Figures
Abstract
Background
Longer outpatient studies have demonstrated that hybrid closed loop (HCL) use has led to a concomitant reduction in glycated hemoglobin(HbA1c) by 0.3%–0.7%. However, reports have also indicated that HbA1c levels are not declined in the long-term use of HCL. Therefore, we wonder that 3 months use of HCL could improve glycated hemoglobin levels in adolescents and children with T1D.
Methods
Relevant studies were searched electronically in the Cochrane Library, PubMed, and Embase utilizing the key words “Pediatrics or Child or Adolescent”, “Insulin Infusion Systems” and “Diabetes Mellitus” from inception to 17th March 2024 to evaluate the performance of HCL on HbA1c in adolescents, and children with T1D.
Results
Nine studies involving 927 patients were identified. Three months use of HCL show a beneficial effect on HbA1c management (p <0.001) as compared to standard of care in adolescents and children with T1D, without evidence of heterogeneity between articles (I2 = 40%, p = 0.10). HCL did significantly increase the overall average percentage of hypoglycemic time between 70 and 180 mg/dL (TIR) (p <0.001; I2 = 51%). HCL did not show a beneficial effect on hypoglycemic time <70 mg/dL and <54 mg/dL (p >0.05). The overall percentage of hyperglycemic time was significantly decreased in HCL group compared to the control group when it was defined as >180 mg/dL (p <0.001; I2 = 83%), >250 mg/dL (p = 0.007, I2 = 86%) and >300 mg/dL (p = 0.005; I2 = 76%). The mean glucose level was significantly decreased by HCL (p <0.001; I2 = 58%), however, no significant difference was found in coefficient of variation of sensor glucose (p = 0.82; I2 = 71%) and daily insulin dose (p = 0.94; I2 <0.001) between the HCL group and the control group.
Conclusions
HCL had a beneficial effect on HbA1c management and TIR without increased hypoglycemic time as compared to standard of care in adolescents and children with T1D when therapy duration of HCL was not less than three months.
Trial number and registry URL
CRD42022367493; https://www.crd.york.ac.uk/PROSPERO, Principal investigator: Zhen-feng Zhou, Date of registration: October 30, 2022.
Citation: WANG Y-y, YING H-m, TIAN F, QIAN X-l, Zhou Z-f (2024) Three months use of Hybrid Closed Loop Systems improves glycated hemoglobin levels in adolescents and children with type 1 diabetes: A meta-analysis. PLoS ONE 19(8): e0308202. https://doi.org/10.1371/journal.pone.0308202
Editor: Timotius Ivan Hariyanto, Pelita Harapan University Faculty of Medicine: Universitas Pelita Harapan Fakultas Kedokteran, INDONESIA
Received: March 29, 2024; Accepted: July 19, 2024; Published: August 12, 2024
Copyright: © 2024 WANG et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All data analysed during this study are collected from published articles [Table 1].
Funding: The author(s) received no specific funding for this work.
Competing interests: The authors have declared that no competing interests exist.
Abbreviations: BMI, body mass index; CI, confidence interval; DKA, diabetic ketoacidosis; HCL, Closed-Loop Systems; MD, mean difference; OR, odds ratio; PLGS, predictive low glucose suspend systems; RCTs, randomized controlled studies; RR, relative risk; SAP, sensor-augmented pump; SMD, standardised mean difference; T1D, type 1 diabetes; TIR, the percent time in range
Introduction
The overall annual incidence of type 1 diabetes (T1D) was reported to be increasing by around 3% in adolescents and children [1]. Cognition and brain structure can be profoundly impacted if glycemic control is poor controlled in the early course of T1D, particularly in very young children [2, 3]. The 2019 American Diabetes Association guidelines suggest that HbA1c should be control at <7.5% for all children [4]. However, the achievement of this glycemic control goal is affected by several behavioral and developmental factors in adolescents and children [5].
Several new devices have been developed to improve T1D management in recent decades, including real-time continuous glucose monitoring (CGM) devices and other insulin pumps [6], however, the management of HbA1c has actually worsened in adolescents and children over the last 10 years [6–9]. According to the latest ISPAD consensus clinical practice guidelines [10], HCL is strongly recommended for youth with diabetes as it could improve time in range (TIR) by minimizing hypoglycemia and hyperglycemia, and is especially beneficial in the overnight period (level A).
Longer outpatient studies have also demonstrated that HCL use has led to a concomitant reduction in HbA1c by 0.3%–0.7% [11–19]. However, most of the above studies were not randomized clinical trials or HCL administration period was less than 3 months. Previous studies have shown that HbA1c levels decrease in adolescents and adults after at least 3 months of HCL use [20–22]. Furthermore, reports have also indicated that HbA1c levels are not declined in the long-term use of HCL as compared to the control group [23–25].
