Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Assessment of Double Outlet Right Ventricle Associated with Multiple Malformations in Pediatric Patients Using Retrospective ECG-Gated Dual-Source Computed Tomography

  • Ke Shi,

    Affiliation Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China

  • Zhi-gang Yang ,

    Contributed equally to this work with: Zhi-gang Yang, Ying-kun Guo

    yangzg666@163.com (ZGY); gykpanda@163.com (YKG)

    Affiliations Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China, National Key Laboratory of Biotherapy, West China Hospital, Sichuan University, 17# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China

  • Jing Chen,

    Affiliation Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China

  • Ge Zhang,

    Affiliation Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China

  • Hua-yan Xu,

    Affiliations Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041, China, National Key Laboratory of Biotherapy, West China Hospital, Sichuan University, 17# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China

  • Ying-kun Guo

    Contributed equally to this work with: Zhi-gang Yang, Ying-kun Guo

    yangzg666@163.com (ZGY); gykpanda@163.com (YKG)

    Affiliation Department of Radiology, West China Second University Hospital, Sichuan University, 20# Section 3 South Renmin Road, Chengdu, Sichuan 610041, China

Abstract

Purpose

To evaluate the feasibility and diagnostic accuracy of retrospective electrocardiographically (ECG)-gated dual-source computed tomography (DSCT) for the assessment of double outlet right ventricle (DORV) and associated multiple malformations in pediatric patients.

Materials and Methods

Forty-seven patients <10 years of age with DORV underwent retrospective ECG-gated DSCT. The location of the ventricular septal defect (VSD), alignment of the two great arteries, and associated malformations were assessed. The feasibility of retrospective ECG-gated DSCT in pediatric patients was assessed, the image quality of DSCT and the agreement of the diagnosis of associated malformations between DSCT and transthoracic echocardiography (TTE) were evaluated, the diagnostic accuracies of DSCT and TTE were referred to surgical results, and the effective doses were calculated.

Results

Apart from DORV, 109 associated malformations were confirmed postoperatively. There was excellent agreement (κ = 0.90) for the diagnosis of associated malformations between DSCT and TTE. However, DSCT was superior to TTE in demonstrating paracardiac anomalies (sensitivity, coronary artery anomalies: 100% vs. 80.00%, anomalies of great vessels: 100% vs. 88.57%, separate thoracic and abdominal anomalies: 100% vs. 76.92%, respectively). Combined with TTE, DSCT can achieve excellent diagnostic performance in intracardiac anomalies (sensitivity, 91.30% vs. 100%). The mean image quality score was 3.70 ± 0.46 (κ = 0.76). The estimated mean effective dose was < 1 mSv (0.88 ± 0.34 mSv).

Conclusions

Retrospective ECG-gated DSCT is a better diagnostic tool than TTE for pediatric patients with complex congenital heart disease such as DORV. Combined with TTE, it may reduce or even obviate the use of invasive cardiac catheterization, and thus expose the patients to a much lower radiation dose.

Introduction

Double outlet right ventricle (DORV) is a complex congenital heart disease that occurs via embryological ventriculoarterial discordance such that the two great arteries completely or predominately arise (>50%) from the right ventricle [1]. Digital subtraction angiography is considered to be the gold standard initial imaging modality for application in cases of pediatric patients with DORV. However, it is an invasive procedure that carries risks associated with catheter-related complications. Another inevitable issue is its high radiation dose [2]. For the last decade, transthoracic echocardiography (TTE) has been regarded as the first-line imaging modality for pediatric patients with DORV. However, the small acoustic window and operator dependence are inherent disadvantages that affect its diagnostic performance. In addition, magnetic resonance imaging is a promising imaging modality because of its radiation-free nature. Nevertheless, some pediatric patients, particularly those with claustrophobia, are not suited for this examination because of the long acquisition time. Moreover, the need for high spatial resolution and elimination of motion artifacts to achieve optimal diagnostic image quality remains a current challenge [3].

