Figures
Abstract
Wearable sensors have potential for quantitative, gait-based, point-of-care fall risk assessment that can be easily and quickly implemented in clinical-care and older-adult living environments. This investigation generated models for wearable-sensor based fall-risk classification in older adults and identified the optimal sensor type, location, combination, and modelling method; for walking with and without a cognitive load task. A convenience sample of 100 older individuals (75.5 ± 6.7 years; 76 non-fallers, 24 fallers based on 6 month retrospective fall occurrence) walked 7.62 m under single-task and dual-task conditions while wearing pressure-sensing insoles and tri-axial accelerometers at the head, pelvis, and left and right shanks. Participants also completed the Activities-specific Balance Confidence scale, Community Health Activities Model Program for Seniors questionnaire, six minute walk test, and ranked their fear of falling. Fall risk classification models were assessed for all sensor combinations and three model types: multi-layer perceptron neural network, naïve Bayesian, and support vector machine. The best performing model was a multi-layer perceptron neural network with input parameters from pressure-sensing insoles and head, pelvis, and left shank accelerometers (accuracy = 84%, F1 score = 0.600, MCC score = 0.521). Head sensor-based models had the best performance of the single-sensor models for single-task gait assessment. Single-task gait assessment models outperformed models based on dual-task walking or clinical assessment data. Support vector machines and neural networks were the best modelling technique for fall risk classification. Fall risk classification models developed for point-of-care environments should be developed using support vector machines and neural networks, with a multi-sensor single-task gait assessment.
Citation: Howcroft J, Lemaire ED, Kofman J (2016) Wearable-Sensor-Based Classification Models of Faller Status in Older Adults. PLoS ONE 11(4): e0153240. https://doi.org/10.1371/journal.pone.0153240
Editor: Zhong-Ke Gao, Tianjin University, CHINA
Received: August 19, 2015; Accepted: March 27, 2016; Published: April 7, 2016
Copyright: © 2016 Howcroft et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are available from the Scholars Portal Dataverse network (http://hdl.handle.net/10864/11530).
Funding: This work was supported by the Natural Sciences and Engineering Research Council of Canada (NSERC); the Ontario Ministry of Training, Colleges and Universities; and the University of Waterloo.
Competing interests: The authors have declared that no competing interests exist.
Introduction
Falls are a serious health concern for the elderly, with 30% of individuals older than 65 years falling each year [1], costing approximately 20 billion dollars a year in the United States [2]. Approximately half of these falls occur during walking activities [3]. After experiencing a fall, fear of falling can reduce activities of daily living, leading to physical deterioration, social isolation, and decreased quality of life [1,4].
Predicting fall risk would allow earlier interventions for fall risk reduction [5]. Wearable sensors have potential for quantitative, gait-based, point-of-care fall risk assessment that can be easily and quickly implemented in clinical-care and older-adult living environments. A wide variety of wearable-sensor, inertial-based variables have been used to predict and classify fall risk with varying levels of success (accuracy: 62–100%, specificity: 35–100%, sensitivity: 55–99%) [6]. A detailed review of fall-risk assessment using inertial sensors is given in Howcroft [6]. Gait data is a cyclic, time-series set (i.e., repeated steps). Network techniques have been used in other healthcare applications with time-series data sets; such as, pathological heartbeat detection [7], ventricular fibrillation detection [8], and detection of pathological brain dynamics [9–11]. Broader, non-health care applications include turbulence [12], flow [13,14], and chaotic [15] dynamics analysis.
While wearable-sensor-based fall risk prediction and classification have had some success, optimized prediction and classification models that consider sensor type (e.g. accelerometer, gyroscope, pressure-sensing insole), sensor placement (e.g. head, pelvis, sternum, ankles, shoes), and model type (e.g. neural network, naïve Bayesian, decision tree, support vector machine, logistic regression) [6] are required. Some studies compared sensor-based fall risk predictive and classification capabilities to clinical questionnaire and assessment-based fall risk predictive and classification capabilities [16–19] and most found that adding wearable sensor data to the model improved fall risk prediction and classification compared to models based only on clinical data [16–18]. However, no study has compared model performance using different sensor types, sensor body locations, or combinations of sensors. Furthermore, few studies [20–22] have assessed different model types to optimize fall risk classification and predictive capabilities.
