Duty cycle of 33% increases cardiac output during cardiopulmonary resuscitation

  • Taegyun Kim,

    Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Software, Validation, Visualization, Writing – original draft, Writing – review & editing

    Affiliation Department of Emergency Medicine, Seoul National University Hospital, Seoul, Republic of Korea

  • Kyung Su Kim ,

    Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Supervision, Validation, Writing – review & editing

    kanesu@gmail.com

    Affiliation Department of Emergency Medicine, Seoul National University Hospital, Seoul, Republic of Korea

  • Gil Joon Suh,

    Roles Conceptualization, Funding acquisition, Investigation, Methodology, Project administration, Writing – review & editing

    Affiliations Department of Emergency Medicine, Seoul National University Hospital, Seoul, Republic of Korea, Department of Emergency Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea

  • Woon Yong Kwon,

    Roles Conceptualization, Investigation, Methodology, Resources, Writing – review & editing

    Affiliations Department of Emergency Medicine, Seoul National University Hospital, Seoul, Republic of Korea, Department of Emergency Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea

  • Yoon Sun Jung,

    Roles Conceptualization, Funding acquisition, Investigation, Writing – review & editing

    Affiliation Division of Critical Care Medicine, Seoul National University Hospital, Seoul, Republic of Korea

  • Jung-In Ko,

    Roles Conceptualization, Investigation, Writing – review & editing

    Affiliations Department of Emergency Medicine, National Medical Center, Jung-gu, Seoul, Republic of Korea, Department of Emergency Medicine, College of Medicine, Kangwon National University, Chuncheon-si, Gangwon-do, Republic of Korea

  • So Mi Shin

    Roles Conceptualization, Investigation, Writing – review & editing

    Affiliation Department of Emergency Medicine, Seoul National University Hospital, Seoul, Republic of Korea

Abstract

Background

The aim of this study was to investigate whether 33% duty cycle increases end-tidal carbon dioxide (ETCO2) level, a surrogate measurement for cardiac output during cardiopulmonary resuscitation (CPR), compared with 50% duty cycle.

Methods

Six pigs were randomly assigned to the DC33 or DC50 group. After 3 min of induced ventricular fibrillation (VF), CPR was performed for 5 min with 33% duty cycle (DC33 group) or with 50% duty cycle (DC50 group) (phase I). Defibrillation was delivered until return of spontaneous circulation (ROSC) thereafter. After 30 min of stabilization, the animals were re-assigned to the opposite groups. VF was induced again, and CPR was performed (phase II). The primary outcome was ETCO2 during CPR, and the secondary outcomes were coronary perfusion pressure (CPP), systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and right atrial pressure (RAP).

Results

Mean ETCO2 was higher in the DC33 group compared with the DC50 group (22.5 mmHg vs 21.5 mmHg, P = 0.018). In a linear mixed model, 33% duty cycle increased ETCO2 by 1.0 mmHg compared with 50% duty cycle (P < 0.001). ETCO2 increased over time in the DC33 group [0.6 mmHg/min] while ETCO2 decreased in the DC50 group [-0.6 mmHg/min] (P < 0.001). Duty cycle of 33% increased SAP (6.0 mmHg, P < 0.001), DAP (8.9 mmHg, P < 0.001) RAP (2.6 mmHg, P < 0.001) and CPP (4.7 mmHg, P < 0.001) compared with the duty cycle of 50%.

Conclusion

Duty cycle of 33% increased ETCO2, a surrogate measurement for cardiac output during CPR, compared with duty cycle of 50%. Moreover, ETCO2 increased over time during CPR with 33% duty cycle while ETCO2 decreased with 50% duty cycle.

Introduction

High-quality cardiopulmonary resuscitation (CPR) is essential for the survival of cardiac arrest victims [1]. Chest compression is a key component of high-quality CPR [2]. Duty cycle is defined as the fraction of chest compression time in an entire chest compression cycle. Although 50% duty cycle is recommended during CPR according to the current guidelines [3, 4], shorter duty cycle that allows increased cardiac filling and cardiac output may be beneficial [57]. Duty cycle cannot be modulated during manual chest compressions. However, mechanical compression devices are widely used recently [8, 9], and mechanical compression devices can be modulated to provide chest compression with duty cycle other than 50%.