Recent meta-analysis [26, 27] had also concerned HbA1c of HCL in patients with T1D, however, the recent important studies [8, 9, 11, 22, 24, 28, 29] were not included in those recent meta-analysis [26, 27], we also noticed that one recent meta-analysis [26, 27] included adults with a study period of less than 8 weeks, and the study period of another recent meta-analysis [27] was different from 48 h to 6 months and 40% of follow up were no more than 7days. Therefore, we wonder that at least 3 months use of HCL could improve glycated hemoglobin levels in adolescents and children with T1D.
Materials and methods
We performed this meta-analysis in accordance with the PRISMA [30] and we registered the protocol with PROSPERO (CRD42022367493).
Search strategy
The Cochrane Library, PubMed, and Embase databases were searched from inception to 17th March 2024 by two investigators (Fang TIAN and Hui-min YING) to identity relevant studies.
The following key words were used: “Pediatrics or Child or Adolescent”, “Insulin Infusion Systems” and “Diabetes Mellitus”. A detailed list of search strategies is provided in S1 File. First, two independent reviewers (Fang TIAN and Hui-min YING) excluded irrelevant studies by screening the titles and abstracts. Then, the full texts of the remaining studies were reviewed to ensure that all relevant studies had been evaluated. An independent third author (Xiao-lu QIAN) was consulted to resolve any disagreements between the reviewers.
Study selection and data extraction.
Only randomized controlled studies (RCTs) in the English language were included. Other eligibility criteria were as follows: (a) adolescents and children with T1D; (b) treatment with closed-loop systems; (c) treatment with insulin pump without closed-loop systems in the control group; and (d) duration of study was not less than 12 weeks. Studies with an adult population (above 21 years old), non-RCTs, conference abstracts, case reports and studies with no control group (standard of care) were excluded.
The HCL system was defined as having glucose-sensing technology and algorithm-based insulin delivery including single-hormone (nonadjustable insulin pump systems) or dual-hormone (insulin and glucagon pump systems). The standard of care was confirmed as any kind of standard care provided including sensor-augmented pump (SAP), open-loop and PLGS (predictive low glucose suspend systems).
Two authors (Fang TIAN and Hui-min YING) identified all studies by the above eligibility and exclusion criteria. We extracted the following data: the type of trial, publication year, sex, age, BMI, duration of diabetes, duration of HCL treatment, sample size and glycemic outcomes (Table 1).
Outcome definition [31].
The primary endpoint was the HbA1c level in adolescents and children with T1D at the end of the study period. The secondary outcomes were as follows: the percent time in range (TIR) between 70 and 180 mg/dL, percentage of hypoglycemic time (the sensor glucose defined as <70 mg/dL and < 54 mg/dL) and hyperglycemic time (>180 mg/dL, > 250 mg/dL and > 300 mg/dL), sensor glucose values, coefficient of variation of sensor glucose values, and total daily insulin dose requirement. Furthermore, data on adverse events were collected, including (1) severe hypoglycemia: hypoglycemia needing to be treated as altered consciousness; (2) diabetic ketoacidosis (DKA, defined according to the criteria of the Diabetes Control and Complications Trial); and (3) hyperketonemia. Outcomes were also evaluated in based on segments of the day: daytime (usually defined as 7:00 AM to 11:00 PM) and overnight (usually defined as 11:00 PM to 7:00 AM).
Quality assessment of the included studies.
The risk of bias of each included study was assessed with the Cochrane Collaboration tool by two independent reviewers(Yuan-yuan WANG and Xiao-lu QIAN) [18]. Each study was scored as having “low risk”, “high risk”, or “unclear risk” based on the following criteria: randomization, allocation concealment, blinding of participants and personnel, outcome assessment blinding, incomplete data and selective reporting, and other biases. The Jadad score was also calculated (Table 1 and S2 File). We attempted to contact the authors to obtain any missing data. Studies with missing data were excluded when specific outcomes were compared.
Data synthesis and analysis
The statistical analysis was performed using RevMan 5.3 (RevMan; Copenhagen: The Nordic Cochrane Center, The Cochrane Collaboration, 2014) and STATA (Version 12.0). The effects were expressed as risk ratio (relative risk [RR] or odds ratio [OR]) with 95% confidence interval (CI) and mean difference (MD) with 95% CI for the dichotomous data and continuous data, respectively. A random effects model (M-H heterogeneity) was used to pool data, and I2 statistic >50% and χ2 test ≤ 0.05 were considered to indicate statistical significance. Sensitivity analysis was used to evaluate the robustness of the results. Subgroup analyses and meta-regression analyses were performed to identify the potential sources of heterogeneity. Egger’s and Begg’s tests were used to evaluate publication bias, but they were not suggested if the number of included studies was less than10 [32]. A p value of less than 0.05 was considered to indicate statistical significance and all reported p values were two-tailed.