This paper presents a comprehensive investigation of fall-risk classification capabilities that included two types of wearable sensors (accelerometers, pressure-sensing insoles), four accelerometer locations (head, pelvis, left and right shank), and three types of models (neural network, support vector machine, naive Bayesian). Furthermore, the effect of cognitive demand on fall risk classification was assessed using single-task (ST) and dual-task (DT) gait. The objectives of this study were to: (1) identify the best wearable-sensor type, location, and combination for faller status classification (faller or non-faller), (2) determine whether single-task or dual-task gait is more effective for faller status classification, and (3) determine if models based on wearable-sensor gait measurement outperform models based on clinical assessment for older-adult faller classification.
Methods
Participants
A convenience sample of 100 people, 65 years or older, were recruited from the community (Table 1). Participants were identified as fallers if they reported at least one fall during the six months prior to study participation. Potential participants were excluded if they had a cognitive disorder (self-reported) or were unable to walk for six minutes without an assistive device. The University of Waterloo, Office of Research Ethics approved the study and all participants gave informed written consent.
Protocol
Participants reported six month retrospective fall occurrence, age, and sex. Body weight and height were measured. Participants completed the Activities-specific Balance Confidence (ABC) scale [23] and Community Health Activities Model Program for Seniors (CHAMPS) [24] questionnaires. They also ranked their fear of falling from 0 (no fear) to 10 (high level of fear).
Pressure-sensing insoles (F-Scan 3000E, Tekscan, Boston, MA) were equilibrated using multi-point calibration (137.9, 275.8, 413.7 kPa), fit to the shoes, and calibrated. Accelerometers (X16-1C, Gulf Coast Data Concepts, Waveland, MS) were attached to the posterior head with a band, posterior pelvis with a belt, and lateral shank, just above the ankle, with a band. Plantar pressure data were collected at 120 Hz and accelerometer data at 50 Hz.
In separate trials, the time to complete a 7.62 m (25 ft) walk with (dual task: DT) and without (single task: ST) a cognitive load was recorded. The cognitive load was a verbal word fluency task requiring the participants to say words starting with A, F, or S [25]. Participants also completed the six minute walk test (6MWT) under standard, ST conditions [26]. The starting letter and order of walking activities were randomized.
Data Processing
Gait velocities for ST and DT trials were calculated as 7.62 m divided by the time. Plantar-pressure and accelerometer data were exported to Matlab v2010a to calculate outcome variables for the 7.62 m ST and DT trials. Thirty plantar-pressure derived parameters were:
- Center of Pressure (CoP) path (Fig 1): Since the CoP path should advance monotonically and anteriorly, posterior CoP path movements were identified as irregular. The number, length, and duration of posterior deviations (PD) per stance phase were determined. Similarly, smooth medial and lateral movements were expected. Deviations were defined as the first derivative of the CoP ML signal exceeding a dual threshold of ± 0.5 mm/frame [27]. The number, length, and duration of ML path deviations per stance were determined. Minimum, maximum, mean, and median CoP path velocities were also calculated and normalized by stance time. AP and ML coefficients of variation (CoV) for the stance phase CoP path were calculated by determining the mean and standard deviation of CoP path positions at 1% intervals, determined using ensemble averaging [28], for the entire stance phase and calculating the overall CoP path stance phase CoV as in Winter [29].
- Temporal: Cadence, stride time, stance time, swing time, percent stance time, percent double support time, stride time symmetry index [30] between the left and right limbs, and CoV for stride time, stance time, and swing time.