Pigs are used in various animal researches including sepsis, haemorrhage and cardiac arrest [1013]. They are especially suitable as experimental animals for cardiac arrest, for they have large chest to accommodate forceful chest compressions and external defibrillations. Moreover, attaching monitoring devices including intravascular catheter is relatively easier in pigs as they are large mammals, and physiologic parameters of pigs and humans are very similar [14].

Our hypothesis was that shorter duty cycle might provide sufficient time for cardiac filling and might result in increased cardiac output during CPR. We performed this study to investigate whether shorter duty cycle is associated with higher end-tidal carbon dioxide (ETCO2) in a swine cardiac arrest model, an index value that positively correlates with cardiac output during CPR [15].

Materials and methods

Study setting

This study was a prospective crossover animal experiment. Male domestic pigs weighing 37–43.5 kg were used for the experiment because of their wide use in CPR experiments. All experimental procedures were approved by the Institutional Animal Care and Use Committee of Seoul National University Hospital (IACUC No. 17-0186-S1A2).

Animal preparation

The experimental animals were purchased for the experiment via the animal laboratory office of Seoul National University Hospital. The experimental animals underwent acclimatisation periods of 14 days before the experiments. The animals were fed with laboratory chow twice a day and were checked by a veterinarian every day. The breeding room temperature was maintained from 18 to 29°C. All the experiments were conducted during daytime at an animal laboratory. Under supine position, the animals were induced for anaesthesia with an intramuscular injection of 5 mg/kg of Zoletil (zolazepam and tiletamin; Virbac Korea, Republic of Korea) and intubated with 6.5 F cuffed endotracheal tubes for mechanical ventilation. Initially, a tidal volume of 10 mL/kg and a frequency of 15/min were applied and adjusted to keep the ETCO2 level within 35–45 mmHg. Anaesthesia was maintained with inhalation of 1%–1.5% of isoflurane and nitrous oxide. An Arrow Seldinger Arterial Catheter (20 Gauge; Teleflex Inc., USA) and an IntroFlex introducer (8.5 Fr; Edwards Lifesciences Corporation, USA) were inserted into the right common carotid artery and the right external jugular vein with cutdown techniques, respectively. A Swan-Ganz catheter (7.5 Fr; Edwards Lifesciences Corporation, USA) was placed in the right atrium through the introducer. Vecaron Injection (vecuronium; Reyon Pharmaceutical. Co. LTD., Republic of Korea) was continuously infused at a rate of 10 mg/h throughout the experiments. The experiments were performed following haemorrhagic shock and autotransfusion experiments with 145 min-long protocol, and 30 minutes of stabilisation periods were allowed between the two experiments. The animals were under mechanical ventilation throughout the haemorrhagic shock and autotransfusion experiments and the main experiments. We predetermined the humane endpoint for euthanasia as follows: when the systolic blood pressure is below 60 mmHg, or the heart rate is below 50 beats per minute. Animals were planned to be euthanatized with intravenous bolus injection of 40 mEq of potassium chloride if they met the humane endpoint.

Experimental protocol (Fig 1)

The animals were alternatively assigned to the 33% duty cycle (DC33) group or the 50% duty cycle (DC50) group. A pacing catheter was inserted into the right ventricle, and direct current was delivered with a 9 V battery for 5 s to induce ventricular fibrillation. CPR was started after 3 min of no-flow time. Chest compression was provided using a robot manipulator (VM-6083G model, Denso Co., Ltd., Japan) [16, 17] with a constant rate of 100/min and a constant depth of 5 cm, but with different duty cycles according to the assigned group (phase I). Mechanical ventilation was delivered with a rate of 10/min and a tidal volume of 10 mL/kg during CPR. After 5 min of CPR, 1 mg of epinephrine was injected intravenously, and external defibrillations (biphasic, 200 J) were delivered using a Zoll R Series Defibrillator (Zoll Medical, USA) every min until ROSC. The animals were stabilised for another 30 min after ROSC, they were assigned to the opposite groups, and the same experiments were conducted (phase II).

thumbnail
Fig 1. Study timeline for the animals initially assigned to the DC33 or DC50 group.