Electrocardiographically (ECG)-gated dual-source computed tomography (DSCT) with high temporal resolution, low radiation doses, and excellent image quality has evolved into a reliable tool for pediatric patients with congenital heart diseases such as DORV [4]. Currently, the use of prospective ECG-gated scanning mode is preferred in pediatric patients with regular and low heart rhythm [5]. However, most pediatric patients have the relatively high or irregular heart rhythm, for these patients, it cannot achieve satisfactory image quality, particularly of intracardiac structures and coronary arteries [6]. However, the retrospective ECG-gated scanning mode, which allows a retrospective selection of the optimal instant for image reconstruction, can provide improved image quality for these patients [5, 7, 8]. To date, few studies have focused on the assessment of retrospective ECG-gated DSCT in pediatric patients who suffer from DORV. Thus, the purpose of this study was to evaluate the feasibility and diagnostic accuracy of retrospective ECG-gated DSCT for DORV and associated multiple malformations in pediatric patients.

Materials and Methods

Ethics statement

For its retrospective characteristic of this study, a application for exemption of patients’ informed consents was approved by the Institutional Review Board (IRB), and we pledged to abide by the declaration of Helsinki (2000 EDITION) in accordance with the relevant medical research rules of China in the study. In addition, no intervention was given in participations with strict secrecy for personal information and privacy. IRB at West China Hospital of Sichuan University approved this study.

Study population

A total of 56 patients with DORV who were referred to our hospital between January 2010 and July 2014 were enrolled. The study inclusion criteria were patients <10 years of age and preoperative DSCT and TTE examination. The exclusion criteria were nonsurgical patients and unstable clinical conditions (n = 9). Finally, 47 patients remained (26 males, 21 females; mean age: 3.38 ± 3.11 years; range: 1.8 months to 10 years; heart rate: 136.8 ± 14.7 bpm). Written informed consent, including adverse reactions to the iodinated contrast agent and radiation exposure, was obtained from the guardians of the patients.

DSCT

All examinations were performed using a DSCT scanner (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany). Short-term sedation was achieved by an intravenous injection of chloral hydrate (concentration: 10%, 0.5 ml/kg) to the patients <6 years of age. The rest of the patients were asked to hold their breath during the scanning. The scanning was performed in the craniocaudal direction from the inlet of the thorax to 2 cm below the diaphragm level. A nonionic contrast agent (iopamidol, 370 mg/ml, Bracco, Sine Pharmaceutical Corp. Ltd., Shanghai China) was injected into an antecubital vein at a rate of 1.2–2.5 ml/s, followed by 20 ml of saline solution. The injected volume was adjusted to the body weight (1.5 ml/kg). Bolus tracking was used in a region of interest (ROI) in the descending aorta (Ao) with a predefined threshold of 100 HU. Image acquisition was triggered following a delay of 5 s when the ROI attenuation threshold reached 100 HU. Scanning was performed using a retrospective ECG-gated protocol with the following acquisition parameters: tube voltage, 80 kV; tube current, 100 mAs; gantry rotation time, 0.28 s; and pitch, 0.2–0.5 (selected according to heart rate; a higher pitch was used for higher heart rates). The ECG-pulsing window was set on Auto.

All acquired data were processed on a workstation (Syngo; Siemens Medical System, Forchheim, Germany). A slice thickness of 0.75 mm and an increment of 0.7 mm were chosen for image reconstruction. The multiplanar reformation (MPR), maximum intensity projection (MIP), and volume rendering (VR) were used for image analysis.

Image analysis

Two experienced radiologists analyzed each subject in a blinded fashion. They analyzed and recorded the location of the ventricular septal defect (VSD), alignment of the two great arteries, and associated malformations using a sequential segmental approach. Disagreement was negotiated before the final diagnosis was given.

