Internet]. 2018 Oct 5 [cited 2025 Jan 6];9. Available from: https://www.frontiersin.org/journals/microbiology/articles/10.3389/fmicb.2018.02304/full
- 38. Martin A. Evaluation of Tablet Chlorinator for a Rural Haitian Water Treatment System—Computational Modeling and Laboratory Testing [Internet]. 2020. Available from: https://open.clemson.edu/all_theses/3426
- 39. Pickering AJ, Crider Y, Amin N, Bauza V, Unicomb L, Davis J, et al. Differences in field effectiveness and adoption between a novel automated chlorination system and household manual chlorination of drinking water in Dhaka, Bangladesh: a randomized controlled trial. PLoS One. 2015;10(3):e0118397. pmid:25734448
- 40. Lukas Dössegger LD, Alan Tournefier AT, Laura Germann LG, Nicola Gärtner NG, Timon Huonder TH, Cosmas Etenu CE, et al. Assessment of low-cost, non-electrically powered chlorination devices for gravity-driven membrane water kiosks in eastern Uganda. Waterlines. 2021;40(2):92–106.
- 41. Crider YS, Sainju S, Shrestha R, Clair-Caliot G, Schertenleib A, Kunwar BM, et al. Evaluation of System-Level, Passive Chlorination in Gravity-Fed Piped Water Systems in Rural Nepal. Environ Sci Technol. 2022;56(19):13985–95. pmid:36125807
- 42. Locher JM, Robinson DT, Canú EN, Sanchez G, Herrera N, Muj MS, et al. Assessment of a local and low-cost passive in-line chlorination device in rural Guatemala. PLOS Water. 2024;3(9):e0000255.
- 43. Delaire C, Marshall K, Usowicz M, Mahin T, Kwaah D, Yachori B, et al. Comparison of passive and manual chlorination in small piped water networks in rural Ghana: Technical performance, ease-of-use, and cost. PLOS Water. 2024;3(10):e0000295.
- 44. Richardson SD, Plewa MJ, Wagner ED, Schoeny R, DeMarini DM. Occurrence, genotoxicity, and carcinogenicity of regulated and emerging disinfection by-products in drinking water: a review and roadmap for research. Mutat Res Mutat Res. 2007;636(1):178–242.
- 45. Richardson SD, Kimura SY. Water Analysis: Emerging Contaminants and Current Issues. Anal Chem. 2020;92(1):473–505. pmid:31825597
- 46. Helte E, Söderlund F, Säve-Söderbergh M, Larsson SC, Åkesson A. Exposure to Drinking Water Trihalomethanes and Risk of Cancer: A Systematic Review of the Epidemiologic Evidence and Dose-Response Meta-Analysis. Environ Health Perspect. 2025;133(1):16001. pmid:39837568
- 47. Furst KE, Coyte RM, Wood M, Vengosh A, Mitch WA. Disinfection byproducts in Rajasthan, India: are trihalomethanes a sufficient indicator of disinfection byproduct exposure in low-income countries? Environ Sci Technol. 2019;53(20):12007–17.
- 48. Wahman DG, Alexander MT, Dugan AG. Chlorinated Cyanurates in Drinking Water: Measurement Bias, Stability, and Disinfectant Byproduct Formation. AWWA Water Sci. 2019;1(2):10.1002/aws2.1133. pmid:31058266
- 49. Adusei KB, Tanveer HU, Kralles ZT, Furst KE. Enhanced Formation of Brominated and Nitrogenous Disinfection Byproducts in Drinking Water Disinfection with Chlorocyanurates. Environ Sci Technol. 2026;60(1):1357–67. pmid:41418812
- 50. Furst KE, Smith DW, Bhatta LR, Islam M, Sultana S, Rahman M. Effects of Intrusion on Disinfection Byproduct Formation in Intermittent Distribution Systems. ACS EST Water. 2022;2(5):807–16.
- 51. Roberts T, Kumpel E, Rajesh L, Lanzarini-Lopes M, Reckhow D, Chavarria KA. Impacts of wastewater intrusion on disinfection byproduct formation: An experimental study. PLOS Water. 2025;4(4):e0000273.
- 52. Smith DW, Islam M, Furst KE, Mustaree S, Crider YS, Akter N, et al. Chlorine taste can increase simulated exposure to both fecal contamination and disinfection byproducts in water supplies. Water Res. 2021;207:117806. pmid:34768105
- 53. Furst KE, Pecson BM, Webber BD, Mitch WA. Tradeoffs between pathogen inactivation and disinfection byproduct formation during sequential chlorine and chloramine disinfection for wastewater reuse. Water Res. 2018;143:579–88. pmid:30015098
- 54. Furst KE, Smith DW. Disinfection byproducts in low-income communities. Curr Opin Environ Sci Health. 2025;48:100683.