Defibrillation was delivered every minute until ROSC was achieved. VF, ventricular fibrillation; CPR, cardiopulmonary resuscitation; ROSC, return of spontaneous circulation; DC33, 33% duty cycle; DC50, 50% duty cycle.

https://doi.org/10.1371/journal.pone.0228111.g001

Data collection and outcome measures

We collected the following parameters throughout the experiments: body weight, systolic arterial pressure (SAP), diastolic arterial pressure (DAP), right atrial pressure (RAP), heart rate, arterial oxygen saturation and ETCO2. All data were acquired every 2 s using a Vital Recorder program during CPR [18]. The maximal ETCO2 values during every 6 s (i.e. three measurements) were selected because of ventilation rate during CPR. Coronary perfusion pressure (CPP) was defined as the difference between DAP and RAP. The primary outcome was ETCO2 during CPR, and the secondary outcomes were CPP, SAP, DAP and RAP.

Statistical analysis

Continuous variables were presented as means ± standard errors or values (95% confidence intervals) and compared using Student`s t-tests. We used linear mixed models to test the association among variables including duty cycle, time and outcome variables during CPR. Two-sided P values below 0.05 were considered as statistically significant. All analyses were performed using R version 3.5.1 (R Foundation).

Results

No animal was euthanatized during the experiments, and all animals finished the whole experimental protocol. Baseline parameters are described in Table 1. Mean ETCO2 during CPR was higher in the DC33 group compared with the DC50 group (22.5 ± 0.3 mmHg vs. 21.5 ± 0.3 mmHg, P = 0.02).

thumbnail
Table 1. Baseline haemodynamic parameters at the beginning of the experiments.

https://doi.org/10.1371/journal.pone.0228111.t001

In a linear mixed model, 33% duty cycle affected ETCO2 significantly (P < 0.001), increasing ETCO2 in the DC33 group by 1.0 ± 0.3 mmHg compared with DC50 (Fig 2). The interaction between ETCO2 and time was significant (P < 0.001). ETCO2 increased over time in the DC33 group [0.6 (0.4–0.8) mmHg/min], whereas it decreased in the DC50 group [-0.6 (-0.9–-0.4) mmHg/min].

thumbnail
Fig 2. Mean ETCO2 by group over time.

ETCO2, end-tidal carbon dioxide; DC33, 33% duty cycle; DC50, 50% duty cycle.

https://doi.org/10.1371/journal.pone.0228111.g002

Duty cycle of 33% increased SAP (6.0 ± 0.7 mmHg, P < 0.001), DAP (8.9 ± 0.3 mmHg, P < 0.001) RAP (2.6 ± 0.3 mmHg, P < 0.001) and CPP (4.7 ± 0.4 mmHg, P < 0.001) compared with the duty cycle of 50%. The interactions were significant between SAP and time [1.9 (1.0–2.7) mmHg/min vs. -0.8 (-1.3–-0.3) mmHg/min, P < 0.001), between DAP and time [0.5 (-0.2–1.2) mmHg/min vs. -0.8 (-1.6–-0.1) mmHg, P < 0.001), between RAP and time [0.2 (-0.4–0.8) mmHg/min vs. 0.7 (0.1–1.2) mmHg, P = 0.02) and between CPP and time [1.0 (0.3–1.6) mmHg/min vs. -1.2 (-1.8–-0.5) mmHg/min, P < 0.001] (Fig 3).

thumbnail
Fig 3.

