Abstract
This paper proposes an average current mode controller (ACMC) for a single-phase bridgeless power factor correction (PFC) circuit using a single ended primary inductor converter (SEPIC) via second-order model reduction. The superiority of the proposed controller is PFC accomplished at power up to 350 W with high efficiency via the second-order model reduction. The design and implementation of ACMC on the converter operated with continuous conduction mode (CCM) is explained in detail. ACMC forces input current to follow sinusoidal current reference at different power levels and sustain high power factor (PF). The proposed controller is designed based on the theoretical analysis operation of the circuit. For verification, MATLAB/Simulink simulations are carried out and validation through an experiment test rig for 110—220 Vrms input, 100 Vdc/ 350 W output prototype at 20 kHz switching frequency. It is proven that the proposed controller strategy accomplishes high PF, high efficiency and conformity with the simulation.
Citation: Rai NA, Abdul Aziz MJ, Sahid MR, Husain AR, Anjum W, Low WY (2023) Average current mode controller for bridgeless PFC SEPIC converter with second-order model reduction operated in continuous conduction mode. PLoS ONE 18(10): e0291873. https://doi.org/10.1371/journal.pone.0291873
Editor: Chiranjit Sain, Ghani Khan Choudhury Institute of Engineering and Technology, INDIA
Received: February 14, 2023; Accepted: September 7, 2023; Published: October 17, 2023
Copyright: © 2023 Rai et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the paper.
Funding: The authors received no specific funding for this work.
Competing interests: The authors have declared that no competing interests exist.
Introduction
The rapid development of technology using a variety of electronic devices has affected the power quality of the ac system. The losses from these electronic devices have been causing pollution in the electrical system resulting from low power factor (PF). Low power factor causes high peak input current at supply and causes high losses, which provide harmonic distortion to the line system. Hence, power factor correction (PFC) becomes necessary to eradicate losses in all switching power supplies.
PFC sustains a nearly unity power factor by forcing the alternating current input to be in phase with the input voltage. Ac-dc converter normally used bridge rectifier and dc-dc converter to regulate dc output. However, the bridge rectifier contributes to conduction losses to the circuit during operation. Three semiconductor elements are conducted simultaneously, causing an increase of forward voltage drop in the circuit.
The bridgeless converter has been introduced since 1983 by replacing two adjacent diodes in the conventional bridge rectifier with a single switch [1]. This results in eliminating high conduction loss at the input side of the ac-dc converter. The discovery of the converter enhanced to various newer topologies of the bridgeless converter is rolled out with different structures of improvement from the previous bridge converter [2–4]. Numerous studies reported that by eliminating the bridge diode, converter efficiency increases and significantly losses [3–5]. Reduction of cost, high efficiency, weight and maintaining near unity power factor are several advantages of the bridgeless converter. The bridgeless SEPIC converter is one of the eminent converters due to its benefit compared to other dc-dc converters. This converter emits no polarity reversal of output voltage and provides an extensive range of dc output based on the duty cycle. The SEPIC converter is a 4th-order converter; due to having four storage elements in the converter topology, it is not widely investigated due to the controller’s design complexity.
The converter has become a hot topic over the last few decades to overcome traditional bridge SEPIC converter front-end PFC efficiency. Five new bridgeless SEPIC topologies have been introduced with different positioning structures of two active switches and elements, as shown in Fig 1.
In [6], the proposed topology combines two SEPICs in one circuit. The first SEPIC is for the positive input source, while the other is for the negative input source. However, the output ripple of this topology is double that of the conventional SEPIC converter due to existing of the two output capacitors. As illustrated in Fig 1(b), [7] proposed switches replace two diodes of the input bridge rectifier of the conventional SEPIC converter. No additional element is used in this bridgeless SEPIC. Since only one diode is used in the current path during each switching cycle, the circuit has a low conduction loss. This topology gives advantages on the simplicity of design, improved power factor, and semiconductor devices offer low voltage stress.
Low conduction losses are achieved by the proposed bridgeless SEPIC converter in [8], as shown in Fig 1(c). This topology is advantageous concerning the continuous connection between input line voltage and output ground through two slow recovery diodes namely Dp and Dn which is equivalent to the traditional SEPIC. This leads to the elimination of high common-mode EMI noise issued in other bridgeless SEPIC converter, additionally the power switch is driven by similar PWM control which makes it easy to design a control circuit. An additional inductor in the input voltage is designed to improve the thermal performance of the topologies. However, this will contribute to a bulky size converter and simultaneously increase the cost.