According to Lev et al., there are four types of VSD, depending on the location of VSD relative to the two arterial valves [9]. If VSD was close to the aortic valve with its superior border lower than the inferior border of the aortic valve, it was termed a subaortic VSD (Figs 1b and 2b). In a similar manner, if VSD was close to the pulmonary valve with its superior border lower than the inferior border of the pulmonary valve, it was termed a subpulmonary VSD (Fig 3b), and if VSD was under both the aortic and pulmonary valves with equal distance, it was termed a double-committed VSD (Fig 4b). In a subset of patients, the distance between VSD and the two arterial valves was greater than the diameter of the Ao, which was termed a noncommitted VSD (Fig 5b) [10, 11]. The alignment of the two great arteries was determined by an angle between two specific lines. One was delineated to connect the sternum and center of the thoracic vertebral body and the other connected the two great arteries [11]. The measured angle increased as the line between the two great arteries rotated clockwise. The above measurement was performed on the transverse view through pulmonary bifurcation. If the Ao was posterior and to the right of the main pulmonary artery (MPA), in other words, 0° ≤ the measured angle < 90°, it was termed the RP position (Fig 1a); if two great arteries were side-by-side, in other words, the measured angle was equal to 90° or 270°, it was termed the side-by-side position (Fig 4a); if the Ao was anterior and to the right of the MPA (90° < the measured angle ≤ 180°), it was termed the RA position (Figs 3a and 5a); if the Ao was anterior and to the left of the MPA (180° < the measured angle < 270°), it was termed the LA position (Fig 2a).

thumbnail
Fig 1. DORV with subaortic VSD in a male aged 9 months.

(a) The aorta (Ao) was posterior and to the right of the main pulmonary artery (MPA) (the measured angle = 24°). (b) The VSD was situated below the aortic valve. (c) A ductus arteriosus (arrow) extended from the aortic arch to the MPA. LPA, left pulmonary artery; LV, left ventricle; RAA, right auricular appendage; RPA, right pulmonary artery; RV, right ventricle; PDA, Patent ductus arteriosus.

https://doi.org/10.1371/journal.pone.0130987.g001

thumbnail
Fig 2. DORV with subaortic VSD in a female aged 6 years.

(a) The aorta (Ao) was anterior and to the left of the main pulmonary artery (MPA) (the measured angle = 241°). (b) The VSD was situated below the aortic valve. (c) The volume rendering (VP) image showed the left pulmonary artery (LPA) stenosis (arrow) and the persistent left superior vena cava (star), as shown in Fig 2a. LAA, left auricular appendage; LV, left ventricle; RPA, right pulmonary artery; RV, right ventricle.

https://doi.org/10.1371/journal.pone.0130987.g002

thumbnail
Fig 3. DORV with subpulmonary VSD in a female aged 3 years.

(a) The aorta (Ao) was anterior and to the right of the main pulmonary artery (MPA) (the measured angle = 120°). (b) The VSD was situated below the pulmonary valve. (c) The volume rendering (VP) image showed the total anomalous pulmonary venous connection of the intracardiac type with 4 pulmonary veins (arrows) draining to the coronary sinus. LPA, left pulmonary artery; LV, left ventricle; RPA, right pulmonary artery; RV, right ventricle.

https://doi.org/10.1371/journal.pone.0130987.g003

thumbnail
Fig 4. DORV with double-committed VSD in a female aged 3 months.

(a) The two great arteries were side-by-side (the measured angle = 90°). (b) The VSD was situated below both the two arterial valves. (c) The volume rendering (VP) image showed the coarctation of the aorta (arrow) with poststenotic dilatation. Ao, aorta; LA, left atrium; MPA, main pulmonary artery; RA, right atrium; RPA, right pulmonary artery.

https://doi.org/10.1371/journal.pone.0130987.g004

thumbnail
Fig 5. DORV with noncommitted VSD in a female aged 7 years.

