Peer Review History

Original SubmissionAugust 23, 2022
Decision Letter - Hannes C Schniepp, Editor

PONE-D-22-23551Implementation of a cylindrical distribution function for the analysis of anisotropic molecular dynamics simulations.PLOS ONE

Dear Dr. Mandle,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Jan 02 2023 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.
  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.
  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Hannes C Schniepp, Dr. sc. nat.

Academic Editor

PLOS ONE

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf   

2. We note that the grant information you provided in the ‘Funding Information’ and ‘Financial Disclosure’ sections do not match.

When you resubmit, please ensure that you provide the correct grant numbers for the awards you received for your study in the ‘Funding Information’ section.

3. Please note that PLOS ONE has specific guidelines on code sharing for submissions in which author-generated code underpins the findings in the manuscript. In these cases, all author-generated code must be made available without restrictions upon publication of the work. Please review our guidelines at https://journals.plos.org/plosone/s/materials-and-software-sharing#loc-sharing-code and ensure that your code is shared in a way that follows best practice and facilitates reproducibility and reuse. New software must comply with the Open Source Definition

4. Thank you for stating the following financial disclosure:

“The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.”

At this time, please address the following queries:

a)        Please clarify the sources of funding (financial or material support) for your study. List the grants or organizations that supported your study, including funding received from your institution.

b)        State what role the funders took in the study. If the funders had no role in your study, please state: “The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.”

c)        If any authors received a salary from any of your funders, please state which authors and which funders.

d)        If you did not receive any funding for this study, please state: “The authors received no specific funding for this work.”

Please include your amended statements within your cover letter; we will change the online submission form on your behalf.

5. Thank you for stating the following in the Acknowledgments Section of your manuscript:

“Computational work was undertaken on ARC3, part of the high performance computing facilities at the University of Leeds, UK.  RJM thanks UKRI for funding via a Future Leaders Fellowship (grant no. MR/W006391/1), and the University of Leeds for funding via a University Academic Fellowship. Code for cylindr is available via GitHub (https://github.com/RichardMandle/cylindr)”

We note that you have provided additional information within the Acknowledgements Section that is not currently declared in your Funding Statement. Please note that funding information should not appear in the Acknowledgments section or other areas of your manuscript. We will only publish funding information present in the Funding Statement section of the online submission form.

Please remove any funding-related text from the manuscript and let us know how you would like to update your Funding Statement. Currently, your Funding Statement reads as follows:

 “The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.”

Please include your amended statements within your cover letter; we will change the online submission form on your behalf.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Partly

Reviewer #2: Partly

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: The manuscript describes analyses of a number of molecular dynamics simulations of anisotropic liquids. The author introduces the cylindrical distribution function (CDF), as a 2-dimensional pendant to the 1-dimensional radial distribution function and argues that more (relevant) information is conveyed in the CDF. The author introduces a python tool to easily perform such analyses, which is made available on github. This is a neat addition, that will be of use to scientists interested in such systems.

I would like to make the following comments:

1. In the introduction, the author describes the radial distribution function as well as parallel and perpendicular components, and orientational variants. This is done in a rather confusing way. I always think of a radial distribution function in terms of the number of particles I find at a particular position (shell of sphere, or a cylinder), relative to the number of particles I would expect in a homogeneous distribution (i.e. the number density times the volume of the shell). This is also the definition the author used for the CDF in equation 6.

a. Below equation 1, the author writes that r is the distance between the selected atoms. This would be r_ij, while r is the coordinate of g(r).

b. Below equation 1, N is described as the number density. As the sum in the equation runs up to N, I suspect N is rather the total number of particles considered. N/V is then the number density, assuming that V is the volume of the box. The author did not introduce the delta function, but let’s assume it is a unitless function that is 1 if its argument is 0 and 0 otherwise.

c. I then, do not see, why there is another division by N, and no correction for the volume of the radial shell (4*pi*r^2*dr). In short, I think the definition of g(r) should read: g(r) = V/(N*4*pi*r^2*dr)*sum_ij(delta(r-r_ij)).

d. Similarly, the description of the symbols under equations 2 and 3 is incomplete: n(r) is not the volume, but the number of particles; what is r_cut, what is r_||?

e. Below equations 4 and 5, the author may want to point out that u_i and u_j are vectors of length 1, and that the equations correspond to the Legendre polynomials.

