Peer Review History
Original SubmissionNovember 30, 2021 |
---|
PONE-D-21-37892Effectiveness of Android-based Integrated Diabetes Self-Management (IDSM) Application improving self-management and glycemic control of type 2 diabetes mellitus patients in Indonesia: a mixed methods study protocolPLOS ONE Dear Dr. Effendy, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. The manuscript has been evaluated by two reviewers, and their comments are available below. The reviewers have raised a number of concerns that need attention. They request additional information on methodological aspects of the study, including details regarding planned participants and recruitment, and they request further elaboration on the rationale for the study given the existence of similar studies in the literature. Please note that while the reviewer reference novelty PLOS ONE does not consider the novelty/impact of a study as part of our publication criteria; however we do require that the manuscript describes original research which is well justified and described, and analyses are performed to a high technical standard and are described in sufficient detail. The reviewers also requests copyediting of the manuscript to improve language and clarity Could you please revise the manuscript to carefully address the concerns raised? Please submit your revised manuscript by Jul 22 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Jamie Royle Staff Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and 2. Thank you for stating the following financial disclosure: The funders had and will not have a role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. At this time, please address the following queries: a) Please clarify the sources of funding (financial or material support) for your study. List the grants or organizations that supported your study, including funding received from your institution. b) State what role the funders took in the study. If the funders had no role in your study, please state: “The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.” c) If any authors received a salary from any of your funders, please state which authors and which funders. d) If you did not receive any funding for this study, please state: “The authors received no specific funding for this work.” Please include your amended statements within your cover letter; we will change the online submission form on your behalf. 3. Your ethics statement should only appear in the Methods section of your manuscript. If your ethics statement is written in any section besides the Methods, please delete it from any other section. 4. Please upload a copy of Supporting Information Figure 9 and 10 which you refer to in your text on page 18. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Partly Reviewer #2: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Partly Reviewer #2: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #1: No Reviewer #2: No ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: No Reviewer #2: No ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: No Reviewer #2: No ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The protocol entitled “Effectiveness of Android-based Integrated Diabetes Self-Management (IDSM) Application improving self-management and glycemic control of type 2 diabetes mellitus patients in indonesia: a mixed methods study protocol” expected to help optimize the implementation of diabetes self-management which can improve glycemic control of T2DM patients as one of the indicators of the Chronic Disease Care Program [Program Pengelolaan Penyakit Kronis (PROLANIS)] program in the PHC setting. The authors emphasized that there is no research publication that develop an Android-based integrated diabetes self-management application in Indonesia. However, many studies those application-based diabetes control in different countries of the World are available in the literature. The novelty of this study is not well described. The organizing of the manuscript is little complicated. The information periodically turns to the data analyze. The writing style must move away from a thesis style. I suggest to the authors to reorganize and summarize some parts for better understanding. Also, I believe there is no need to make a data analyze table. Reviewer #2: 1. Use the same format of referencing in whole paper. There are (2) and [3]. 2. There is no definition about diabetes self-management. 3. As you have a separate section called “study aims”, it is better to remove the last two line of “Background” that you wrote the aim of the study. 4. Will all the study phases be conducted in Public Health Center (PHC) in Yogyakarta city? How about for family members? How you will reach them? 5. What are the reason to do FGDs among patients in Phase 1? Will it let patients to participate in discussion by considering their own unique experiences? How about their gender, religious …composition? 6. Will other types of diabetes like T1DM… be considered as exclusion criteria? 7. How about a family member who has T2DM? will he/she be excluded? 8. What is sampling method for doctors? 9. Except “Peer debriefing and member checking” what other things you will do to increase trustworthiness? What about credibility? Transferability,.. 10. How and why you will choose “two PHCs” for data collection in phase 3? Why not more? 11. There is no any information about data collection tool for qualitative phases? How they will be developed and used? How about the translation? How long interviews will be conducted approximately? Where the interviews/FGDs will be conducted? 12. There is no more information about study procedure. How the target groups for different phases will be chosen? Who will be involved to recruit or conduct interviews? 13. How about ethical considerations like using information sheet? Consent form? How many versions you use? How about those who can’t read or write? 14. Please use reference to support “Measurement of self-management scores will be done three times each month after the intervention..” 15. One of the questions is that considering only T2DM patients who use Smartphone and can operate it will make ethical issues? What about those patients who can’t buy or will not have smartphone? 16. This paper should be edited by an English native. For example, “Phase 2, phase 2b will use the Think Aloud (TA) method. In this phase the researcher tested the Android-based IDSM Application to the user t to find problems in operating it. Participants who will involved are participants who have been given an explanation and give a consent.” ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Masoud Mohammadnezhad ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