(a) The aorta (Ao) was anterior and to the right of the main pulmonary artery (MPA) (the measured angle = 167°). (b) The VSD (arrow) is far from both the two arterial valves. (c) The volume rendering (VP) image showed the dysplasia of the left anterior descending artery (LAD) and anomalous course of the left circumflex artery (LCX) crossing anterior of the left auricular appendage (LAA). LA, left atrium; LPA, left pulmonary artery; LV, left ventricle; MPA, main pulmonary artery; RPA, right pulmonary artery; RV, right ventricle.

https://doi.org/10.1371/journal.pone.0130987.g005

In addition, to compare the diagnostic accuracies of DSCT with that of TTE, we categorized all the surgically confirmed malformations into four groups, i.e., intracardiac anomalies, coronary artery anomalies (CAAs), anomalies of great vessels, and separate thoracic and abdominal anomalies. Intracardiac anomalies included right ventricular outflow tract stenosis, pulmonary valve stenosis, atrial septal defect, tricuspid atresia, and bicuspid pulmonary valve. Anomalies of great vessels included pulmonary artery anomalies, persistent left superior vena cava, anomalous pulmonary venous connection, patent ductus arteriosus, right aortic arch, interrupted aortic arch, and coarctation of the aorta. Separate thoracic and abdominal anomalies referred to situs inversus and aortopulmonary collateral vessels.

Assessment of image quality

The overall image quality of retrospective ECG-gated DSCT was evaluated by the above-mentioned two radiologists using a four-point scale in which 4 = excellent (excellent image quality, excellent anatomic details), 3 = good (good image quality, clear visualization of anatomic details), 2 = fair (fair image quality, anatomic structures required clinically could be identified), and 1 = poor (poor image quality, severe artifacts that incomplete or no useful anatomic information obtained). A score of 3 or 4 was considered to be diagnostic. Differences in opinions were resolved by discussion to reach a consensus.

Trans-thoracic echocardiography

All patients underwent TTE preoperatively using a Philips SONOS 7500 ultrasound system (Philips Medical Systems, Bothell, WA). The examinations were performed on the basis of recommendations of the America Society of Echocardiography Committee [12]. An experienced echocardiographic investigator who was not involved in the DSCT diagnostics interpreted the TTE in a blind fashion.

Radiation dose estimation

Radiation dose parameters, including volume CT dose index (CTDIvol) and dose-length product (DLP) were automatically displayed on the CT console after the examination. Infant-specific DLP conversion coefficients, based on the 2007 recommendations of the International Commission on Radiological Protection, were used to calculate the effective dose (ED) using conversion coefficients of 0.039 for patients <4 months of age, 0.026 for patients between 4 months and 1 year of age, 0.018 for patients between 1 and 6 years of age, and 0.012 for patients between 6 and 10 years of age [6, 13, 14].

Statistical analysis

The assembled data were analyzed using the SPSS software for Windows (version 19.0, SPSS Inc., Chicago, IL, USA). The sensitivity, specificity, positive predictive value, and negative predictive value of DSCT and TTE were evaluated for intracardiac anomalies, CAAs, anomalies of great vessels, and separate thoracic and abdominal anomalies groups. Continuous variables were presented as means ± standards deviations. Categorical variables were expressed as numbers and percentages. Agreement of image quality and diagnosis of associated malformations between DSCT and TTE were assessed using the kappa value. Kappa values of 0.61–0.80 were considered to indicate good agreement and 0.81–1.00 were considered to indicate excellent agreement.

Results

Assessment of image quality

DSCT scanning were successfully performed in all the 47 pediatric patients. After consensus, the mean image quality score of 47 cases was 3.70 ± 0.46. All the DSCT images were considered as diagnostic, including 70.2% (33/47) were scores of 4, and 29.8% (14/47) were scores of 3. The interobserver agreement of image quality was calculated as κ = 0.76, which indicated good agreement.

Associated multiple malformations

Apart from DORV, there were a total of 109 associated malformations confirmed by surgical results. A summary of the findings obtained with DSCT and TTE are shown in Table 1. DSCT missed detecting one bicuspid pulmonary valve (1/8) and three atrial septal defects (3/9) in addition to misdiagnosing one atrial septal defect (1/38) and one bicuspid pulmonary valve (1/39). TTE missed detecting one pulmonary artery anomaly (1/11), one aortopulmonary collateral vessel (1/10), one anomalous pulmonary venous connection (1/6), one interrupted aortic arch (1/2), one coarctation of the aorta (1/5), two cases of situs inversus (2/3), and three CAAs (3/15) in addition to misdiagnosing one pulmonary artery anomaly (1/36). The agreement of diagnosis of associated malformations between the two methods was calculated as κ = 0.90, which indicated excellent agreement. The sensitivity, specificity, positive predictive value, and negative predictive value of DSCT and TTE for each group are presented in Table 2.