- Impulse: Impulse variables were determined from the total force-time curve (sum of forces from all insole sensels, Fig 2) and calculated based on the area under the force-time curve normalized by body mass (Ns/kg) for: I1 (foot-strike to first peak), I2 (first peak to minimum), I3 (minimum to second peak), I4 (second peak to foot-off), I5 (foot-strike to minimum), I6 (minimum to foot-off), and I7 (foot-strike to foot-off).
All variables were calculated for each stride for the left and right limbs for each walking condition (ST and DT) before calculating means and standard deviations across both limbs (i.e. left and right limb combined).
For accelerometer data (Fig 3), the positive vertical axis was upwards, positive AP axis was anterior, and positive ML axis was toward the participant’s right. Accelerometer-derived parameters were:
- Descriptive statistics: Maximum, mean, and standard deviation of acceleration for the superior, inferior, anterior, posterior, right, and left axes.
- Temporal features: Cadence and stride time.
- Fast Fourier Transform (FFT) Quartile: Percentage of acceleration frequencies in the first quartile (i.e., frequencies ≤ 12.5 Hz) of an FFT frequency plot for vertical, AP, and ML axes.
- Ratio of even to odd harmonics (REOH): Proportion of the acceleration signal in phase with stride frequency. The harmonic ratio is used to measure irregular accelerations and overall gait pattern stability [31–33]. The harmonic ratio was calculated for vertical, AP, and ML axes as in Smidt [34].
- Maximum Lyapunov exponent (MLE): Average rate of expansion or contraction of the original trajectory in response to perturbations [35,36], calculated for vertical, AP, and ML accelerations, as in van Schooten [37]. The number of dimensions was determined using the global false nearest neighbours method [38] and a fixed time delay based on the first minimum of the average mutual information [39].
Vertical: positive is upwards, AP: positive is anterior, ML: positive is toward participant’s right.
For descriptive statistics and MLE parameters, acceleration data were filtered using a fifth order, low pass Butterworth filter with a 12.5 Hz cut-off frequency. Unfiltered acceleration data were used to calculate the FFT quartile and REOH.
Model Development
Three classifier models were assessed for fall-risk classification capability: multi-layer perceptron neural network (NN), naïve Bayesian (NB), and support vector machine (SVM). Retrospective fall occurrence was the classification criterion. For all models, 75% of participant data (18 fallers, 57 non-fallers) were used for training and 25% were used for testing (6 fallers, 19 non-fallers). Pelvis accelerometer data were missing for two non-fallers and left shank accelerometer data were missing for one non-faller due to sensor power failure. All models were developed with the Matlab R2010a standard model algorithms. The Neural Network Pattern Recognition Toolbox was used for NN development and supervised backpropagation training was performed using the Neural Network Training tool. NN with 5, 10, 15, 20, and 25 nodes in a single hidden layer were evaluated. Neural networks between the best NN and the best of the two neighbouring NN were also evaluated. For example, if the 15-node NN provided the best classification and the 20-node NN outperformed the 10-node NN, NN with 16, 17, 18, and 19 nodes were also evaluated. Other models included linear and quadratic multinomial NB models, and SVM with polynomial kernels with degrees one to seven.
Fall classification models were based on all gait variables derived from the wearable sensors, separately for ST and DT gait data. All possible sensor combinations (Table 2) were evaluated using all 138 parameters (30 pressure insole parameters, 29 accelerometer parameters at 4 body locations). In addition, models were developed with clinical assessment data: ABC score, CHAMPS derived activity frequency and calorie expenditure, 6MWT distance, ST and DT walk times, fear of falling levels.
Model evaluation parameters included accuracy, specificity, sensitivity, positive predictive value (PPV), negative predictive value [40], F1 score (harmonic mean of precision and sensitivity) [41], and Matthew’s Correlation Coefficient (MCC) [42]. F1 score was calculated as: (1) and MCC was calculated as: (2) where TP = true positive, TN = true negative, FP = false positive, and FN = false negative. A ranking method similar to Kendell [43] was used to determine the best models. Each model evaluation parameter was ranked from best (1) to worst (n), and ranks for all model evaluation parameters were summed to identify the overall best model (lowest summed rank) (Fig 4). For comparative purposes, classifying all participants as non-fallers would produce an accuracy of 76%, sensitivity of 0%, specificity of 100%, PPV of 0%, NPV of 76%, F1 score of 0, and MCC of 0.