Sample size calculation and power analysis
The Type I error probability associated with this test of this null hypothesis is 0.05 and we will use a continuity-corrected chi-squared statistic or Fisher’s exact test to evaluate this null hypothesis. This study had only 14.7% power to detect that the HCL group could increase hyperketonemia with sample of 286 patients in the HCL group and 160 patients in the standard of care group. Similarly, the results showed that this study was underpowered (less than 10% power) for identifying the effects of HCL on hypoglycemia, severe hypoglycemia and DKA. The analyses were performed with PS3.0 (Version 3.0, Power and Sample size calculation) software.
Results
Study selection and characteristics
Our search strategy initially yielded 2490 articles. After screening the titles and abstracts, 137 articles remained for full-text screening. The total number of participants was increased due to crossover test designs in which participants were included multiple times. Ultimately, a total of 9 articles involving 927 participants were included in this meta-analysis [8, 9, 11, 14, 22, 24, 25, 28, 29] (Fig 1). The average age was 11 years old, and the sample size was greater than 100 in most studies (6/9, 66.7%) [9, 11, 14, 22, 28, 29]. The HCL was only used in the evenings as an overnight closed-loop in only one (1/9, 11.1%) study [25]; in the remaining studies, the HCL system was in use for 24 hours a day (8/9, 88.9%). The average duration of diabetes was six years.
Risk of bias assessment.
The risks of bias in individual studies and the overall risk of bias are shown in Fig 2 (Fig 2A: risk of bias summary and Fig 2B: risk of bias graph). Although most studies were randomized-control studies (7/9, 77.8%) [8, 9, 14, 22, 24, 28, 29], the risk of bias was difficult to assess in randomized crossover trials (2/9, 22.2%) [11, 25]. Only one study [24] did not provide specific information on random sequence generation and addressed allocation concealment. The risks of performance bias (8/9, 88.9%) and detection bias (6/9, 66.7%) were considered "unclear" in most studies, as no relevant information was provided.
A: risk of bias summary and B: risk of bias graph.
Primary outcomes
HbA1c level.
All included studies [8, 9, 11, 14, 22, 24, 25, 28, 29] with a total of 927 patients compared the efficacy of the HCL group versus the control group to assess the HbA1c level at the end of the study. HCL showed a beneficial effect on HbA1c levels (7.2 ± 1.0 vs. 7.7 ± 1.0%; MD, −0.46, 95% CI, −0.62 to -0.30%; p <0.001, Fig 3) without evidence of heterogeneity between articles (I2 = 40%, p = 0.10; Table 2).
HCL = Hybrid Closed Loop Systems; RR = relative risk; CI = confidence interval.
Sensitivity analysis of HbA1c level.
Sensitivity analyses using the leave one out method revealed that HCLs still showed a beneficial effect on HbA1c levels (S1 Table).
Secondary endpoints
TIR (the percent time in range between 70 and 180 mg/dL).
All included studies [8, 9, 11, 14, 22, 24, 25, 28, 29] with a total of 927 patients compared the safety of the HCL with that of the control group to assess TIR. The percentage of sensor glucose values in TIR was higher in the HCL than in the control overall without evidence of heterogeneity (62.4 ±14.8 vs. 50.6 ±15.2%; MD, 9.96; 95% CI, 7.63 to 12.30%, p <0.001; I2 = 51%, p = 0.04; Fig 4A), was higher at night [11, 25, 29] (74.5 ±13.1 vs. 57.8 ±16.6%; MD, 19.16; 95% CI, 13.94 to 24.39%, p <0.001; I2 = 72%, p = 0.03; Fig 4B), and during the day [11, 25, 29] (64.7 ± 10.7 vs. 58.0 ±11.3%; MD, 6.39; 95% CI, 2.11 to 10.67%; p = 0.003; I2 = 60%, p = 0.08; Fig 4C) (Table 2).
HCL = Hybrid Closed Loop Systems; RR = relative risk; CI = confidence interval. A: overall, B: at night, C: during the day.
Sensitivity analysis of TIR. The level of heterogeneity was significantly decreased when sensitivity analyses were performed that removing the study of “Boughton 2022” [9], “Mary B.Abraham 2021” [22] or “R. Paul Wadwa 2023” [29] and the results were stable (S1 Table).
Two studies exceeded the 95% confidence limits in the funnel plot analysis and no significant publication bias was identified based on Begg’s test (p = 602) and Egger’s test (p = 0.133).
Subgroup analysis and meta-regression of TIR. We performed subgroup analyses and meta-regression to identify the potential sources of the heterogeneity. The results showed that age seem to be the source of heterogeneity and the results were stable (S2 and S3 Tables).