thumbnail
Table 1. A summary of the findings obtained with DSCT and TTE (n = 47).

https://doi.org/10.1371/journal.pone.0130987.t001

thumbnail
Table 2. The diagnostic accuracies of DSCT and TTE according to anomalies categories.

https://doi.org/10.1371/journal.pone.0130987.t002

Location of VSD and alignment of the two great arteries

The locations of VSD and the alignments of the two great arteries are listed in Table 3. Among the 47 cases, subaortic VSD was observed in 57.4% (27/47) of the cases, subpulmonary VSD was observed in 23.4% (11/47), double-committed VSD was observed in 14.9% (7/47), and noncommitted VSD was observed in 4.2% (2/47).

thumbnail
Table 3. The locations of VSD and the alignments of the two great arteries.

https://doi.org/10.1371/journal.pone.0130987.t003

The results for the alignment of the two great arteries showed that 34.0% (16/47) of the alignments were classified as the RP position, of which 75.0% (12/16) were subaortic VSD; 25.5% (12/47) were classified as the side-by-side position, of which 41.7% (5/12) and 33.3% (4/12) were double-committed VSD and subaortic VSD, respectively; 27.6% (13/47) were classified as the RA position, of which 46.2% (6/13) and 38.4% (5/13) were subaortic VSD and subpulmonary VSD, respectively; and 12.7% (6/47) were classified as the LA position, of which 83.3% (5/6) was subaortic VSD.

Radiation dose estimation

As shown in Table 4, the mean DLP for patients <4 months of age was 31.11 ± 12.42 mGy·cm, which corresponds to an estimated mean ED of 1.21 ± 0.48 mSv. The mean DLP for patients between 4 months and 1 year of age was 40.77 ± 6.53 mGy·cm, which corresponds to an estimated mean ED of 1.06 ± 0.17 mSv. The mean DLP for patients between 1 and 6 years of age was 50.13 ± 2.73 mGy·cm, which corresponds to an estimated mean ED of 0.90 ± 0.18 mSv. The mean DLP for patients between 6 and 10 years of age was 46.28 ± 13.00 mGy·cm, which corresponds to an estimated mean ED of 0.55 ± 0.15 mSv. The estimated mean effective dose was 0.88 ± 0.34 mSv (<1 mSv).

thumbnail
Table 4. Radiation dose estimation according to different age groups.

https://doi.org/10.1371/journal.pone.0130987.t004

Discussion

With high temporal resolution and fast scanning speed, DSCT has been widely used for pediatric cardiac examinations in recent years. However, the pediatric population is sensitive to ionizing radiation, and radiation exposure will increase their potential cancer risk. Li et al. reported that there was a negative correlation between radiation effect and patient age [15]. Therefore, minimizing the delivered radiation dose is necessary whenever possible, particularly in pediatric patients.

In this study, scanning was performed using a retrospective ECG-gated protocol rather than a prospective ECG-gated protocol. Although the radiation dose of the prospective ECG-gated protocol was lower than that of the retrospective ECG-gated protocol [8, 16], the former is characterized by acquiring data from a programmed triggering point in every cardiac cycle, which relies on low and stable heart rhythm for diagnostic image quality [5, 17]. Thus, in cases with relatively high or unstable heart rhythm, the achieved image quality, particularly of intracardiac structures and coronary arteries, is unsatisfactory because the start point of data acquisition is not compatible with the cardiac cycle [6, 8]. In contrast, the retrospective ECG-gated protocol has the ability to perform ECG editing, which is a technique that regulates the position of the ECG-pulsing window within the cardiac cycle to adapt to the relatively high or irregular heart rhythm [18]. Then, the acquired data will be retrospectively selected for image reconstruction. Thus, with respect to pediatric patients with relatively high or unstable heart rhythm, these procedures can provide high-quality images with minimal artifacts, particularly of intracardiac details and coronary arteries.