The efficiency of the bridgeless PFC SEPIC converter proposed in [9] with reduced voltage stress is shown in Fig 1(d). An auxiliary circuit consisting of a diode and a capacitor is used throughout the topology to decrease the voltage stress on the main switch and diode. Due to the voltage stress of the main switch has been decreased to half, the low voltage element can be used. Hence, the efficiency of the converter is enhanced due to low on-state conduction loss, low Rds(on) in low voltage rating switch and less forward voltage drop in low voltage rating diode. However, the circuit provides a high number of elements with 4 diodes in the circuit design.
The bridgeless SEPIC converter, as proposed in [10], upgraded several drawbacks in [6] whereby the output resistor is not floating, and only one output capacitor is required, as shown in Fig 1(e). As compared to other bridgeless SEPIC converters, the number of elements that conduct during each cycle is minimise which further reduces conduction losses of the bridgeless converter. The bridgeless SEPIC converters act as a simple dc-dc SEPIC converter at each half cycle.
All the above-mentioned bridgeless SEPIC converter topologies are operated in DCM; hence voltage control technique was employed. It is widely known that the bridgeless converter is capable of working in both continuous current mode (CCM) and discontinuous conduction mode (DCM), relying on its implementation. The inductor current is consistently positive for CCM, while for DCM the current returns to zero for each period of time. DCM causes enormous voltage stress in the circuit. Therefore, it gives an impact on electromagnetic interference (EMI) into line [11]. Voltage and current stress in DCM become excessive in high power applications, triggering the converter’s efficiency to deteriorate [12, 13]. Thus, at low power applications, usually less than 300W, DCM is commonly used, while at medium and high applications CCM becomes superior [13–15]. CCM offers lower conduction losses in the semiconductors and inductors, low output voltage ripple, lower conducted noise, lower inductor core loss, and lower inductor core loss even at low power application [13]. Despite the benefits of CCM operation, the design of the CCM controller is more arduous than DCM. Due to the nature of its topologies, DCM can attain a higher power factor as compared to CCM [16, 17]. Therefore, a simple control system is sufficient to achieve PFC.
Meanwhile, intricate control and cascade closed-loop control systems are compulsory in CCM to achieve PFC [16, 18]. In order to reduce the difficulty in controller design, there are numerous methods in reducing the order of the transfer function model reported [19–24]. The controller is optimised by the reduction order and is closely aligned with the step response and the bode plot of the original model. The dynamic response of the reduction model retains the same feature as the original model. It is important to note that most of the bridgeless SEPIC converter studies are operated in DCM with power less than 150W [6–10, 25, 26]. Based on the thorough literature review, only a few papers [27, 28] discusses bridgeless SEPIC converter studied in CCM; however, no verification on the prototype since it only discusses on simulation technique. In [29], the preliminary result of the bridgeless SEPIC converter operated in the CCM prototype is presented. However, the result produces a low power factor and low efficiency.
This paper is an extended work from [29], which describes the design and implementation of average current mode control of bridgeless SEPIC converter with CCM operated at 150 W-350 W via second-order model reduction. The second-order model reduction guarantees the simplicity of tuning the ACMC and acts efficiently as PFC. In general, the paper is organised as follows: Section 2 clarifies the operation mode of the SEPIC PFC converter in CCM. Section 3 and Section 4 discuss the proposed control method used for the converter and identify the converter parameters. In Section 5, the operation of the bridgeless SEPIC converter is validated through simulation results and hardware implementation. Section 6 summarises the main findings in this work.
Operation Mode of SEPIC PFC Converter in CCM
As in [10], the bridgeless SEPIC converter has been inserted with an additional inductor, Lb at the input side. The converter circuit, as shown in Fig 2, is proposed to work in CCM operation with an average current mode controller (ACMC). This converter is chosen due to the simplicity of the structure and fewer elements conduct at each half-cycle compared with other bridgeless SEPIC converters. The circuit consists of two IGBTs, two diodes, three capacitors, and four inductors, apart from a resistor as its load, as shown in Fig 2.
Only nine elements conduct in the positive half cycle, which are La, Lb, S1, Ds2, C1, L2, D1, C3R as shown in Fig 3(a). During the negative half cycle La, Lb, S2, Ds1, C2, L3, D2, C3 and R are conducted as shown in Fig 3(b).