(A) mean systolic arterial pressure, (B) mean diastolic arterial pressure, (C) mean right atrial pressure* and (D) mean coronary perfusion pressure* by group over time. *Right atrial pressure and coronary perfusion pressure were missing in two animals of DC33 group (pig 1 and pig 2) and in three animals of DC50 group (pig 1, pig 2 and pig 3). DC33, 33% duty cycle; DC50, 50% duty cycle.

https://doi.org/10.1371/journal.pone.0228111.g003

Discussion

In the present study, 33% duty cycle resulted in higher ETCO2, SAP, DAP, RAP and CPP compared with the 50% duty cycle during CPR. Moreover, 33% duty cycle increased the above values except RAP over time, whereas 50% duty cycle decreased the parameters. Higher ETCO2 value represents better systemic circulation [15] and higher CPP is associated with more ROSC [19], and these results suggest that 33% duty cycle may be more appropriate than 50% duty cycle during CPR.

Shorter duty cycle allows enough time for cardiac filling, which leads to higher cardiac output during CPR [57]. The results from the present study support the previous studies reporting the association between shorter duty cycle and better haemodynamic parameters during CPR. With widespread use of mechanical CPR and implication of robot CPR in clinical fields in the future, our finding can be considered to modulate the default duty cycle of the above devices.

Although not always consistent, there are several reports on the association between duty cycle and haemodynamic parameters during CPR. Dean et al. [20] have reported that CPR with 30% duty cycle improved myocardial and cerebral perfusion. However, their experimental animals were too young, rather closer to paediatric population, and the compression rates and depths were not constant among the comparison groups. On the contrary, another animal experiment showed no association between reduced duty cycle and coronary perfusion pressure [21], with the limitations that the compression rate was 80/min and decompression depth was 2 cm using an active compression-decompression-CPR device, which might have attenuated the effects of shorter duty cycle during relaxation. Lampe et al. [22] recently reported on the changes in haemodynamic parameters including aortic blood flow, aortic pressure and CPP during CPR according to compression waveforms with different compression rate and different duty cycle, but they have not concluded which waveform is optimal. The compression rate in the study ranged from 50/min to 150/min, and these values are beyond the recommendation from the guidelines [3, 4].

One of the strengths of the current study is that the experiments were conducted according to the current guidelines on adult CPR [3, 4]. We performed this experimental study with fixed compression rate (100/min) and depth (5 cm); therefore, we could also minimize the confounding effects of compression rate, compression depth and compression quality variability according to rescuer fatigue. Finally, we have used the robot manipulator, which provided enough power and precision to carry out the experiments.

Our study has several limitations. First, this was an animal experiment using pigs that once underwent a haemorrhagic shock experiment. The animals might have taken various degrees of ischemic injury during haemorrhagic shock. The design of the preceding experiment was basically a haemorrhagic shock and autotransfusion model, and there is a chance that the pigs were not fully recovered from systemic ischemia-reperfusion injury at the time of the beginning of the duty cycle experiments. We tried to minimize the individual effect from the preceding experiments, and the crossover design might have attenuated the individual differences according to the preceding experiments. Second, we could not measure the rate of ROSC or neurological outcomes because of the design of the study. Moreover, we could not measure cardiac output during the experiments despite insertion of Swan-Ganz catheters. We had to measure RAP continuously, hence we could not locate the tips of the catheters at pulmonary arteries during CPR. We measured ETCO2 and CPP instead, which are the known surrogate markers for cardiac output and ROSC, respectively [15, 19]. Finally, the relatively round shape of the pig chest compared with the humans might have altered the effectiveness of chest compression using the robot manipulator. However, the pigs are used in CPR experiments widely according to their large chests allowing forceful precordial chest compressions [14]. We also tried to maintain consistency in chest compression by tying up the pigs on the experimental table with the ropes and holding the pigs during chest compression. In a previous swine CPR experimental study, the robot manipulator showed stable and effective chest compression even with the alteration in the compression points [17].