How to reduce radiation dose is the most important issue when undergoing cardiac CT because young patients are more radiosensitive than adults [19]. We took several measures to reduce radiation dose. First, tube voltage is one of the major factors that affect radiation exposure. In this study, the tube voltage was set at a low level of 80 kV. Decreasing the tube voltage will not merely decrease radiation exposure. Actually, for cardiac CT, low tube voltage not only achieves higher vascular enhancement without the loss of contrast-to-noise ratio but also reduces the contrast agent dose [20, 21]. Second, data were acquired using an ECG-based tube current modulation technique. That means that during the prescribed R–R interval (ECG-pulsing window), the tube current was preset at full dose, whereas in the remainder of the R–R interval, the tube current was reduced to a low level of 4%–20% of the full dose, which dramatically reduced the radiation exposure [22]. Third, the heart rhythm adaptive pitch, a technique that allows for an increase in pitch to fit a high heart rhythm, was applied. According to McCollough et al., increasing the pitch from 0.20 to 0.46 will decrease the CTDIvol by nearly 57% [23]. Therefore, the heart rhythm adaptive pitch will further reduce radiation exposure and shorten the duration of examination, particularly in pediatric patients with elevated or irregular heart rhythm who cannot hold their breath well. In summary, the estimated mean ED was <1 mSv (0.88 ± 0.34 mSv) because the above-mentioned measures were applied, which was acceptable for pediatric patients.

According to the data presented in Table 2, DSCT appears to be slightly inferior to TTE for the detection of intracardiac anomalies (sensitivity: DSCT, 91.30%; TTE, 100%). DSCT missed several tiny anomalies such as atrial septal defect (3/9) and bicuspid pulmonary valve (1/8). The reason is that DSCT imaging is a digital-based technology that requires a workstation to convert digital information to gray-scale images; thus, some intracardiac details are too tiny to demonstrate with certainty. Under this circumstance, we could not make an exact decision at times on whether the anomalies existed or not, which means that there was a possibility of missed diagnoses. However, dynamic functional sequels and color Doppler flow imaging are unique advantages of TTE that enable the detection of such tiny anomalies and enable dynamic assessments of intracardiac structures and cardiac functions [24]. In the recent years, however, several studies have shown that retrospective ECG-gated DSCT is feasible for evaluating the dynamic characteristics of the heart [25, 26], but TTE appears to be more flexible and convenient.

CAAs are usually associated with complex CHD. Yu et al. reported that the prevalence of CCAs in DORV was approximately 21.43% [27]. Our study had 15 cases (15/47, 31.91%) with CAAs. Therefore, the visualization of the origin and distribution of the anomalous coronary arteries preoperatively is critical for reducing the risk of surgery. Table 2 indicates that DSCT was more suitable than was TTE for the detection of coronary arteries (sensitivity: DSCT, 100%; TTE, 80.00%) because of its powerful data postprocessing techniques such as MPR, MIP, and VP. The limitation of TTE in providing three-dimensional information impaired its ability for the successful diagnosis of CAAs by increasing the rate of false negatives (DSCT, 0%; TTE, 25.00%) [28].

In addition, DSCT was superior to TTE in detecting anomalies of great vessels and separate thoracic and abdominal anomalies (sensitivity, anomalies of great vessels: DSCT, 100%; TTE, 88.57%; separate thoracic and abdominal anomalies: DSCT, 100%; TTE, 76.92%). DSCT can visualize noncardiac anatomical details and gives a wide field of view of the thorax and abdomen. Nevertheless, the diagnostic value of TTE, particularly for the distal segment of great vessels and separate abdominal anomalies, is restricting because of its limited acoustic window [24, 29]. Furthermore, the experience of the echocardiographic investigator should not be neglected as well.