This bridgeless SEPIC converter reduces the number of conduction components through half cycle. At each half cycle of the bridgeless SEPIC converter, it acts as a basic dc-dc SEPIC converter. The previous paper [10], study on bridgeless SEPIC converter operation in DCM with a voltage controller. At each half cycle, DCM operates in three operating modes. The operation of CCM is unlike DCM, whereby for CCM, it only has two modes of operation at each half cycle. The bridgeless SEPIC converter’s operation mode is depicted in Fig 4.
The circuit is working in the same operation for both cycles due to the structure of the circuit, which is symmetrical in both cycles. The arrangement of element and operation is identical except for the reverse polarity of the cycle. Therefore, the converter operation is clarified only for the positive half cycle of the input voltage. The voltage and current operation waveforms of a bridgeless SEPIC converter are shown in Fig 5. To simplify circuit analysis, the sum of inductances, La and Lb is considered to be, L1 = (La + Lb).
In mode 1, S1 and Ds2 turn on by control signal and diode D1 is reversed bias. Inductor L1 charge and inductor current increase linearly concerning the relation of . Capacitor C1, releases the energy to the inductor L2 and generates a current path back to S1. Since, D1 is reversed bias, the output voltage is equivalent to the output capacitor voltage. Based on the operation, the appropriate equations can be specified as follows:
The voltage across the inductor, L1 (1)
The voltage across the inductor, L2 (2)
The current across the series capacitor, C1 (3)
The current across the output capacitor, C3 (4)
In mode 2, S1 turns off and D1 forwards bias, which allows current flow through it. Due to the discharging process through the C1, C3 and load, current across L2 decrease linearly. Based on the operation, the important equations can be specified as follow:
The voltage across the inductor, L1 (5)
The voltage across the inductor, L2 (6)
The current across the series capacitor, C1 (7)
Proposed control method
In order to implement the bridgeless SEPIC converter working in CCM, the basic proportional-integral (PI) controller is used as a compensator in the ACMC. In designing the controller, the transfer function based on a mathematical model is necessary in order to simplify control tuning. The state-space averaging modelling technique [30–32] is employed in the bridgeless SEPIC converter in CCM operation. Applying the KCL and KVL of the bridgeless converter circuit during the turn ON and OFF state of S1 as per Eqs (1)–(8). The average model of the bridgeless SEPIC converter is: (9)
-vector of output system
A- State vector
B-Input matrix
C- Matrix, which connects the output to the state variable
- Input variable (Vin)
- Duty ratio variation for CCM [31]
Based on Eqs 9, 10, and 11, the average matrices for the steady state and linear small signal state space equations of bridgeless SEPIC converters are as follows: - (12) (13) where:
Eqs (12) and (13) are derived based on ac perturbation. The bridgeless SEPIC converter’s transfer function is extracted using the Laplace transformation in (12) and (13). (14) where I4 is a unity matrix, the inner loop and outer loop transfer functions are as follows, based on the expansion and solution of Eq (9): - (15) (16) with:
The design of the controller for a bridgeless SEPIC converter is quite a challenging task since the transfer function is in 4th order. By using model order reduction via improved Padé approximations and Routh Hurwitz array in [19–22], the 4th order transfer function is now reduced to 2nd order to simplify the tuning of the controller:
The 2nd order reduction transfer function is in the form of: - (17)
The original transfer function’s denominator is reduced to 2nd order by using the Routh Hurwitz array. The denominator of the original inner loop transfer function, Gid, is arranged using Eq 15 in the converse Routh array as in Fig 6.
By taking the first three values on the first column of the Routh array, the denominator of the 2nd order transfer function is (18)
By normalising Did, produces (19)
The reduced order of numerator coefficient is attained via improved Padé approximation of the original transfer function, Gid (20) (21) (22) (23) (24) (25)
By substituting Eqs (21–23) into Eqs (24–25) and solving to the 2nd order reduction form in Eq (17), the reduce order transfer function of the inner loop, Rid are: (26) where,
Solving the similar step to the outer loop Gvi transfer function, yield (27) where,
Converter parameters
The proposed circuit is based on the requirements specifications listed in Table 1. The bridgeless SEPIC converter is designed to operate in CCM mode with all parameters.