ClinAssess: Clinical assessment measures, NB: Naive Bayesian, NN: Neural network, SVM: Support vector machine.
Results
Of the best 50 fall-risk classifier models based on ST data (Table 3), the top four models (I-P SVM, I-H-P SVM, I-P NN, I-H-P-LS NN) had identical top ranking scores with an accuracy of 84%, F1 0.600, and MCC 0.521. These models classified participants using support vector machines (degree 2 and 3) and neural networks (9 and 20 nodes) and included combinations of 30 pressure insole variables, 29 head accelerometer variables, 29 pelvis accelerometer variables, and 29 left shank accelerometer variables. The fifth best model (H SVM), based on 29 head accelerometer variables, achieved an overall accuracy of 84% and the highest scores for F1 (0.667) and MCC (0.561) but relatively low specificity and PPV prevented this model from ranking higher. The head sensor-based models ranked the highest of the single-sensor models with two models ranking in the top six. No other single-sensor models ranked among the top 10. All 50 models achieved an MCC > 0, indicating that their performance was better than chance. The five models based solely on clinical assessment data ranked the lowest.
Of the best 50 fall-risk classifier models based on DT data (Table 4), the top model (I-P SVM) achieved an overall accuracy of 80%, F1 score of 0.706, and MCC of 0.634. This model classified participants using a support vector machine (degree of 1) and included 30 pressure insole variables and 29 pelvis accelerometer variables. The second best model, which was based solely on pelvis accelerometer data, achieved an overall accuracy of 80%, the second highest F1 score (0.545) and second highest MCC (0.421). This model classified participants using a neural network (7 nodes) and 29 pelvis accelerometer variables. All 50 models achieved an MCC > 0, indicating that their performance was better than chance. The pelvis sensor-based models ranked the highest of the single-sensor models, with three models ranking in the top ten. The next best single-sensor model was LS NN, with one model among the top 10. In contrast to the ST data, two of the models based solely on clinical assessment data ranked twelfth (identical scores).
A comparison between the ten best ST and ten best DT models (Table 5) shows that all but one of the ST models outranked and thus clearly outperformed the DT models.
Discussion
Models derived from this investigation predicted retrospective fall occurrence with varying degrees of accuracy, sensitivity, and specificity. The large number of models assessed using different combinations of sensor-based-measures, model types, and ST or DT gait data permitted determination of the optimal combination for fall risk classification.
The head and pelvis accelerometers provided the best single-sensor classification capability, with two head sensor-based models ranking among the top six for ST and three pelvis sensor-based models among the top ten for DT. In previous studies, the pelvis or lower back location was the most frequent sensor site for fall risk prediction and classification models [6]. This location is intuitively appropriate since it is close to the body center of mass. The pelvis location also allows unobtrusive and easy monitoring with a belt attached sensor or accelerometer-equipped smartphone, and high user acceptance was found for a 20 day case-study with a lower back sensor [44]. The head location may have provided strong single-sensor results because it provided measurements relevant to visual input and upper body stability. While the head accelerometer performed well for ST gait assessment, the pelvis accelerometer performed better for DT gait assessment. The pelvis accelerometer appears in nine of the top ten DT models and seven of the top ten ST models, whereas the head accelerometer appears in one of the top ten DT models and six of the top ten ST models. The head accelerometer may not perform as well under DT conditions when the head may experience non-gait related movements during attention demanding periods (e.g., struggling to think of another word that starts with the desired letter, researcher prompts to continue with cognitive task). The pelvis location is less likely to experience non-gait related movements under DT conditions. Our study is the first to directly compare sensor locations (head, pelvis, left shank, right shank) to show that an accelerometer located at the head and posterior pelvis are superior for single-sensor-based fall risk classification.