Our study suggested that retrospective ECG-gated DSCT has satisfactory diagnostic accuracy in the preoperative assessment of DORV and associated multiple malformations in pediatric patients and can provide excellent diagnostic image quality without the disadvantage of increasing the radiation dose. However, it has the possibility of missed diagnoses for tiny intracardiac malformations. So combining the results of DSCT and TTE would prove beneficial to guarantee the diagnostic accuracy of DSCT in these malformations.

Limitations

We need to acknowledge several limitations of this study. First, we included a relatively small number of patients, which limits us to extend our results to a large group. Second, although retrospective ECG-gated DSCT was an accurate modality demonstrating intra- and extracardiac malformations, however, it had the possibility of missed diagnoses for tiny intracardiac malformations such as atrial septal defect due to its image resolution limitation. Hence, we should combine the results of the two modalities if DSCT could not determine those malformations. Third, like TTE, retrospective ECG-gated DSCT is capable of analyzing cardiac function and providing hemodynamic information. We could not provide the functional information, especially the right ventricular function, which was helpful in the assessment of DORV. We expect that in the future, more studies will focus on the assessment of cardiac function in DORV patients by using retrospective ECG-gated DSCT.

In summary, retrospective ECG-gated DSCT is a better diagnostic tool than TTE for pediatric patients with complex congenital heart disease such as DORV. Combined with TTE, it may reduce or even obviate the use of invasive cardiac catheterization, and thus exposing the patients in a much lower radiation dose.

Author Contributions

Conceived and designed the experiments: KS ZY YG. Performed the experiments: KS JC GZ HX. Analyzed the data: KS JC HX. Contributed reagents/materials/analysis tools: KS JC GZ. Wrote the paper: KS ZY YG.