2. The optimal number of shell increments per Ångstrom (the resolution; page 9) will depend on the number of molecules and the number of snapshots in the trajectories. The more pair-data is available, the finer grained the function can be determined.

3. I cannot follow the description of the very first CDF completely. The authors starts with explaining the high-probability regions at h = +/- 10 Å, r = 0. But the most pronounced maximum at r = 0, is still at h = +/- 5.5 Å, which seems small for the length of the molecule. This particular CDF looks very isotropic to me. Maybe the author can take the readers even more by the hand to emphasize the additional information that can be read from the CDF, compared to the RDF.

4. The bibliography of citation 19 seems incomplete.

Reviewer #2: The Author present a software tool for the evaluation of a bidimensional distribution function in order to study structural properties of fluids with particular emphasis on liquid crystals. The software is made freely available to the community working in the field.

The "cylindrical" distribution function appears to be a useful additional tool to evaluate the structural properties of ordered fluids, so the manuscript is in priciple publishable.

There are, however, a couple of issues that prevents me from recommending publication at this stage.

Considering the first example discussed, the 5CB case, first a general point:

- the Author compares the CDF with the RDF in Figure 2. Obviously the CDF contains a larger amount of information than the RDF, being resolved in two dimensions representing the distance along the director (the height of the cylinder) and the distance perpendicular to the drector (the radius). However does it contain more information than the pair of radial distribution functions resolved along the parallel and perpendicular directions, that is Eq. 2 and Eq. 3?

The second issue is the following: the Author states that "High probability regions at h=±10, r=0 Å result from antiparallel

pairs of molecules, and at h=0, r ~ 5.5 Å from side-by-side pairs." This should be apparent in Figure 2 a) but the bidimensional plot clearly shows that at r=0 the CDF has a maximum at h = +/- 5 (or just larger than 5), not +/- 10 . This seems to be a too short distance for two 5CB molecules on top of each other along the director. This result is not clealy expained.

These comments can be applied to the other examples too, especially the first one, that is: what are the really new additional information dsplayed by the CDF that cannot be found in RDF resolved along an perpendicularly to the director?

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Revision 1

A Formatted response is given in the cover letter; please see below for a copy/paste:

-----------------------------

RE:

“Implementation of a cylindrical distribution function for the analysis of anisotropic molecular dynamics simulations”, submitted for consideration in PLOS One.

Thank you for the review of this manuscript. The comments from both referees are constructive and largely positive, and have strengthened the revised version. I will now address the comments/queries from both referees.

Reviewer #1: The manuscript describes analyses of a number of molecular dynamics simulations of anisotropic liquids. The author introduces the cylindrical distribution function (CDF), as a 2-dimensional pendant to the 1-dimensional radial distribution function and argues that more (relevant) information is conveyed in the CDF. The author introduces a python tool to easily perform such analyses, which is made available on github. This is a neat addition, that will be of use to scientists interested in such systems.

I thank the referee for these supportive comments.

I would like to make the following comments:

1. In the introduction, the author describes the radial distribution function as well as parallel and perpendicular components, and orientational variants. This is done in a rather confusing way. I always think of a radial distribution function in terms of the number of particles I find at a particular position (shell of sphere, or a cylinder), relative to the number of particles I would expect in a homogeneous distribution (i.e. the number density times the volume of the shell). This is also the definition the author used for the CDF in equation 6.

a. Below equation 1, the author writes that r is the distance between the selected atoms. This would be r_ij, while r is the coordinate of g(r).