The boundary between CCM and DCM
All parameters are designed to meet the anticipated performance of the converter based on the following condition: Based on [33, 34], the voltage conversion ratio, (28)
The boundary between CCM and DCM can be determined using the following formula:
Critical conduction parameter, (29)
It is compulsory to choose the conduction parameter, K > Kcrit to guarantee the circuit operates in CCM operation otherwise, it will operate in DCM. In this converter, the K = 0.8 is selected.
Design of inductors
The bridgeless SEPIC converter equivalent inductances are determined as follows:
The equivalent inductor in series, (30) (31) (32)
The inductor L1 values are calculated using the inductor current ripple equation as below (33)
The maximum inductor current ripple is calculated using the permitted ripple of 20% of input current. Value of L3 can be computed based on Eqs (18–20) where R is the load resistance, is the percentage of input current ripple and d is duty ratio (choose the worst case). The value of La = Lb and L2 = L3 because the structures of the converter are symmetrical.
Design of the capacitors
The intermediate capacitor, C1 is designed to adapt the input voltage pattern during the switching cycle and provide constant voltage during the line cycle. In order to avoid input current oscillations at each half cycle, the resonant frequency between (L1, C1, L3, and C3) must be set higher than the line frequency but lower than the switching frequency in order to sustain constant voltage throughout the switching time. (34) where fr is the resonant frequency.
The output capacitor, C3 is used to minimise the output voltage ripple of the converter. It is necessary to be designed large enough to decrease output voltage ripple based on 20% permitted percentage ripple. (35) where ΔVo is the voltage output ripple percentage. Table 2 tabulates the proposed converter parameter for bridgeless SEPIC converter based on the calculation value.
Design of average current mode controller
By substituting the parameter value in Tables 1 and 2 of the bridgeless SEPIC converter in section 4 into Eqs (26) and (27). The step response and bode plot of the bridgeless SEPIC converter for the original model and 2nd order reduction for the inner loop and outer loop as are shown in Figs 7 and 8. The step response of the inner loop reduction model, Rid is identical to the unstable step response found in the original model, Gid as shown in Fig 7(a) while for the outer loop reduction model, Rvi the step response is in good agreement with the original model as witnessed in Fig 8(a).
It can be seen that Rid tracks the unstable condition and inherit all the characteristics of Gid. The inner loop reduction model, Rvi response resembles the original model, Gvi in both steady and transient states. Rid and Rvi transfer function is less complicated, and the complexity during the transfer function tuning process is massively diminished. The bode plot demonstrates that due to the characteristics of Padé approximations, the reduced order, Rid and Rvi are accurate up to 2 kHz and 20 Hz frequency, respectively. These boundary frequencies are important when designing the controller. At high frequencies, the difference in error between the original and reduction model systems is marginal. It is important to note that the Padé approximations provide an excellent job of capturing low frequency dynamics while the accuracy at high frequency increases as the reduction order increases [23]. The step response of both transfer functions inherits the same trait, dynamic response, and exhibits the same behaviors as the original model. The approximation of the converter system in second order is acceptable and most of the system property is preserved. It is simple and effective in simplifying the high-order transfer function controller design.
The proposed controller for the bridgeless SEPIC converter using ACMC is illustrated in Fig 9. ACMC function to force the input current to track the reference current. To reshape the input current, two cascaded loops to perform as a suitable controller are required. The inner loop is designed to control the current and the outer loop to control the voltage. To simplify the proposed controller, Eqs (26) and (27) are used as inner loop and outer loop transfer functions to design the ACMC of the bridgeless SEPIC converter.
The outer loop with a slower response act to provide an error between the reference voltage and the actual output voltage to generate the input current reference for the inner loop. This primary loop function is to adjust and sustain voltage to the desired set point.
The inner loop performs as current shaping for the input current. The actual input current is commanded to track sinusoidal reference current, iref that leads to enhanced input power factor. The current loop compensator adjusts the duty ratio in response to changes in input current, ensuring that the output voltage remains constant. The inner loop output is compared to the sawtooth carrier to produce a pulse width modulation (PWM) signal with a fixed frequency.
The most critical component in attaining the ACMC is the multiplier or multiplication and dividing signal (MDB). MDB role is to accomplish the input current reference signal to feed in the loop. A high power factor can be achieved as the input voltage waveform, and the reference current waveform is identical depending on the multiplier technique [35, 36]. MDB is mainly composed of a PI voltage error, a multiplier, and a division of a rectified voltage input variable |Vin| with an average component of input rectified voltage, Vdc. This controller requires both voltage and current sensors to feed MDB.