Revision 1 |
PONE-D-21-37892R1Integrated Diabetes Self-Management (IDSM) mobile application to improve self-management and glycemic control among patients with Type 2 Diabetes Mellitus (T2DM) in indonesia: a mixed methods study protocol.PLOS ONE Dear Dr. Christantie Effendy, Thank you for submitting your revised manuscript. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Oct 06 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Jahanpour Alipour, Ph.D. Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. Additional Editor Comments: The authors improved the manuscript. However, it is necessary to consider the following concerns; -Authors should calculate the sample size considering the "two sided" test. The population is relatively small. -The authors mentioned that the control group will receive standard treatment via WhatsApp chat. Is this a standard treatment in Indonesia? How frequently the nurses will send messages to the participants? Is that a group based chat or personal communication will be allowed? The treatment for control group should be given in detail. -The age range of inclusion criteria should be reconsidered. How do you discriminate a Type 2 and Type 1 or Moody Type DM in a participant aged 18 years? [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Partly Reviewer #2: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Partly Reviewer #2: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: No Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors improved the manuscript. However, the following revisions are needed for better explaining; -Authors should calculate the sample size considering the "two sided" test. The population is relatively small. -The authors mentioned that the control group will receive standard treatment via Whatsapp chat. Is this a standard treatment in Indenosia? How frequently the nurses will send messages to the participants? Is that a group based chat or personal comminucation will be allowed? The treatment for control group should be given in detail. -The age range of inclusion criteria should be reconsidered. How do you discriminate a Type 2 and Type 1 or Moody Type DM in a participant aged 18 years? Reviewer #2: Thank you for addressing my comments. This study now sound very clear and can be published as it is. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Masoud Mohammadnezhad ********** [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. |
Revision 2 |
Integrated Diabetes Self-Management (IDSM) mobile application to improve self-management and glycemic control among patients with Type 2 Diabetes Mellitus (T2DM) in indonesia: a mixed methods study protocol. PONE-D-21-37892R2 Dear Dr. Christantie Effendy, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Jahanpour Alipour, Ph.D. Academic Editor PLOS ONE Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Does the manuscript provide a valid rationale for the proposed study, with clearly identified and justified research questions? The research question outlined is expected to address a valid academic problem or topic and contribute to the base of knowledge in the field. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Is the protocol technically sound and planned in a manner that will lead to a meaningful outcome and allow testing the stated hypotheses? The manuscript should describe the methods in sufficient detail to prevent undisclosed flexibility in the experimental procedure or analysis pipeline, including sufficient outcome-neutral conditions (e.g. necessary controls, absence of floor or ceiling effects) to test the proposed hypotheses and a statistical power analysis where applicable. As there may be aspects of the methodology and analysis which can only be refined once the work is undertaken, authors should outline potential assumptions and explicitly describe what aspects of the proposed analyses, if any, are exploratory. Reviewer #1: Yes Reviewer #2: Yes ********** 3. Is the methodology feasible and described in sufficient detail to allow the work to be replicable? Descriptions of methods and materials in the protocol should be reported in sufficient detail for another researcher to reproduce all experiments and analyses. The protocol should describe the appropriate controls, sample size calculations, and replication needed to ensure that the data are robust and reproducible. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors described where all data underlying the findings will be made available when the study is complete? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception, at the time of publication. The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above and, if applicable, provide comments about issues authors must address before this protocol can be accepted for publication. You may also include additional comments for the author, including concerns about research or publication ethics. You may also provide optional suggestions and comments to authors that they might find helpful in planning their study. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The study titled "Integrated Diabetes Self-Management (IDSM) mobile application to improve self-management and glycemic control among patients with Type 2 Diabetes Mellitus (T2DM) in indonesia: a mixed methods study protocol" is accepted as it is. Reviewer #2: Thank you for addressing the comments. I am happy with this version and recommend this paper to be published. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Masoud Mohammadnezhad ********** |
Formally Accepted |
PONE-D-21-37892R2 Integrated Diabetes Self-Management (IDSM) mobile application to improve selfmanagement and glycemic control among patients with Type 2 Diabetes Mellitus (T2DM) in Indonesia: a mixed methods study protocol Dear Dr. Effendy: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr., Jahanpour Alipour Academic Editor PLOS ONE |
Open letter on the publication of peer review reports
PLOS recognizes the benefits of transparency in the peer review process. Therefore, we enable the publication of all of the content of peer review and author responses alongside final, published articles. Reviewers remain anonymous, unless they choose to reveal their names.
We encourage other journals to join us in this initiative. We hope that our action inspires the community, including researchers, research funders, and research institutions, to recognize the benefits of published peer review reports for all parts of the research system.
Learn more at ASAPbio .