Hypoglycemia.
All included studies [8, 9, 11, 14, 22, 24, 25, 28, 29] patients compared the efficacy of the HCL group versus the control group to assess the percentage of time the sensor glucose was in a hypoglycemic range (defined as <70 mg/dL). HCL did not show a beneficial effect on hypoglycemic time <70 mg/dL (3.8 ± 4.5 vs. 4.3 ± 4.9%; MD, −0.22, 95% CI, −0.71 to 0.28%; p = 0.39), and there was evidence of heterogeneity between articles (I2 = 58%, p = 0.02). HCL also did not significantly decrease the overall average percentage of hypoglycemic time <54 mg/dL [9, 11, 14, 22, 24, 25, 28, 29] (0.73 ± 1.34 vs. 0.90 ± 1.40%; MD, −0.07, 95% CI, −0.19 to 0.06%, p = 0.30; I2 = 64%, p = 0.007) (Table 2). HCL systems did not seem to be associated with a lower risk of hypoglycemia [22, 25] (2.2% vs. 0%; OR 5.21, 95% CI, 0.24 to 114.41, p = 0.29) or severe hypoglycemia [8, 9, 11, 14, 22, 24, 25, 28, 29] (2.6% vs. 1.0%; OR 2.18, 95% CI, 0.77 to 6.23, p = 0.14; I2 <0.001%, p = 0.68), and there was no evidence of heterogeneity (Table 3).
Sensitivity analysis of hypoglycemia. Sensitivity analyses using the leave one out method revealed that removing the study of “Boughton 2022” [9] or “Mary B.Abraham 2021” [22] significantly decreased the level of heterogeneity; however, HCL still did not show a beneficial effect on hypoglycemic time <70 and <54 mg/dL (S1 Table).
Subgroup analysis and meta-regression of time of hypoglycemic time <70 mg/dL. We performed subgroup analyses and meta-regression to identify the potential sources of the heterogeneity. The results showed that age, type of trial and therapy duration of HCL did not seem to be the sources of heterogeneity (S2 and S3 Tables).
Hyperglycemia.
The overall percentage of hyperglycemic time was significantly decreased in the HCL group compared to the control group when it was defined as >180 mg/dL [8, 9, 11, 14, 22, 24, 25, 28, 29] (31.9 ± 13.3 vs. 48.3 ± 16.1%; MD, −9.56; 95% CI, −14.17 to −4.95%, p <0.001; I2 = 83%, p <0.001), >250 mg/dL [14, 22, 24, 28, 29] (9.4 ± 7.9 vs. 13.6 ± 9.5%; MD, −6.82; 95% CI, −11.81 to −1.83%; p = 0.007, I2 = 86%, p <0.001) and >300 mg/dL [9, 11, 22, 24, 28, 29] (3.2 ± 3.6 vs. 5.5 ± 6.8%; MD, −2.37; 95% CI, −4.03 to -0.70%, p = 0.005; I2 = 76%, p = 0.001), and there was significant heterogeneity (Table 2).
HCL did not seem to be associated with a lower risk of hyperketosis [8, 14, 24, 25, 28, 29](13.0% vs. 11.3%; OR 1.19, 95% CI, 0.63 to 2.25, p = 0.60), and DKA [8, 9, 14, 22, 24, 25, 28, 29] (0.13% vs. 0%; OR 2.18, 95% CI, 0.43 to 11.00, p = 0.34), and there was no significant heterogeneity (Table 3).
Sensitivity analysis of hyperglycemia. Sensitivity analyses using the leave one out method revealed that the results were stable with respect to hyperglycemic time >180 mg/dL, >250 and >300 mg/dL (S1 Table).
Subgroup analysis and meta-regression of time of hyperglycemic time >180 mg/dL. We performed subgroup analyses and meta-regression to identify the potential sources of the heterogeneity. The results showed that age, type of trial and therapy duration of HCL did not seem to be the sources of heterogeneity (S2 and S3 Tables).
Glucose control and insulin delivery.
The mean glucose level[8, 9, 11, 14, 22, 24, 25, 28, 29] (159.9 ± 28.2 vs. 173.1 ± 30.5 mg/dL; MD, −14.09; 95% CI, −19.48 to -8.70 mg/dL, p <0.001; I2 = 58%, p = 0.01) was significantly decreased by HCL, however, no significant difference was found in the coefficient of variation of sensor glucose[9, 14, 22, 24, 25, 28, 29] (39.5 ± 6.0 vs. 40.3 ± 5.8%; MD, −0.18; 95% CI, −1.72 to 1.36%, p = 0.82; I2 = 71%, p = 0.002) and daily insulin dose [9, 22, 28, 29] (0.90 ± 0.33 vs. 0.91 ± 0.33 U/kg per day; MD, <0.001; 95% CI, −0.05 to 0.06 U/kg per day; p = 0.94; I2 <0.001, p = 0.62) between the HCL group and the control group (Table 2).