We tried to comply with the replacement, refinement and reduction (the 3Rs) principle during the whole experimental process. The pigs were inevitably used for the experiments as our study outcome measures were not able to be investigated with in vitro experiments or simulation studies. We performed the duty cycle experiments in succession to the haemorrhagic shock-autotransfusion experiments, instead terminating the animals to minimise unnecessary sacrifices. The pigs were provided with inhaled anaesthesia to reduce pain.

Conclusions

In conclusion, duty cycle of 33% increased ETCO2, a surrogate measurement for cardiac output during CPR, compared with the duty cycle of 50%. Moreover, ETCO2 increased over time with 33% duty cycle, whereas ETCO2 decreased with 50% duty cycle.

Supporting information

S1 File. The Animal Research: Reporting of In Vivo Experiments (ARRIVE) guidelines checklist.

https://doi.org/10.1371/journal.pone.0228111.s001

(PDF)

S2 File. The dataset which was used for the analysis.

https://doi.org/10.1371/journal.pone.0228111.s002

(CSV)

References

  1. 1. Kronick SL, Kurz MC, Lin S, Edelson DP, Berg RA, Billi JE, et al. Part 4: Systems of Care and Continuous Quality Improvement: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2015;132(18 Suppl 2):S397–413. Epub 2015/10/17. pmid:26472992
  2. 2. Meaney PA, Bobrow BJ, Mancini ME, Christenson J, de Caen AR, Bhanji F, et al. Cardiopulmonary resuscitation quality: [corrected] improving cardiac resuscitation outcomes both inside and outside the hospital: a consensus statement from the American Heart Association. Circulation. 2013;128(4):417–35. Epub 2013/06/27. pmid:23801105
  3. 3. Kleinman ME, Brennan EE, Goldberger ZD, Swor RA, Terry M, Bobrow BJ, et al. Part 5: Adult Basic Life Support and Cardiopulmonary Resuscitation Quality: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2015;132(18 Suppl 2):S414–35. Epub 2015/10/17. pmid:26472993
  4. 4. Perkins GD, Handley AJ, Koster RW, Castren M, Smyth MA, Olasveengen T, et al. European Resuscitation Council Guidelines for Resuscitation 2015: Section 2. Adult basic life support and automated external defibrillation. Resuscitation. 2015;95:81–99. Epub 2015/10/20. pmid:26477420
  5. 5. Niles DE, Sutton RM, Nadkarni VM, Glatz A, Zuercher M, Maltese MR, et al. Prevalence and hemodynamic effects of leaning during CPR. Resuscitation. 2011;82 Suppl 2:S23–6. Epub 2012/01/03. pmid:22208173
  6. 6. Yannopoulos D, McKnite S, Aufderheide TP, Sigurdsson G, Pirrallo RG, Benditt D, et al. Effects of incomplete chest wall decompression during cardiopulmonary resuscitation on coronary and cerebral perfusion pressures in a porcine model of cardiac arrest. Resuscitation. 2005;64(3):363–72. Epub 2005/03/01. pmid:15733767
  7. 7. Zuercher M, Hilwig RW, Ranger-Moore J, Nysaether J, Nadkarni VM, Berg MD, et al. Leaning during chest compressions impairs cardiac output and left ventricular myocardial blood flow in piglet cardiac arrest. Crit Care Med. 2010;38(4):1141–6. Epub 2010/01/19. pmid:20081529
  8. 8. Perkins GD, Lall R, Quinn T, Deakin CD, Cooke MW, Horton J, et al. Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial. Lancet. 2015;385(9972):947–55. Epub 2014/12/04. pmid:25467566