b. Below equation 1, N is described as the number density. As the sum in the equation runs up to N, I suspect N is rather the total number of particles considered. N/V is then the number density, assuming that V is the volume of the box. The author did not introduce the delta function, but let’s assume it is a unitless function that is 1 if its argument is 0 and 0 otherwise.

c. I then, do not see, why there is another division by N, and no correction for the volume of the radial shell (4*pi*r^2*dr). In short, I think the definition of g(r) should read: g(r) = V/(N*4*pi*r^2*dr)*sum_ij(delta(r-r_ij)).

d. Similarly, the description of the symbols under equations 2 and 3 is incomplete: n(r) is not the volume, but the number of particles; what is r_cut, what is r_||?

e. Below equations 4 and 5, the author may want to point out that u_i and u_j are vectors of length 1, and that the equations correspond to the Legendre polynomials.

Firstly I want to apologise as the introduction to the manuscript is – on reflection – not well written, with key information missing, incomplete description of equations, and errors. I can only apologise for presenting such sloppy work. I will address each comment – (a) through to (e) in turn.

The referee is quite correct here that in equation 1 N is the total number of particles considered and not the number density as is written in the text. The erroneous text has been changed:

“…N is the number of molecules in the simulation…”

And additionally, the delta in eq. 1 has been defined in the text as the Dirac delta function:

“…and δ is the Dirac delta function.”

The referee is correct, eq. 1 should read:

g(r)=V/(N4πr^2 ∆r) ⟨├ ∑_ij^N▒δ(r-r_ij ) ⟩┤ eq. 1

And I also include text below:

“…, r is the radius of the spherical shell, ∆r is the thickness of the spherical shell, …”

The referee is also correct that, in reference to equations 2 and 3, n(r) is described in the text as being “the volume of the molecules contained within a cylindrical volume…” which is not correct, rather n(r) is the “number of molecules contained within a cylindrical volume…”, and the manuscript text has been amended to reflect this.

r_cutis defined in the text as:

“…where r_cut is the cut-off value used for calculating the distribution function.”

Text has been added (additions highlighted in yellow):

“Where u_i and u_j are two vectors of unit length describing the orientation of the ith and jth molecules, respectively, and r is the distance between the centre-of-mass (or selected atoms) of these same two molecules, with eq. 4 and eq. 5 corresponding to the Legendre polynomials.”

2. The optimal number of shell increments per Ångstrom (the resolution; page 9) will depend on the number of molecules and the number of snapshots in the trajectories. The more pair-data is available, the finer grained the function can be determined.

Yes this is correct and an interesting point, in future we could set a ‘default’ resolution on the fly depending on how fine the available trajectory data is, but I consider this something to add to a future version of the code. Of course we need to provide a means for a user specified value as calculating the CDF for very large simulations the Numpy arrays can consume a lot of RAM, and decreasing the resolution is one way to get around this.

3. I cannot follow the description of the very first CDF completely. The authors starts with explaining the high-probability regions at h = +/- 10 Å, r = 0. But the most pronounced maximum at r = 0, is still at h = +/- 5.5 Å, which seems small for the length of the molecule. This particular CDF looks very isotropic to me. Maybe the author can take the readers even more by the hand to emphasize the additional information that can be read from the CDF, compared to the RDF.

On re-reading the manuscript I share this view; after recalculating the CDF taking various cuts, I find I had originally included a CDF with the cylinder length perpendicular to the director rather than parallel to it. I have recomputed the CDF – both parallel and perpendicular – for the same trajectory, and included an additional graphic that shows the difference (Fig 1b).

The text has been amended (additions in yellow):

“Both CDF orientations show a region of zero probability centred at h=r=0 Å, which results from steric repulsion of molecules. High probability regions at h=±13, r=0 Å and h=±18, r=0 Å result from antiparallel pairs of molecules, and at h=0, r ~ 5.5 Å from side-by-side pairs. A series of arcs centred on h=0 Å occur every r ~5.5 Å as a consequence of side-by-side packing of molecules; the first arc being the neighbouring molecule(s), the second being the neighbour of neighbours and so on. The diffusivity of all features indicates a lack of positional order, as expected for the nematic state. For the CDF oriented perpendicular to the director we see diffuse concentric rings every r ~5.5 Å , the origins of these being neighbouring molecules as discussed above.”