Sensitivity analysis of the mean glucose level. The level of heterogeneity was significantly decreased when sensitivity analyses were performed that removing the study of “Boughton 2022” [9] or “Mary B.Abraham 2021” [22] and the results were stable (S1 Table).
Discussion
The pooled results of this meta-analysis showed that HCL exert a beneficial effect on HbA1c management without significant heterogeneity as compared to the standard of care in adolescents and children with T1D when therapy duration of HCL was not less than three months, we should notice that significant heterogeneity was observed in previous meta analyses [33–36]. HCL increased the percentage of time in TIR and decreased hyperglycemic time, which was similar to a recent meta-analysis [26, 27] that better TIR, HbA1c, and less hypoglycemia in HCL in patients with T1D were found. However, the recent important studies [8, 9, 11, 22, 24, 28, 29] were not included in those recent meta-analysis [26, 27], adults were included and the study period was different from 48 h to 6 months.
The management of T1D is further complicated in young individuals, who have unique physiological, behavioral and developmental factors. Young children have higher insulin sensitivity, higher variability in insulin requirements, and more unpredictable eating and activity patterns than adults [36]. HCL have the advantage of delivering insulin in a glucose-responsive manner [37], which is expected to benefit clinical outcomes. Long-term glycemic variability has been reported to be involved in increasing cardiovascular risk, retinopathy and renal failure [38]. In this meta-analysis, HCL showed a beneficial effect on HbA1c management, with a 0.5% decrease compared to the compared to standard of care in adolescents and children with T1D, which was more than the recent study of Boughton with 0.3% decreasing of HbA1c by HCL systems [9]. In a recent pivotal study assessing the HCL over 3 months, the mean HbA1c was improved by 0.7% in children and 0.4% in adults [18]. In a recent 6-month, multicenter, randomized study, HbA1c levels were also significantly decreased and TIR was significantly increased in the HCL group compared to the control group among patients with T1D aged 14–61 years [13]. Compared with the control group, there was a 0.33% reduction in HbA1c levels among the individuals aged 14 to 71 years old using the HCL [13]. Compared to baseline, HbA1c levels improved from 7.3% to 6.8% in the adult group and 7.7% to 7.1% in the adolescent group after 3 months of HCL administration [20].
We only included studies with a duration of more than 3 months, as the HbA1c levels reflect the average blood glucose in 3 months. Previous studies have also shown that glycemic variability and HbA1c levels are reduced in adolescents and adults [20,21] after at least 3 months of HCL administration. Another study even showed that glucose variability was significantly decreased throughout the 24-h day by HCL when compared with baseline [39].
The results of the current meta-analysis were also in agreement with previous meta-analyses [26, 33–35] and many studies [20, 38, 40] that reported that the TIR was significantly increased and the percentage of time in the hyperglycemic range was significantly lower for HCL use than for the standard of care in children and adolescents. The TIR was reported to be increased by approximately 5.7 [40]-12% [34] in the HCL group compared to the standard of care. Our meta-analysis also showed that HCL led to a 11.1% increase in the TIR compared with the standard of care in adolescents and children with T1D over longer periods. A recent meta-analysis showed an 11.73% improvement in TIR based on 25 studies with a total of 504 patients [36]. Another meta-analysis also showed an 11.06% [33] and 9.62% [41] improvement in TIR when comparing HCL to non-closed-loop systems. Not only is TIR generally improved, but TIR during exercise was also improved by 6.18% after HCL administration, especially in children and adolescents [36].
HCL systems did not exert a beneficial effect on hypoglycemic time compared to the standard of care in adolescents and children with T1D, which not consistent with the recent meta-analysis [26]. We should note that the current HCL requires a minimum total daily insulin dose for optimal system performance; however, the total daily dose is usually very low in adolescents and children. This may limit the benefits of closed-loop treatment due to the high variability of such small dose absorption [42]. The variability in blood glucose was higher during the nighttime in young individuals [37], and nocturnal hypoglycemia was expected to be reduced by HCL due to the automation of insulin delivery in response to real-time sensor glucose levels. The beneficial effect of HCL on the nocturnal hypoglycemic time (defined as <70 mg/dL and <54 mg/dL) was also not noted in this meta-analysis. This is also likely related to the ability of HCL to immediately r reduce postprandial hyperglycemia, which is limited by the pharmacodynamics and pharmacokinetics of rapid-acting insulins [43] and even increases the risk of delayed hypoglycemia as a result of increasing algorithm-driven insulin delivery. The rates of hypoglycemia and severe hypoglycemia were not increased by HCL in this meta-analysis. Second, the sensor accuracy of HCL was decreased due to the physiological lag time between blood glucose and interstitial glucose during daytime physical activity, irrespective of the quality of the algorithm [44]. The basal insulin dose has also been found to either decrease [20] or increase [45] during HCL use when compared with controls in some studies. This meta-analysis showed no significant difference in daily insulin dose when HCL was used.