The ACMC controller is designed to achieve the preferred PI controller for both the inner and outer loops through the SISO tool in MATLAB/Simulink. The inner loop bandwidth is designed to be a decade lower (2 kHz) than the switching frequency (20 kHz) using the transfer function according to Eq (14) to guarantee the high reliability of the control signal. Hence, the gain for the PI controller for the inner loop is set to Kp = 0.66715 and Ki= 3138, resulting in a phase margin of 76 degrees with bandwidth at 1.2566x104rad/s as can be seen in Fig 10. This value is chosen due to the stability and performance of the controller during the transient response, as well as the ability to achieve the desired bandwidth for the control converter. Both zeros and poles for the transfer function are in the left-hand plane (LHP) which shows the stability of the controller as in Fig 11.
The outer loop bandwidth is assigned to 20 Hz below the line frequency to prevent oscillation in the input current based on the transfer function in the Eq (26). For the outer loop, the gain for the PI controller is set to Kp = 0.37001 and Ki= 17.7822, resulting in a phase margin of 74 degrees with bandwidth at 125.66 rad/s, as shown in Fig 12. Both zeros and poles for the transfer function are in the left-hand plane (LHP) which shows the stability of the controller as in Fig 13. The controller is designed to produce a quick dynamic response and low output voltage ripple.
Simulation and experimental results
The simulation to evaluate the proposed controller was carried out using Matlab/Simulink and the parameters described in Table 2. Fig 14 shows the simulation result at a steady state for 110 Vinrms and 220 Vinrms at the rated load.
It can be seen that the input voltage and the input current are in phase. The output voltage has accomplished the anticipated 100 V while the output current achieves almost 3.5 A for both input voltage. The output voltage and output current ripple for high voltage input generate more ripple than low voltage input based on the simulation outcome. The sinusoidal waveform of the input current for low input voltage shape is less distorted compared to the low voltage input. The average output power successfully achieves 350 W as anticipated. Based on the simulation result, the proposed controller shows a satisfactory result in PFC at CCM operation.
A bridgeless SEPIC converter prototype as shown in Fig 15, is developed to validate the proposed controller and simulation results in CCM. The construction of the prototype setup as per the specifications as in the simulation. The ac input filter has been added in order to maintain a good ac supply to the prototype. The controller is implemented using a basys 3 field-programmable gate array (FPGA) and DS1104 digital signal processing and control engineering (dSPACE) controller board to achieve exact sampling time. The dSPACE control desk is used as an ACMC controller interface to detect input current, input voltage and output voltage as indicated. All the sensing input provides feedback to the dSPACE control desk, and all calculation of MDB calculation is performed to generate a reference current to the converter. However, dSPACE limited the lower sampling time by deferring the prototype performance and consistency from simulation. A low sampling time of 20 μs is achieved by combining dSPACE and basys3 FPGA.
Fig 16 shows the experiment result of the input line voltage and input line current for 110 Vinrms and 220 Vinrms at 350 W. The controller accomplishes to shape the sinusoidal input current as predicted to achieve PFC at CCM operation.
The experimental results support the simulation results whereby the proposed controller able to reshape the input current sinusoidally. To validate the dynamic performance of the controller, the step load change is performed from 150 W to 300W, as shown in Figs 17 and 18. Based on the results, as the step load change, the input current changing but the output voltage is steadily regulated at 100 V.
Fluke 1730 energy logger is used to measure the power factor, total harmonic distortion (THD), input power, and output power of the converter. The power factor is always greater than 0.78 at all load conditions, as shown in Fig 19. At full load, the power factor accomplishes 0.98 at low input voltage (110 Vinrms), while at high input voltage (220 Vinrms), the PF can reach 0.96.
The efficiency of the converter is measured and plotted in Fig 20. Even though the input filter is used at the converter’s front end, the converter’s efficiency still exceeds 78% for all load conditions. As the power increased, the proposed controller attained high efficiency with 91.4% at light load for 110 Vinrmss.
Fig 21 compares the input current THD at a different power level. With the proposed controller, the input current THD significantly improves as the power level increases for both low input voltage and high input voltage. The current input THD measured 6.8% for low input voltage while 9.9% for high input voltage at full load as shown in the fast Fourier transform (FFT) of the input current in Fig 22. It is observed that at medium power, the proposed controller demonstrates that the input current quality is slightly enhanced.