Following the comments of Referee 2, I have also calculated the RDF for this trajectory of 5CB and resolved into its parallel and perpendicular components. Even for a this simple case (a conventional nematic) we can see that the CDF provides extra information, with the overlap of on-axis and off-axis features which result from quite subtle close-contacts between neighbours-of-neighbours.

New text, updated figure 2 and caption below:

“By resolving the RDF into components perpendicular and parallel to the director (Fig. 2f) we can see the same features present in the CDF. However, resolving the RDF in this way neglects off-axis interactions; a rather subtle example is the overlap of the ‘on-axis’ arcs (at h~ 10-12, r ~ 0-6 Å) with the off-axis arc that results from the lateral ‘neighbour-of-neighbours’ (at h ~ -10-10, r ~ 6-9 Å). This subtle anisotropy in local positioning manifests in variations in intensity in the concentric rings in the perpendicular CDF plot (Fig. 2e) which is not apparent from the resolved RDF (Fig. 2f).

Figure 2: (a) Molecular structure and transition temperatures (°C) of 5CB; (b) instantaneous configuration of 5CB in the nematic phase at 293 K, the simulation has <P2> = 0.56 ± 0.019 over the 50 ns MD run; (c) schematic showing the nematic director from (b) as a red arrow, and (exaggerated) cylindrical shells whose radius (∆r) forms a plane orthogonal (∆r_(||)) or parallel (〖∆r〗_⊥) to the director, used to calculate the CDF parallel and perpendicular to the director, respectively; (d) parallel and (e) perpendicular CDF plots for the nematic simulation of 5CB as generated by cylindr; (f) radial distribution functions (RDF) for the same simulation, with the RDF resolved into parallel and perpendicular components according to eq. 2 and eq. 3.

4. The bibliography of citation 19 seems incomplete.

Reference 19 has been corrected.

Reviewer #2: The Author present a software tool for the evaluation of a bidimensional distribution function in order to study structural properties of fluids with particular emphasis on liquid crystals. The software is made freely available to the community working in the field.

The "cylindrical" distribution function appears to be a useful additional tool to evaluate the structural properties of ordered fluids, so the manuscript is in priciple publishable.

There are, however, a couple of issues that prevents me from recommending publication at this stage.

Considering the first example discussed, the 5CB case, first a general point:

- the Author compares the CDF with the RDF in Figure 2. Obviously the CDF contains a larger amount of information than the RDF, being resolved in two dimensions representing the distance along the director (the height of the cylinder) and the distance perpendicular to the drector (the radius). However does it contain more information than the pair of radial distribution functions resolved along the parallel and perpendicular directions, that is Eq. 2 and Eq. 3?

The referee raises an important point. I would suggest that the CDF does yield additional information than the RDF resolved into two dimensions (as in Eq. 2, Eq. 3) as the explicit spatial relation between features is preserved. When resolving the RDF in this way we lose positional information in the ‘other’ direction, e.g. if we resolve the RDF parallel to the director then we neglect information about radial separation (and vice versa).

I have added text on pg. 2:

“… and so information about the spatial relationship between features is preserved.”

The response to the next comment (below) also addresses some of these highlighted issues.

The second issue is the following: the Author states that "High probability regions at h=±10, r=0 Å result from antiparallel

pairs of molecules, and at h=0, r ~ 5.5 Å from side-by-side pairs." This should be apparent in Figure 2 a) but the bidimensional plot clearly shows that at r=0 the CDF has a maximum at h = +/- 5 (or just larger than 5), not +/- 10 . This seems to be a too short distance for two 5CB molecules on top of each other along the director. This result is not clealy expained.