Hyperglycemia was marked in children with type 1 diabetes. One study reported that sensor glucose readings >180 mg/dL even occurred in nearly half of the overnight hours among children with T1D [40]. Parents are always afraid of hypoglycemia and thus might allow hyperglycemia to alleviate worries of dangerous hypoglycemia, especially at night [46]. HCL may reduce parental fears of hypoglycemia at night, which may prevent hyperglycemia-permissive behaviors. Our results showed that HCL led to a greater decrease in time in the hyperglycemia range when it was defined as >180 mg/dL, >250 mg/dL and >300 mg/dL; however, significant heterogeneity remained. However, we found that HCL did not seemed to be associated with a lower risk of hyperketonemia and DKA.
Strengths and limitations
Strengths of this meta-analysis.
For the first time, we included the largest sample (n = 825) and the most rigorous studies as most study designs were randomized trials. HCL studies in adolescents and children have always examined small samples and have had a therapy durations [47]. Second, we performed a comprehensive study to assess the effect of long-term use of HCL on glycemic outcomes in children and adolescents.
Conclusions
HCL had a beneficial effect on HbA1c management and TIR without increased hypoglycemic time as compared to standard of care in adolescents and children with T1D when therapy duration of HCL was not less than three months.
Supporting information
S2 File. The Jadad scale for assessing the methodological quality of clinical trials.
https://doi.org/10.1371/journal.pone.0308202.s002
(DOC)
S1 Fig. Publication bias analysis of HbA1c level.
A: A funnel plot of the risk of HbA1c level. B: Begg’s test; C: Egger’s test.
https://doi.org/10.1371/journal.pone.0308202.s003
(TIF)
S1 Table. Sensitivity analysis for the outcome of HbA1c level, glucose level and percent of sensor glucose values.
HbA1c, Glycated hemoglobin level; MD, mean difference; CI, Confidence interval.
https://doi.org/10.1371/journal.pone.0308202.s004
(DOC)
S2 Table. Subgroup analysis for the outcome of glucose level and percent of sensor glucose values.
HCL, Hybrid Closed Loop Systems.
https://doi.org/10.1371/journal.pone.0308202.s005
(DOC)
S3 Table. Meta-regression for the outcome of glucose level and percent of sensor glucose values.
HCL, Hybrid Closed Loop Systems.
https://doi.org/10.1371/journal.pone.0308202.s006
(DOC)
References
- 1. Zuberi Z, Sauli E, Cun L, et al. Insulin-delivery methods for children and adolescents with type 1 diabetes. Ther Adv Endocrinol Metab. 2020. 11: 2042018820906016. eCollection 2020. pmid:32944212
- 2. Cameron FJ. The Impact of Diabetes on Brain Function in Childhood and Adolescence. Pediatr Clin North Am. 2015. 62(4): 911–27. pmid:26210624
- 3. Jaser Sarah S, Jordan Lori C. Brain Health in Children with Type 1 Diabetes: Risk and Protective Factors. Curr Diab Rep. 2021. Mar 14;21(4):12. pmid:33715053
- 4. Introduction: Standards of Medical Care in Diabetes-2019. Diabetes Care. 2019. 42(Suppl 1): S1–S2. pmid:30559224
- 5. Bachran R, Beyer P, Klinkert C, et al. Basal rates and circadian profiles in continuous subcutaneous insulin infusion (CSII) differ for preschool children, prepubertal children, adolescents and young adults. Pediatr Diabetes. 2012. 13(1): 1–5. pmid:21545675
- 6. Nevo-Shenker M, Phillip M, Nimri R, Shalitin S. Type 1 diabetes mellitus management in young children: implementation of current technologies. Pediatr Res. 2020. 87(4): 624–629. pmid:31715623
- 7. Kariyawasam D, Morin C, Casteels K, et al. Hybrid closed-loop insulin delivery versus sensor-augmented pump therapy in children aged 6–12 years: a randomised, controlled, cross-over, non-inferiority trial. Lancet Digit Health. 2022. 4(3): e158–e168. pmid:35216750
- 8. Ware J, Boughton CK, Allen JM, et al. Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trial. Lancet Digit Health. 2022. 4(4): e245–e255. pmid:35272971