While a single sensor is practical, the best results were found with multiple sensors, particularly when combining pelvis and head accelerometer with pressure-sensing insole parameters. The top ST models (I-P, I-H-P, I-P, I-H-P-LS) achieved an accuracy of 84%, F1 score of 0.600, MCC of 0.521, sensitivity of 50%, and specificity of 95% using the pressure-sensing insole and head, pelvis, and left shank accelerometers. The best single-sensor head-based model also achieved an accuracy of 84%, F1 score of 0.667, MCC of 0.561, sensitivity of 67%, and specificity of 90%. Therefore, the multi-sensor models were better at classifying non-fallers and the head-based model was better at classifying fallers. While the multi-sensor models ranked first in the ST ranking analysis (Table 3), the head-based model ranked first when comparing ST and DT models (Table 5), with all these models having similar SR scores. Therefore, both the multi-sensor and single-sensor models achieved strong fall risk classification performance and represent a trade-off between model sensitivity and specificity. The benefit of using insole and accelerometer sensor types, as well as multiple sensor locations, may outweigh the additional cost and complexity in implementing multiple sensors for point-of-care assessments. However, the head sensor accurately identified retrospective fall occurrence and should be considered if a lower cost and faster to implement assessment is desired.
ST models outperformed DT models in overall ranking of performance measures, thus demonstrating better fall risk classification by ST models. While DT gait can reveal increased fall risk from impaired executive functioning that impacts mobility control [45–48], fall risk has a broad spectrum of physical, psychological, social, and environmental risk factors [49]. DT gait data could improve classification ability for those with impaired executive functioning, but worsen classification ability for those with normal executive functioning. Furthermore, other studies have failed to find an improvement in fall prediction and classification under DT gait conditions, compared to ST, in older individuals [50,51]. For people at risk of falling but with normal executive functioning, normal gait deterioration due to a second cognitive task may mask gait-related fall risk factors, thus worsening fall risk classification performance.
The sensor based models were also compared to models developed from commonly performed clinical point-of-care assessments. ST sensor based models outperformed clinical assessment based models, with clinical assessment models ranking lowest of the 50 ranked models. These results demonstrate the advantage of using wearable sensors when assessing fall risk compared to using only common clinical assessments. This is supported by Weiss [16], van Schooten [17], and Rispens [18] who found that sensor-based classifier and predictive models, or a combination of sensor and clinical assessment, improved fall risk classification and prediction compared to clinical assessment alone.
Three different intelligent modeling techniques were assessed in this study: neural networks, naive Bayesian classifiers, and support vector machines. The top ten models, based on ST gait data, used six support vector machines, three multi-layer perceptron neural networks, and one naive Bayesian classifier (10th). Support vector machines and NN provided the best classification of retrospective fall occurrence when trained with ST gait-based data.
This study used retrospective fall occurrence as the criterion for classifying faller and non-faller status. While this is superior to using a clinical assessment based criterion [6], future studies should use prospective fall occurrence as the criterion for classification. Retrospective fall occurrence has two main limitations: inaccurate recall of falls and changes to gait patterns that occur between the fall and assessment, either in an attempt to increase stability or as a result of fear of falling. Future studies should use prospective fall occurrence. Future studies could include readily available participant information, such as age and sex, to determine if adding these parameters to the wearable sensor-based models improves performance.
In this study, computation time was considered acceptable since the run-time for trained models were typically less than 0.04 s for all models. The small computation time could provide outcome results to a clinician immediately after data collection. For applications that require computation times in the order of several ms, neural networks should be considered with caution since neural networks typically have longer computational time compared to support vector machines and naive Bayesian classifiers, given the greater complexity of neural networks [52].
Conclusions
Wearable-sensor based models were able to predict retrospective fall occurrence in older individuals and outperform the predictive ability of models based on clinical assessments. Multi-sensor gait assessment provided the best input data for fall risk classification, using the foot-pressure-sensing insole and head, pelvis, and left shank accelerometers. Fall risk single-task gait assessment using a single-sensor would be best with the head sensor. Single-task gait assessment was better that dual-task for evaluating multi-factorial fall risk of older adults. Support vector machines and neural networks were the best intelligent modelling technique for fall risk classification. Fall risk classification models developed for point-of-care environments should be developed using support vector machines and neural networks, with a multi-sensor single-task gait assessment.