This was the result of my including the wrong CDF image (discussed in response to reviewer #1 also); in the original submission the presented CDF was for a cylinder oriented perpendicular to the director, not parallel as should have been the case. This has been corrected, and the revised plot shows the expected behaviour. The new Figure and caption reads:

Figure 2: (a) Molecular structure and transition temperatures (°C) of 5CB; (b) instantaneous configuration of 5CB in the nematic phase at 293 K, the simulation has <P2> = 0.56 ± 0.019 over the 50 ns MD run; (c) schematic showing the nematic director from (b) as a red arrow, and (exaggerated) cylindrical shells whose radius (∆r) forms a plane orthogonal (∆r_(||)) or parallel (〖∆r〗_⊥) to the director, used to calculate the CDF parallel and perpendicular to the director, respectively; (d) parallel and (e) perpendicular CDF plots for the nematic simulation of 5CB as generated by cylindr; (f) radial distribution functions (RDF) for the same simulation, with the RDF resolved into parallel and perpendicular components according to eq. 2 and eq. 3.

These comments can be applied to the other examples too, especially the first one, that is: what are the really new additional information dsplayed by the CDF that cannot be found in RDF resolved along an perpendicularly to the director?

I agree that this could have been illustrated better; clearly there are some instances where the CDF is superior to such a ‘resolved’ RDF, and some where is merely equal to them. We use 5CB as an exemplar to show how the CDF can capture additional detail to the resolved RDF case:

“By resolving the RDF into components perpendicular and parallel to the director (Fig. 2f) we can see the same features present in the CDF. However, resolving the RDF in this way neglects off-axis interactions; a rather subtle example is the overlap of the ‘on-axis’ arcs (at h~ 10-12, r ~ 0-6 Å) with the off-axis arc that results from the lateral ‘neighbour-of-neighbours’ (at h ~ -10-10, r ~ 6-9 Å). This subtle anisotropy in local positioning manifests in variations in intensity in the concentric rings in the perpendicular CDF plot (Fig. 2e) which is not apparent from the resolved RDF (Fig. 2f).

Of course, there will be cases which we have not thought of in which the CDF is superior to the resolved RDF, and this is our motivation for describing this software tool and releasing it for use by the community.

Finally, the editorial office asked for clarification regarding the funding of this work.

a) Please clarify the sources of funding (financial or material support) for your study. List the grants or organizations that supported your study, including funding received from your institution.

b) State what role the funders took in the study. If the funders had no role in your study, please state: “The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.”

c) If any authors received a salary from any of your funders, please state which authors and which funders.

d) If you did not receive any funding for this study, please state: “The authors received no specific funding for this work.”

In response:

UK Research and Innovation (UKRI) Future Leaders Fellowship to R. Mandle (grant no. MR/W006391/1); University of Leeds, University Academic Fellowship to R. Mandle (no grant number).

The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

I receive my salary from the University of Leeds.

We did receive funding for this work, see (a).

Yours Sincerely

Dr. Richard J. Mandle

UKRI Future Leaders Fellow &

University Academic Fellow

School of Chemistry & School of Physics and Astronomy

University of Leeds, Leeds, UK, LS2 9JT

Decision Letter - Hannes C Schniepp, Editor

Implementation of a cylindrical distribution function for the analysis of anisotropic molecular dynamics simulations.

PONE-D-22-23551R1

Dear Dr. Mandle,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Hannes C Schniepp, Dr. sc. nat.

Academic Editor

PLOS ONE

Additional Editor Comments (optional):

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.

Reviewer #1: All comments have been addressed

Reviewer #2: All comments have been addressed

**********

2. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: N/A

Reviewer #2: Yes

**********

4. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: (No Response)

Reviewer #2: (No Response)

**********

7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

**********

Formally Accepted
Acceptance Letter - Hannes C Schniepp, Editor

PONE-D-22-23551R1

Implementation of a cylindrical distribution function for the analysis of anisotropic molecular dynamics simulations.

Dear Dr. Mandle:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Hannes C Schniepp

Academic Editor

PLOS ONE

Open letter on the publication of peer review reports

PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.

We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.

Learn more at ASAPbio .