Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

< Back to Article

Fig 1.

Scheme of the periodic photonic crystal.

More »

Fig 1 Expand

Fig 2.

(a-c) Transmittance of periodic superconducting photonic crystal for PC2, PC3 and PC4, respectively. The other parameters are set as P=0 GPa, Te=4.2 K and θ=0 °.

More »

Fig 2 Expand

Fig 3.

(a) Moving tracks of the transmission peaks as the period number increases. (b) Electric field distribution of the superconducting PC3.

More »

Fig 3 Expand

Fig 4.

(a) The refractive index ns of the superconductor varying with the pressure and the frequency. (b) The refractive index nd of the dielectric layer varying with the pressure. The other parameters are set as Te=4.2 K and θ=0 °.

More »

Fig 4 Expand

Fig 5.

(a) Transmission spectra for different pressures. (b) Logarithm of the transmittance as the pressure changes. (c) Transmittance T and wavelength λc of the DM varying with the pressure. The other parameters are set as Te=4.2 K and θ=0 °.

More »

Fig 5 Expand

Fig 6.

(a) The real and imaginary parts of the superconductor refractive index varying with the temperature. (b) The refractive index of the dielectric layer varying with the temperature. The other parameters are set as P=0 GPa and θ=0 °.

More »

Fig 6 Expand

Fig 7.

(a) Transmission spectrum around the DM for different temperatures. (b) Logarithm of the transmittance as the temperature changes. (c) Transmittance comparison of the DM varying with the temperature between ns = ns(Te) and ns = 1. (d) Wavelength of the center peak varying with the temperature. The other parameters are set as P=0 GPa and θ=0 °.

More »

Fig 7 Expand

Fig 8.

(a) The refractive index of the superconductor varying with the frequency. (b) Transmission spectra for different incident angles. (c) Logarithm of the transmittance as the incident angle changes. (d) Transmittance and wavelength of the DM varying with the incident angle. The other parameters are set as P=0 GPa and Te=4.2 K.

More »

Fig 8 Expand

Fig 9.

(a-c) The sensitivity of the wavelength at the DM varying with the pressure (θ=0° and Te=4.2 K), incident angle (P=0 GPa and Te=4.2 K) and the temperature (P=0 GPa and θ=0°), respectively. (d) The sensitivity of the transmittance varying with the temperature (P=0 GPa and θ=0°).

More »

Fig 9 Expand

Table 1.

Pressure sensor comparison with recent investigations.

More »

Table 1 Expand