Acknowledgments
The authors thank Deep Shah for assistance with data collection, United Church of Canada and the University of Waterloo Retirees Association for assistance with recruitment, and Chartwell Bankside Terrace Retirement Residence for assistance with recruitment and providing space for data collection at their facility.
Author Contributions
Conceived and designed the experiments: JH EL JK. Performed the experiments: JH EL JK. Analyzed the data: JH. Contributed reagents/materials/analysis tools: EL JK. Wrote the paper: JH EL JK.
References
- 1. Masud T, Morris RO. Epidemiology of falls. Age Ageing. 2001; 30:3–7.
- 2. Stevens JA, Corso PS, Finkelstein EA, Miller TR. The costs of fatal and nonfatal falls among older adults. Injury Prevent. 2006; 12:290–5.
- 3. Ashley MJ, Gryfe CI, Annies A. A longitudinal study of falls in an elderly population. II. Some circumstances of falling. Age Ageing. 1977; 6:211–20. pmid:596308
- 4. Lee RYW, Carlisle AJ. Detection of falls using accelerometers and mobile phone technology. Age Ageing. 2011; 40:690–6. pmid:21596711
- 5. Rao SS. Prevention of falls in older patients. American Family Physician. 2005; 72:81–8. pmid:16035686
- 6. Howcroft J, Kofman J, Lemaire ED. Review of fall risk assessment in geriatric populations using inertial sensors. J Neuroeng Rehabil. 2013; 10:91. pmid:23927446
- 7. Hou FZ, Wang J, Wu XC, Yan FR. A dynamic marker of very short-term heartbeat under pathological states via network analysis. EPL. 2014; 107:58001.
- 8. Li X, Dong Z. Detection and prediction of the onset of human ventricular fibrillation: An approach based on complex network theory. Phys Rev E. 2011; 84:062901.
- 9. Lehnertz K, Ansmann G, Bialonski S, Dickten H, Geier C, Porz S. Evolving networks in the human epileptic brain. Physica D. 2014; 267:7–15.
- 10. Siggiridou E, Kugiumtzis D, Kimiskidis VK. Correlation networks for identifying changes in brain connectivity during epileptiform discharges and transcranial magnetic stimulation. Sensors. 2014; 14:12585–97. pmid:25025550
- 11. Zanin M, Sousa P, Papo D, Bajo R, Garcia-Prieto J, del Pozo F, et al. Optimizing functional network representation of multivariate time series. Sci Rep. 2012; 2:630. pmid:22953051
- 12. Liu C, Zhou WX, Yuan WK. Statistical properties of visibility graph of energy dissipation rates in three-dimensional fully developed turbulence. Physica A. 2010; 389:2675–81.
- 13. Gao ZK, Yang YX, Fang PC, Zou Y, Xia CY, Du M. Multiscale complex network for analyzing experimental multivariate time series. EPL. 2015; 109:30005.
- 14. Gao ZK, Fang PC, Ding MS, Jin ND. Multivariate weighted complex network analysis for characterizing nonlinear dynamic behavior in two-phase flow. Exp Therm Fluid Sci. 2015; 60:157–64.
- 15. Gao ZK, Jin ND. A directed weighted complex network for characterizing chaotic dynamics from time series. Nonlinear Anal Real World Appl. 2012; 13:947–52.
- 16. Weiss A, Brozgol M, Dorfman M, Herman T, Shema S, Giladi N, et al. Does the evaluation of gait quality during daily life provide insight into fall risk? A novel approach using 3-day accelerometer recordings. Neurorehabil Neural Repair. 2013; 27:742–52. pmid:23774124
- 17. van Schooten KS, Pijnappels M, Rispens SM, Elders PJM, Lips P, van Dieen JH. Ambulatory fall-risk assessment: Amount and quality of daily-life gait predict falls in older adults. J Gerontol Med Sci. 2015; 70:608–15.