  9. 9. Rubertsson S, Lindgren E, Smekal D, Ostlund O, Silfverstolpe J, Lichtveld RA, et al. Mechanical chest compressions and simultaneous defibrillation vs conventional cardiopulmonary resuscitation in out-of-hospital cardiac arrest: the LINC randomized trial. JAMA. 2014;311(1):53–61. Epub 2013/11/19. pmid:24240611
  10. 10. Hartmann C, Loconte M, Antonucci E, Holzhauser M, Holle T, Katzsch D, et al. Effects of Hyperoxia During Resuscitation From Hemorrhagic Shock in Swine With Preexisting Coronary Artery Disease. Crit Care Med. 2017;45(12):e1270–e9. Epub 2017/10/14. pmid:29028763
  11. 11. von Seth M, Lipcsey M, Engstrom P, Larsson A, Hillered L, Maripuu E, et al. Rapid Bolus Administration Does not Increase The Extravasation Rate of Albumin: A Randomized Controlled Trial in The Endotoxemic Pig. Shock. 2017;47(4):514–9. Epub 2016/10/18. pmid:27749758
  12. 12. Chalkias A, Spyropoulos V, Koutsovasilis A, Papalois A, Kouskouni E, Xanthos T. Cardiopulmonary Arrest and Resuscitation in Severe Sepsis and Septic Shock: A Research Model. Shock. 2015;43(3):285–91. Epub 2014/11/14. pmid:25394247
  13. 13. Wang S, Wu JY, Guo ZJ, Li CS. Effect of rescue breathing during cardiopulmonary resuscitation on lung function after restoration of spontaneous circulation in a porcine model of prolonged cardiac arrest. Crit Care Med. 2013;41(1):102–10. Epub 2012/12/28. pmid:23269128
  14. 14. Cherry BH, Nguyen AQ, Hollrah RA, Olivencia-Yurvati AH, Mallet RT. Modeling cardiac arrest and resuscitation in the domestic pig. World J Crit Care Med. 2015;4(1):1–12. Epub 2015/02/17. pmid:25685718
  15. 15. Shibutani K, Muraoka M, Shirasaki S, Kubal K, Sanchala VT, Gupte P. Do changes in end-tidal PCO2 quantitatively reflect changes in cardiac output? Anesth Analg. 1994;79(5):829–33. Epub 1994/11/01. pmid:7978395
  16. 16. Jung J, Kim J, Kim S, Kwon WY, Na SH, Kim KS, et al. Application of Robot Manipulator for Cardiopulmonary Resuscitation. In: Kulić D, Nakamura Y, Khatib O, Venture G, editors. 2016 International Symposium on Experimental Robotics. Springer, Cham; 2017. pp. 266–274. https://doi.org/10.1007/978-3-319-50115-4
  17. 17. Suh GJ, Park J, Lee JC, Na SH, Kwon WY, Kim KS, et al. End-tidal CO2-guided automated robot CPR system in the pig. Preliminary communication. Resuscitation. 2018;127:119–24. Epub 2018/04/18. pmid:29665427
  18. 18. Lee HC, Jung CW. Vital Recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices. Sci Rep. 2018;8(1):1527. Epub 2018/01/26. pmid:29367620
  19. 19. Paradis NA, Martin GB, Rivers EP, Goetting MG, Appleton TJ, Feingold M, et al. Coronary perfusion pressure and the return of spontaneous circulation in human cardiopulmonary resuscitation. JAMA. 1990;263(8):1106–13. Epub 1990/02/23. pmid:2386557
  20. 20. Dean JM, Koehler RC, Schleien CL, Atchison D, Gervais H, Berkowitz I, et al. Improved blood flow during prolonged cardiopulmonary resuscitation with 30% duty cycle in infant pigs. Circulation. 1991;84(2):896–904. Epub 1991/08/01. pmid:1860231
  21. 21. Sunde K, Wik L, Naess PA, Ilebekk A, Nicolaysen G, Steen PA. Effect of different compression—decompression cycles on haemodynamics during ACD-CPR in pigs. Resuscitation. 1998;36(2):123–31. Epub 1998/05/08. pmid:9571728
  22. 22. Lampe JW, Yin T, Bratinov G, Kaufman CL, Berg RA, Venema A, et al. Effect of compression waveform and resuscitation duration on blood flow and pressure in swine: One waveform does not optimally serve. Resuscitation. 2018;131:55–62. Epub 2018/08/10. pmid:30092277