The experiment results have shown that the bridgeless SEPIC performs better at low input voltage, 110 V than at high input voltage, 220 V because it provides low ripple sinusoidal input current, high efficiency, a power factor close to unity, and low THD at all power loads.
Conclusion
This study aims to implement a single-phase PFC bridgeless SEPIC converter operated in CCM using ACMC via second-order reduction. The proposed controller has been analysed theoretically, proven by simulation, and validated through an experimental test rig. The investigation has concluded that the proposed controller with reduction order model shows a good agreement working in CCM operation using ACMC in both simulation and experimental test-rig. The reduction order model ensures simplicity in the controller’s design without affecting the original system’s dynamic response. The observations from this study suggest that a high power factor greater than 0.98 is the archive for all load conditions for low input voltage.
Meanwhile, as the power increased for the high input voltage side, the power factor improved to 0.96. The input current is perfectly reshaped sinusoidally. The converter’s efficiency is 91.46% for low input voltage and 89.65% for high input voltage at light load even though the input filter is used at the front end of the converter. The controller performs steadily at load changing. It can regulate and reshape input current while maintaining PFC at CCM operation at greater than 150 W power. These findings proved that the bridgeless SEPIC converter could operate at a medium power application with 350 W in CCM operation.
References
- 1. Mitchell DM. AC-DC Converter having an improved power factor 1982.
- 2. Huber L, Yungtaek Jang, Jovanovic MM. Performance Evaluation of Bridgeless PFC Boost Rectifiers. IEEE Trans Power Electron 2008;23:1381–90.
- 3. Yang HT, Chiang HW, Chen CY. Implementation of Bridgeless Cuk Power Factor Corrector With Positive Output Voltage. IEEE Trans Ind Appl 2015;51:3325–33.
- 4. Jang Y, Jovanović MM. Bridgeless high-power-factor buck converter. IEEE Trans Power Electron 2011;26:602–11.
- 5.
Singh A, Gupta J, Singh B Bridgeless Modified High-Step-Up Gain SEPIC PFC Converter based Charger for Light EVs Battery IEEE Glob Conf Comput Power Commun Technol GlobConPT 2022.2022;1–6.
- 6. Ismail EH. Bridgeless SEPIC rectifier with unity power factor and reduced conduction losses. IEEE Trans Ind Electron 2009;56:1147–57.
- 7. Mahdavi M, Farzanehfard H. Bridgeless SEPIC PFC rectifier with reduced components and conduction losses. IEEE Trans Ind Electron 2011;58:4153–60.
- 8. Sabzali AJ, Ismail EH, Al-Saffar MA, Fardoun AA. New bridgeless DCM sepic and Cuk PFC rectifiers with low conduction and switching losses. IEEE Trans Ind Appl 2011;47:873–81.
- 9. Lee S-W, Do H-L. Efficient bridgeless PFC converter with reduced voltage stress. Int J Circuit Theory Appl 2016;44:1455–67.
- 10.
Sahid MR, Yatim AHM, Taufik T. A new AC-DC converter using bridgeless SEPIC. IECON Proc (Industrial Electron Conf 2010:286–90.
- 11.
Singh B, Anand A. Power Factor Correction in Modified SEPIC Fed Switched Reluctance Motor Drives. IEEE Trans. Ind. Appl., vol. 54, IEEE; 2018, p.4494–505.
- 12. Sabyasachi S, Mohanty P. Stability Analysis of Sepic Converter Using Matlab / Simulink 2014:27–31.
- 13.
Gegner JP, Lee CQ. Linear Peak Current Mode Control: a Simple Active Power Factor Correction Control Technique for Continuous Conduction Mode. Power Electron Spec Conf 1996 PESC’96 Rec 27th Annu IEEE 1996:196–202.
- 14. Garcia O, Cobos JA, Prieto R, Alou P, Uceda J. Single phase power factor correction: a survey. IEEE Trans Power Electron 2003;18:749–55.
- 15.
Kim JW, Choi SM, Kim KT. Variable On-time Control of the Critical Conduction Mode Boost Power Factor Correction Converter to Improve Zero-crossing Distortion. 2005 Int Conf Power Electron Drives Syst 2005;2:1542–6.