- 18. Rispens SM, van Schooten KS, Pijnappels M, Daffertshofer A, Beek PJ, van Dieen JH. Do extreme values of daily-life gait characteristics provide more information about fall risk than median values? JMIR Res Prtoc. 2015; 4:e4.
- 19. Greene BR, Doheny EP, Kenny RA, Caulfield B. Classification of frailty and falls history using a combination of sensor-based mobility assessments. Physiol Meas. 2014; 35:2053–66. pmid:25237821
- 20. Caby B, Kieffer S, de Saint Hubert M, Cremer G, Macq B. Feature extraction and selection for objective gait analysis and fall risk assessment by accelerometry. BioMedical Engineering OnLine. 2011; 10:1. pmid:21244718
- 21. Marschollek M, Rehwald A, Wolf KH, Gietzelt M, Nemitz G, Meyer zu Schwabedissen H, et al. Sensor-based fall risk assessment—an expert 'to go'. Methods Inf Med. 2011; 50:420–6. pmid:21206963
- 22. Kojima M, Obuchi S, Henmi O, Ikeda N. Comparison of smoothness during gait between community dwelling elderly fallers and non-fallers using power spectrum entropy of acceleration time-series. J Phys Ther Sci. 2008; 20:243–8.
- 23. Powell LE, Myers AM. The Activities-Specific Balance Confidence (ABC) scale. J Gerontol Med Sci. 1995; 50A:M28–34.
- 24. Stewart AL, Mills KM, King AC, Haskell WL, Gillis D, Ritter PL. CHAMPS physical activity questionnaire for older adults: Outcomes for interventions. Med Sci Sports Exerc. 2001; 33:1126–41. pmid:11445760
- 25. Rende B, Ramsberger G, Miyake A. Commonalities and differences in the working memory components underlying letter and category fluency tasks: A dual-task investigation. Neuropsychology 2002; 16:309–21. pmid:12146678
- 26. Guyatt GH, Sullivan MJ, Thompson PJ, Fallen EL, Pugsley SO, Taylor DW, et al. The 6-minute walk: a new measure of exercise capacity in patients with chronic heart failure. Can Med Assoc J. 1985; 132:919–23. pmid:3978515
- 27. Biswas A, Lemaire ED, Kofman J. Dynamic gait stability index based on plantar pressures and fuzzy logic. J Biomech. 2008; 41:1574–81. pmid:18395211
- 28. Egret CI, Vincent O, Weber J, Dujardin FH, Chollet D. Analysis of 3D kinematics concerning three different clubs in golf swing. Int J Sports Med. 2003; 24:465–70. pmid:12905097
- 29.
Winter DA. The Biomechanics and Motor Control of Human Gait: Normal, Elderly and Pathological. 2nd ed. Waterloo, Ontario: University of Waterloo Press; 1991.
- 30. Sadeghi H, Allard P, Prince F, Labelle H. Symmetry and limb dominance in able-bodied gait: A review. Gait Posture. 2000; 12:34–45. pmid:10996295
- 31. Latt MD, Menz HB, Fung VS, Lord SR. Acceleration patterns of the head and pelvis during gait in older people with Parkinson’s disease: A comparison of fallers and nonfallers. J Gerontol Med Sci. 2009; 64A:700–6.
- 32. Menz HB, Lord SR, Fitzpatrick RC. Acceleration patterns of the head and pelvis when walking are associated with risk of falling in community-dwelling older people. J Gerontol Med Sci. 2003; 58A: 446–52.
- 33. Yack HJ, Berger RC. Dynamic stability in the elderly: Identifying a possible measure. J Gerontol Med Sci. 1993; 48: M225–30.