- 9. Boughton CK, Allen JM, Ware J, et al. Closed-Loop Therapy and Preservation of C-Peptide Secretion in Type 1 Diabetes. N Engl J Med. 2022. 387(10): 882–893. pmid:36069870
- 10. Sherr JL, Schoelwer M, Dos Santos TJ, et al. ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery. Pediatr Diabetes. 2022. 23(8): 1406–1431. pmid:36468192
- 11. Ware J, Allen JM, Boughton CK, et al. Randomized Trial of Closed-Loop Control in Very Young Children with Type 1 Diabetes. N Engl J Med. 2022. 386(3): 209–219. pmid:35045227
- 12. Tauschmann M, Thabit H, Bally L, et al. Closed-loop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial. Lancet. 2018. 392(10155): 1321–1329. pmid:30292578
- 13. Brown SA, Kovatchev BP, Raghinaru D, et al. Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes. N Engl J Med. 2019. 381(18): 1707–1717. pmid:31618560
- 14. Breton MD, Kanapka LG, Beck RW, et al. A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes. N Engl J Med. 2020. 383(9): 836–845. pmid:32846062
- 15. Bergenstal RM, Nimri R, Beck RW, et al. A comparison of two hybrid closed-loop systems in adolescents and young adults with type 1 diabetes (FLAIR): a multicentre, randomised, crossover trial. Lancet. 2021. 397(10270): 208–219. pmid:33453783
- 16. Benhamou PY, Franc S, Reznik Y, et al. Closed-loop insulin delivery in adults with type 1 diabetes in real-life conditions: a 12-week multicentre, open-label randomised controlled crossover trial. Lancet Digit Health. 2019. 1(1): e17–e25. pmid:33323237
- 17. Forlenza GP, Ekhlaspour L, DiMeglio LA, et al. Glycemic outcomes of children 2–6 years of age with type 1 diabetes during the pediatric MiniMed™ 670G system trial. Pediatr Diabetes. 2022. 23(3): 324–329. pmid:35001477
- 18. Brown SA, Forlenza GP, Bode BW, et al. Multicenter Trial of a Tubeless, On-Body Automated Insulin Delivery System With Customizable Glycemic Targets in Pediatric and Adult Participants With Type 1 Diabetes. Diabetes Care. 2021. 44(7): 1630–1640. pmid:34099518
- 19. Carlson AL, Sherr JL, Shulman DI, et al. Safety and Glycemic Outcomes During the MiniMed™ Advanced Hybrid Closed-Loop System Pivotal Trial in Adolescents and Adults with Type 1 Diabetes. Diabetes Technol Ther. 2022. 24(3): 178–189. pmid:34694909
- 20. Garg SK, Weinzimer SA, Tamborlane WV, et al. Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes. Diabetes Technol Ther. 2017. 19(3): 155–163. pmid:28134564
- 21. Kovatchev B, Cheng P, Anderson SM, et al. Feasibility of Long-Term Closed-Loop Control: A Multicenter 6-Month Trial of 24/7 Automated Insulin Delivery. Diabetes Technol Ther. 2017. 19(1): 18–24. pmid:27982707
- 22. Abraham MB, de Bock M, Smith GJ, et al. Effect of a Hybrid Closed-Loop System on Glycemic and Psychosocial Outcomes in Children and Adolescents With Type 1 Diabetes: A Randomized Clinical Trial. JAMA Pediatr. 2021. 175(12): 1227–1235. pmid:34633418
- 23. Elleri D, Allen JM, Kumareswaran K, et al. Closed-loop basal insulin delivery over 36 hours in adolescents with type 1 diabetes: randomized clinical trial. Diabetes Care. 2013. 36(4): 838–44. pmid:23193217
- 24. Isganaitis E, Raghinaru D, Ambler-Osborn L, et al. Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial. Diabetes Technol Ther. 2021. 23(5): 342–349. pmid:33216667
- 25. Thabit H, Tauschmann M, Allen JM, et al. Home Use of an Artificial Beta Cell in Type 1 Diabetes. N Engl J Med. 2015. 373(22): 2129–2140. pmid:26379095
- 26. Jiao X, Shen Y, Chen Y. Better TIR, HbA1c, and less hypoglycemia in closed-loop insulin system in patients with type 1 diabetes: a meta-analysis. BMJ Open Diabetes Res Care. 2022 Apr;10(2):e002633. pmid:35450868
- 27. Jabari M. Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis. Sci Rep. 2023. 13(1): 13165. pmid:37574494
- 28. Kanapka LG, Wadwa RP, Breton MD, et al. Extended Use of the Control-IQ Closed-Loop Control System in Children With Type 1 Diabetes. Diabetes Care. 2021. 44(2): 473–478. pmid:33355258
- 29. Wadwa RP, Reed ZW, Buckingham BA, et al. Trial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes. N Engl J Med. 2023. 388(11): 991–1001. pmid:36920756