- 55. LeChevallier MW, Prosser T, Stevens M. Opportunistic pathogens in drinking water distribution systems—A review. Microorganisms. 2024;12(5):916.
- 56. Wang H, Edwards M, Falkinham JO, Pruden A. Molecular survey of the occurrence of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa, and amoeba hosts in two chloraminated drinking water distribution systems. Applied and Environmental Microbiology. 2012;78(17):6285–94.
- 57. Rangel JM, Lopez B, Mejia MA, Mendoza C, Luby S. A novel technology to improve drinking water quality: a microbiological evaluation of in-home flocculation and chlorination in rural Guatemala. J Water Health. 2003;1(1):15–22.
- 58. Caruso BA, Sinharoy SS. Gender data gaps represent missed opportunities in WASH. Lancet Glob Health. 2019;7(12):e1617. pmid:31708141
- 59. Caruso BA, Ballard AM, Sobolik J, Patrick M, Dsouza J, Sinharoy SS, et al. Systematic re-review of WASH trials to assess women’s engagement in intervention delivery and research activities. Nat Water. 2024;2(9):827–36. pmid:39309371
- 60. Winter JC, Darmstadt GL, Davis J. The role of piped water supplies in advancing health, economic development, and gender equality in rural communities. Soc Sci Med. 2021;270:113599.
- 61. Burt Z, Ercümen A, Billava N, Ray I. From intermittent to continuous service: Costs, benefits, equity and sustainability of water system reforms in Hubli-Dharwad, India. 2018 Sep 1 [cited 2025 Feb 7]; Available from: https://escholarship.org/uc/item/8ph0b5f8
- 62. Fish KE, Reeves-McLaren N, Husband S, Boxall J. Unchartered waters: the unintended impacts of residual chlorine on water quality and biofilms. NPJ Biofilms Microbiomes. 2020;6(1):34. pmid:32978404
- 63. Lau P, Jain S, Perron GG. Water chlorination increases the relative abundance of an antibiotic resistance marker in developing sourdough starters. Microbiol Spectr. 2024;12(11):e0112123. pmid:39283274
- 64. Martino D. The effects of chlorinated drinking water on the assembly of the intestinal microbiome. Challenges. 2019;10(1):10.
- 65. Nadimpalli ML, Lanza VF, Montealegre MC, Sultana S, Fuhrmeister ER, Worby CJ, et al. Drinking water chlorination has minor effects on the intestinal flora and resistomes of Bangladeshi children. Nat Microbiol. 2022;7(5):620–9. pmid:35422497
- 66. Parkin K, Christophersen CT, Verhasselt V, Palmer DJ, Cooper MN, Prescott SL, et al. Chlorinated Drinking Water Exposure Enriches Antimicrobial Resistance Pathways in the Infant Gut Microbiome: A Randomized Trial [Internet]. medRxiv; 2025 [cited 2025 Dec 12]. p. 2024.09.15.24313601. Available from: https://www.medrxiv.org/content/10.1101/2024.09.15.24313601v2
- 67. Luby SP, Mendoza C, Keswick BH, Chiller TM, Hoekstra RM. Difficulties in bringing point-of-use water treatment to scale in rural Guatemala. Am J Trop Med Hyg. 2008;78(3):382.
- 68. Freeman MC, Quick RE, Abbott DP, Ogutu P, Rheingans R. Increasing equity of access to point-of-use water treatment products through social marketing and entrepreneurship: a case study in western Kenya. J Water Health. 2009;7(3):527–34.
- 69. Sara Flanagan SF, Xiaoguang Meng XM, Yan Zheng YZ. Increasing acceptance of chlorination for household water treatment: observations from Bangladesh. Waterlines. 2013;32(2):125–34.
- 70. Osler AL, Alfredo KA, Mihelcic JR. Chlorine Water Taste Threshold and Acceptability among Indigenous and Non-Indigenous Populations in Rural Panama. Environ Sci Technol. 2024;58(12):5548–56. pmid:38471095
- 71. Piriou P, Devesa R, Puget S, Thomas-Danguin T, Zraick F. Evidence of regional differences in chlorine perception by consumers: sensitivity differences or habituation? J Water Supply Res Tec. 2014;64(7):783–92.
- 72. Heylen C, String G, Naliyongo D, Ali SI, Brown J, Ogira V, et al. Evaluating chlorine taste and odor acceptability to inform drinking water chlorination in humanitarian settings: Lessons from trials in Uganda. PLOS Water. 2025;4(2):e0000267.
- 73. Daly S, Lowe J, Hornsby G, Harris A. Multiple water source use in low- and middle-income countries: a systematic review. J Water Health. 2021.