- 16. Rossetto L, Spiazzi G, Tenti P. Control techniques for power factor correction converters. Proc PEMC’94 1994:1–9.
- 17.
Huai Wei, Batarseh I. Comparison of basic converter topologies for power factor correction. Proc. IEEE Southeastcon’98 “Engineering a New Era,” IEEE; 1998, p. 348–53.
- 18. Karaarslan A, Iskender I. Analysis and comparison of current control methods on bridgeless converter to improve power quality. Int J Electr Power Energy Syst 2013;51:1–13.
- 19. Singh V, Chandra D, Kar H. Improved Routh–PadÉ Approximants: A Computer-Aided Approach. IEEE Trans Automat Contr 2004;49:292–6.
- 20.
Singh R, Mishra VM, Singh J. Model Order Reduction via Routh Hurwitz Array and Improved Pade Approximations. 2018 Int. Conf. Power Energy, Environ. Intell. Control, IEEE; 2018, p. 755–8.
- 21. Pal J. Stable reduced-order Pade approximants using the Routh-Hurwitz array. Electron Lett 1979;15:225.
- 22. Shamash Y. Stable reduced-order models using Padé-type approximations. IEEE Trans Automat Contr 1974;19:615–6.
- 23. Hutton M. and Friedland B., Routh approximations for reducing order of linear, time-invariant systems, IEEE Trans. Automat. Contr., vol. 20, no. 3, pp. 329–337, Jun. 1975.
- 24. Hsieh C-S, Hwang C. Model reduction of continuous-time systems using a modified Routh approximation method. IEE Proc D Control Theory Appl 1989;136:151.
- 25. Krishnamurthy V, Seshadri V. Model reduction using the Routh stability criterion. IEEE Trans Automat Contr 1978;23:729–31.
- 26.
Jumadril JN, Ponniran A, Noor MKR, Rashid MAZA, Kasiran AN, Yatim MH An Improved Two-Switch Bridgeless PFC SEPIC Structure for Total Harmonic Distortion Reduction and Circulating Current Minimization. ICECOS 2019—3rd Int Conf Electr Eng Comput Sci Proceeding. 2019;277–82.
- 27.
Ewerling MVM, Font CHI. Single-stage AC/DC converter based on sepic topology operating in continuous conduction mode. 2017 Brazilian Power Electron. Conf., IEEE; 2017, p. 1–6.
- 28.
Patel US, Shiva Kumar S, Kommukuri VS Power Factor Correction using Continuous Conduction Mode based Bridgeless SEPIC Converter for Improved THD and Voltage Regulation. Proc—Int Conf Vis Towar Emerg Trends Commun Networking, ViTECoN 2019. 2019;1–4.
- 29. Rai NA, Junaidi M, Aziz A, Sahid MR, Sahid MR. Bridgeless PFC single ended primary inductance converter in continuous current mode ijpeds.v10.i3.1427-1436, 2019;10.
- 30.
Eng V, Pinsopon U, Bunlaksananusorn C. Modeling of a SEPIC converter operating in continuous conduction mode. 2009 6th Int Conf Electr Eng Comput Telecommun Inf Technol ECTI-CON 2009 2009;1:136–9.
- 31.
Kanaan HY, Al-Haddad K. Small-signal averaged model and carrier-based linear control of a SEPIC-type power factor correction circuit. INTELEC, Int Telecommun Energy Conf 2008.
- 32. Middlebrook R, ĆUK S. A general unified approach to modelling switching-converter power stages. Int J Electron 1977;42:521–50.
- 33. Sebastian J, Lopera JM, Cobos JA, Uceda J. The Determination of the Boundaries Between Continuous and Discontinuous Conduction Modes in PWM DC-to-DC Converters Used as Power Factor Preregulators. IEEE Trans Power Electron 1995;10:574–82.
- 34. Spiazzi G, Mattavelli P. Design criteria for power factor preregulators based on Sepic and Cuk converters in continuous conduction mode. Proc 1994 IEEE Ind Appl Soc Annu Meet n.d.:1084–9.
- 35. Dixon L. Average current mode control of switching power supplies. Unitrode Power Supply Des Semin Man SEM700 1990:1–12.
- 36. Zhang Y, Xu W, Yu Y. The PFC with average current-mode and voltage fuzzy controller for the output voltage. Proc—2008 2nd Int Symp Intell Inf Technol Appl IITA 2008 2008;1:771–5.