- 30. No authors listed. Adverse events and their association with treatment regimens in the diabetes control and complications trial. Diabetes Care. 1995. 18(11): 1415–27. pmid:8722064
- 31. Deckert T, Bojsen J, Christiansen JS, Kølendorf K, Svendsen PA, Andersen AR. 24-hour blood glucose profiles in insulin-dependent diabetics treated with intravenous insulin infusion systems. A comparison between closed- and open-loop systems. Acta Med Scand. 1980. 208(6): 451–8. pmid:7008508
- 32. Sterne JA, Sutton AJ, Ioannidis JP, et al. Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ. 2011. 343: d4002. pmid:21784880
- 33. Weisman A, Bai JW, Cardinez M, Kramer CK, Perkins BA. Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials. Lancet Diabetes Endocrinol. 2017. 5(7): 501–512. pmid:28533136
- 34. Karageorgiou V, Papaioannou TG, Bellos I, et al. Effectiveness of artificial pancreas in the non-adult population: A systematic review and network meta-analysis. Metabolism. 2019. 90: 20–30. pmid:30321535
- 35. Kumareswaran K, Elleri D, Allen JM, et al. Meta-analysis of overnight closed-loop randomized studies in children and adults with type 1 diabetes: the Cambridge cohort. J Diabetes Sci Technol. 2011. 5(6): 1352–62. pmid:22226252
- 36. Eckstein ML, Weilguni B, Tauschmann M, et al. Time in Range for Closed-Loop Systems versus Standard of Care during Physical Exercise in People with Type 1 Diabetes: A Systematic Review and Meta-Analysis. J Clin Med. 2021 May 31;10(11):2445. pmid:34072900
- 37. Dovc K, Boughton C, Tauschmann M, et al. Young Children Have Higher Variability of Insulin Requirements: Observations During Hybrid Closed-Loop Insulin Delivery. Diabetes Care. 2019. 42(7): 1344–1347. pmid:31221700
- 38. Forlenza GP, Pinhas-Hamiel O, Liljenquist DR, et al. Safety Evaluation of the MiniMed 670G System in Children 7–13 Years of Age with Type 1 Diabetes. Diabetes Technol Ther. 2019. 21(1): 11–19. pmid:30585770
- 39. Buckingham BA, Forlenza GP, Pinsker JE, et al. Safety and Feasibility of the OmniPod Hybrid Closed-Loop System in Adult, Adolescent, and Pediatric Patients with Type 1 Diabetes Using a Personalized Model Predictive Control Algorithm. Diabetes Technol Ther. 2018. 20(4): 257–262. pmid:29431513
- 40. Sherr JL, Buckingham BA, Forlenza GP, et al. Safety and Performance of the Omnipod Hybrid Closed-Loop System in Adults, Adolescents, and Children with Type 1 Diabetes over 5 Days under Free-Living Conditions. Diabetes Technol Ther. 2020 Mar;22(3):174–184. pmid:31596130
- 41. Bekiari E, Kitsios K, Thabit H, et al. Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis. BMJ. 2018 Apr 18:361:k1310. pmid:29669716
- 42. Ruan Y, Elleri D, Allen JM, et al. Pharmacokinetics of diluted (U20) insulin aspart compared with standard (U100) in children aged 3–6 years with type 1 diabetes during closed-loop insulin delivery: a randomised clinical trial. Diabetologia. 2015 Apr;58(4):687–90. pmid:25537835
- 43. Evans M, Wilkinson M, Giannpolou A. Fast-Acting Insulin Aspart: The Rationale for a New Mealtime Insulin. Diabetes Ther. 2019 Oct;10(5):1793–1800. pmid:31485918
- 44. Zaharieva DP, Turksoy K, McGaugh SM, et al. Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes. Diabetes Technol Ther. 2019 Jun;21(6):313–321. pmid:31059282
- 45. Tauschmann M, Allen JM, Wilinska ME, et al. Home Use of Day-and-Night Hybrid Closed-Loop Insulin Delivery in Suboptimally Controlled Adolescents With Type 1 Diabetes: A 3-Week, Free-Living, Randomized Crossover Trial. Diabetes Care. 2016 Nov;39(11):2019–2025. pmid:27612500
- 46. Van Name MA, Hilliard ME, Boyle CT, et al. Nighttime is the worst time: Parental fear of hypoglycemia in young children with type 1 diabetes. Pediatr Diabetes. 2018 Feb;19(1):114–120. pmid:28429581
- 47. Fuchs J, Hovorka R. Benefits and Challenges of Current Closed-Loop Technologies in Children and Young People With Type 1 Diabetes. Front Pediatr. 2021 Apr 30:9:679484. pmid:33996702