- 74. Grönwall J. Self-supply and accountability: to govern or not to govern groundwater for the (peri-) urban poor in Accra, Ghana. Environ Earth Sci. 2016;75(16):1163.
- 75. Elliott M, Foster T, MacDonald MC, Harris AR, Schwab KJ, Hadwen WL. Addressing how multiple household water sources and uses build water resilience and support sustainable development. NPJ Clean Water. 2019;2(1).
- 76. Hunter PR, Zmirou-Navier D, Hartemann P. Estimating the impact on health of poor reliability of drinking water interventions in developing countries. Sci Total Environ. 2009;407(8):2621–4. pmid:19193396
- 77. Orner KD, Calvo A, Zhang J, Mihelcic JR. Effectiveness of in-line chlorination in a developing world gravity-flow water supply. Waterlines. 2017;36(2):167–82.
- 78. Lindmark M, Meier W, Calix D, Just C. Performance of Community Water Board-Managed Passive In-Line Chlorinators Supported by a Circuit Rider Program in Rural Honduras. ACS ES T Water. 2023;3(12):4011–9. pmid:38094914
- 79. Rayner J, Yates T, Joseph M, Lantagne D. Sustained effectiveness of automatic chlorinators installed in community-scale water distribution systems during an emergency recovery project in Haiti. J Water Sanit Hyg Dev. 2016;6(4):602–12.
- 80.
Jal Jeevan Mission. Concise Handbook for Monitoring Water Quality of Piped Drinking Water Supply to Rural Households [Internet]. 2024 [cited 2025 Apr 18]. Available from: https://jaljeevanmission.gov.in/sites/default/files/wq/handbook-for-monitoring-wq-of-piped-drinking-water.pdf
- 81.
Mission Director, State Water and Sanitation Mission, Government of Maharashtra. Appointment of specialized agencies for Electrochlorination systems. Work Order Phase 2 for Tender. [Internet]. 2022. Available from: https://mahatenders.gov.in/
- 82.
Public Health Engineering Department, Government of Chhattisgarh. Expression of Interest for Empanelment of manufacturers with JJM for Electro Chlorinator System which is to be used for potable water supply under Jal Jeevan Mission programme in the state [Internet]. 2023. Available from: https://phed.cg.gov.in/sites/default/files/Elctroclorinator_F_.pdf
- 83.
GOVERNMENT OF MEGHALAYA OFFICE OF THE CHIEF ENGINEER, PHE, MEGHALAYA SHILLONG. Notice Inviting Quotation for Supply, Installation and Maintenance of Electro Chlorination System in Meghalaya [Internet]. 2024. Available from: https://megphed.gov.in/notices/NIT19January2024.pdf
- 84.
Evidence Action [Internet]. 2025 [cited 2025 Jun 13]. Where the pipes lead. Available from: https://www.evidenceaction.org/insights/where-the-pipes-lead
- 85. Smith DW, Sultana S, Crider YS, Islam SA, Swarthout JM, Goddard FGB, et al. Effective Demand for In-Line Chlorination Bundled with Rental Housing in Dhaka, Bangladesh. Environ Sci Technol. 2021;55(18):12471–82. pmid:34498866
- 86. Powers JE, McMurry C, Gannon S, Drolet A, Oremo J, Klein L, et al. Design, performance, and demand for a novel in-line chlorine doser to increase safe water access. NPJ Clean Water. 2021;4(1).
- 87. Charles K, Nowicki S, Armstrong A, Hope R, McNicholl D, Nilsson K. Results-based funding for safe drinking water services. 2023 [cited 2025 Jan 8]; Available from: https://ora.ox.ac.uk/objects/uuid:aa9a7489-b50c-4af9-a088-dc5b35ffe377
- 88.
Uptime. Malawi handpump pilot: Suitability for results-based contracting and the path to scale [Internet]. Available from: https://www.uptimewater.org/s/Malawi-handpump-pilot-Suitability-for-results-based-contracting-and-the-path-to-scale.pdf
- 89.
Uptime [Internet]. [cited 2025 May 18]. Available from: https://www.uptimewater.com/global-dashboard
- 90. Sobsey MD. Inactivation of Health-Related Microorganisms in Water by Disinfection Processes. Water Science and Technology. 1989;21(3):179–95.
- 91.
Gerba CP. Chapter 29 - Disinfection. In: Pepper IL, Gerba CP, Gentry TJ, editors. Environmental Microbiology (Third Edition) [Internet]. San Diego: Academic Press; 2015. p. 645–62. Available from: https://www.sciencedirect.com/science/article/pii/B9780123946263000296
- 92. Kumpel E, Nelson KL. Mechanisms affecting water quality in an intermittent piped water supply. Environ Sci Technol. 2014;48(5):2766–75. pmid:24459990