- 34. Smidt GL, Arora JS, Johnston RC. Accelerographic analysis of several types of walking. Am J Phys Med. 1971; 50:285–300. pmid:5141651
- 35. Liu J, Lockhart TE, Jones M, Martin T. Local dynamic stability assessment of motion impaired elderly using electronic textile pants. IEEE Trans Autom Sci Eng. 2008; 5:696–702. pmid:20953265
- 36. Toebes MJP, Hoozemans MJM, Furrer R, Dekker J, van Dieen JH. Local dynamic stability and variability of gait are associated with fall history in elderly subjects. Gait Posture. 2012; 36:527–31. pmid:22748312
- 37. van Schooten KS, Rispens SM, Pijnappels M, Daffertshofer A, van Dieen JH. Assessing gait stability: The influence of state space reconstruction on inter- and intra-day reliability of local dynamic stability during over-ground walking. J Biomech. 2013; 46:137–41. pmid:23159098
- 38. Kennel MB, Brown R, Abarbanel HDI. Determining embedding dimension for phase-space reconstruction using a geometrical construction. Phys Rev A. 1992; 45:3403–11. pmid:9907388
- 39. Fraser AM, Swinney HL. Independent coordinates for strange attractors from mutual information. Phys Rev A. 1986; 33:1134–40.
- 40. Lalkhen AG, McCluskey A. Clinical tests: Sensitivity and specificity. Continuing Education in Anaesthesia, Critical Care and Pain. 2008; 8(6):221–3.
- 41.
van Rijsbergen CJ. Information Retrieval. Butterworths, London, 1979.
- 42. Matthews BW. Comparison of the predicted and observed secondary structure of T4 phage lysozyme. Biochim Biophys Acta. 1975; 405:442–51. pmid:1180967
- 43. Kendell C, Lemaire ED, Losier Y, Wilson A, Chan A, Hudgins B. A novel approach to surface electromyography: An exploratory study of electrode-pair selection based on signal characteristics. Journal of NeuroEngineering and Rehabilitation. 2012; 9:24. pmid:22537650
- 44. Giansanti D, Morelli S, Maccioni G, Constantini G. Toward the design of a wearable system for fall-risk detection in telerehabilitation. Telemed e-Health. 2009; 15:296–9.
- 45. Ijmker T, Lamoth CJC. Gait and cognition: The relationship between gait stability and variability with executive function in persons with and without dementia. Gait Posture. 2012; 35:126–30. pmid:21964053
- 46. Lamoth CJ, van Deudekom FJ, van Campen JP, Appels BA, de Vries OJ, Pijnappels M. Gait stability and variability measures show effects of impaired cognition and dual tasking in frail people. J Neuroeng Rehabil. 2011; 8:2. pmid:21241487
- 47. Hausdorff JM, Schweiger A, Herman T, Yogev-Seligmann G, Giladi N. Dual-task decrements in gait: Contributing factors among healthy older adults. J Gerontol A Biol Sci Med Sci. 2008; 63A:1335–43.
- 48. Montero-Odasso M, Oteng-Amoako A, Speechley M, Gopaul K, Beauchet O, Annweiler C, et al. The motor signature of mild cognitive impairment: Results from the gait and brain study. J Gerontol A Biol Sci Med Sci. 2014; 69:1415–21. pmid:25182601
- 49. Martin FC. Falls risk factors: Assessment and management to prevent falls and fractures. Canadian Journal on Aging. 2011; 30:33–44. pmid:24650637
- 50. Beauchet O, Allali G, Annweiler C, Berrut G, Maarouf N, Herrmann FR, et al. Does change in gait while counting backward predict the occurrence of a first fall in older adults? Gerontology. 2008; 54:217–23. pmid:18408360
- 51. Bootsma-van der Wiel A, Gussekloo J, de Craen AJM, van Exel E, Bloem BR, Westendorp RGJ. Walking and talking as predictors of falls in the general population: The Leiden 85-plus study. J Am Geriatr Soc. 2003; 51:1466–71. pmid:14511170
- 52. Hens AB, Tiwari MK. Computational time reduction for credit scoring: An integrated approach based on support vector machine and stratified sampling method. Expert Syst Appl. 2012; 39: 6774–81.