References

  1. 1. Walters HL 3rd, Mavroudis C, Tchervenkov CI, Jacobs JP, Lacour-Gayet F, Jacobs ML. Congenital Heart Surgery Nomenclature and Database Project: double outlet right ventricle. Ann Thorac Surg 2000; 69:S249–263. pmid:10798433
  2. 2. Vitiello R, McCrindle BW, Nykanen D, Freedom RM, Benson LN. Complications associated with pediatric cardiac catheterization. J Am Coll Cardiol 1998; 32:1433–1440. pmid:9809959
  3. 3. Tangcharoen T, Bell A, Hegde S, Hussain T, Beerbaum P, Schaeffter T, et al. Detection of coronary artery anomalies in infants and young children with congenital heart disease by using MR imaging. Radiology 2011; 259:240–247. pmid:21325034
  4. 4. Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Süss C, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006; 16:256–268. pmid:16341833
  5. 5. Lell M, Marwan M, Schepis T, Pflederer T, Anders K, Flohr T, et al. Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol 2009; 19:2576–2583. pmid:19760421
  6. 6. Nie P, Wang X, Cheng Z, Ji X, Duan Y, Chen J. Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease. Eur Radiol 2012; 22:2057–2066. pmid:22592808
  7. 7. Walsh R, Nielsen JC, Ko HH, Sanz J, Srivastava S, Parness IA, et al. Imaging of congenital coronary artery anomalies. Pediatr Radiol 2011; 41:1526–1535. pmid:22127684
  8. 8. Jin KN, Park EA, Shin CI, Lee W, Chung JW, Park JH. Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose. Int J Cardiovasc Imaging 2010; 26 Suppl 1:63–73. pmid:20044793
  9. 9. Lev M, Bharati S, Meng CC, Liberthson RR, Paul MH, Idriss F. A concept of double-outlet right ventricle. J Thorac Cardiovasc Surg 1972; 64:271–281. pmid:5048382
  10. 10. Belli E, Serraf A, Lacour-Gayet F, Hubler M, Zoghby J, Houyel L, et al. Double-outlet right ventricle with non-committed ventricular septal defect. Eur J Cardiothorac Surg 1999; 15:747–752. pmid:10431853
  11. 11. Chen SJ, Lin MT, Liu KL, Chang CI, Chen HY, Wang JK, et al. Usefulness of 3D reconstructed computed tomography imaging for double outlet right ventricle. J Formos Med Assoc 2008; 107:371–380. pmid:18492621
  12. 12. Lai WW, Geva T, Shirali GS, Frommelt PC, Humes RA, Brook MM, et al. Guidelines and Standards for Performance of a Pediatric Echocardiogram: A Report from the Task Force of the Pediatric Council of the American Society of Echocardiography. J Am Soc Echocardiogr 2006; 19:1413–1430. pmid:17138024
  13. 13. The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 2007; 37:1–332.
  14. 14. Deak PD, Smal Y, Kalender WA. Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 2010; 257:158–166. pmid:20851940
  15. 15. Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific radiation dose and cancer risk for pediatric chest CT. Radiology 2011; 259:862–874. pmid:21467251
  16. 16. Sun Z, Ng KH. Prospective versus retrospective ECG-gated multislice CT coronary angiography: a systematic review of radiation dose and diagnostic accuracy. Eur J Radiol 2012; 81:e94–100. pmid:21316887
  17. 17. Stolzmann P, Goetti R, Baumueller S, Plass A, Falk V, Scheffel H, et al. Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates. Eur J Radiol 2011; 79:85–91. pmid:20079993
  18. 18. Hirai N, Horiguchi J, Fujioka C, Kiguchi M, Yamamoto H, Matsuura N, et al. Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 2008; 248:424–430. pmid:18574140
  19. 19. National Research Council of the National Academies Board on Radiation Effects Research. Health risks from exposure to low levels of ionizing radiation: BEIR VII phase 2. Washington, DC: The National Academies Press; 2006.
  20. 20. Faggioni L, Neri E, Sbragia P, Pascale R, D'Errico L, Caramella D, et al. 80-kV pulmonary CT angiography with 40 mL of iodinated contrast material in lean patients: comparison of vascular enhancement with iodixanol (320 mg I/mL) and iomeprol (400 mg I/mL). AJR Am J Roentgenol 2012; 199:1220–1225. pmid:23169711
  21. 21. Huda W, Tipnis S, Sterzik A, Schoepf UJ. Computing effective dose in cardiac CT. Phys Med Biol 2010; 55:3675–3684. pmid:20530853
  22. 22. Stolzmann P, Scheffel H, Schertler T, Frauenfelder T, Leschka S, Husmann L, et al. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 2008; 18:592–599. pmid:17909816
  23. 23. McCollough CH, Primak AN, Saba O, Bruder H, Stierstorfer K, Raupach R, et al. Dose performance of a 64-channel dual-source CT scanner. Radiology 2007; 243:775–784. pmid:17446525
  24. 24. Beier UH, Jelnin V, Jain S, Ruiz CE. Cardiac Computed Tomography Compared to Transthoracic Echocardiography in the Management of Congenital Heart Disease. Catheter Cardiovasc Interv 2006; 68:441–449. pmid:16897779
  25. 25. Mahnken AH, Bruners P, Bornikoel CM, Flohr T, Schmidt B, Völk M, et al. Dual-source CT assessment of ventricular function in healthy and infarcted myocardium: an animal study. Eur J Radiol 2011; 77:443–449. pmid:19709834
  26. 26. Deng W, Yang ZG, Peng LQ, Dong ZH, Chu ZG, Wang QL. Morphological and dynamic features of normal mitral valve evaluated by dual-source computed tomography. Int J Cardiol 2010; 145:633–636. pmid:21035880
  27. 27. Yu FF, Lu B, Gao Y, Hou ZH, Schoepf UJ, Spearman JV, et al. Congenital anomalies of coronary arteries in complex congenital heart disease: Diagnosis and analysis with dual-source CT. J Cardiovasc Comput Tomogr 2013; 7:383–390. pmid:24331934
  28. 28. Bishnoi RN, McMillan KN, Thompson WR. Unusual sudden cardiac death from an anomalous left coronary artery from the right sinus of Valsalva. Cardiol Young 2014; 24:732–734. pmid:23880063
  29. 29. Wang TL, Hung HF, Lin C, Hsiung MC, Wei J. Multiple anomalous left pulmonary venous connections detected with transthoracic echocardiography. J Cardiothorac Surg 2013; 8:130. pmid:23679936