Assessment of intratumor hypoxia by integrated 18F-FDG PET / perfusion CT in a liver tumor model

  • Yong Wang,

    Affiliations Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China, Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada

  • Errol Stewart,

    Affiliation Imaging Program, Lawson Health Research Institute, London, Ontario, Canada

  • Lise Desjardins,

    Affiliation Imaging Program, Lawson Health Research Institute, London, Ontario, Canada

  • Jennifer Hadway,

    Affiliation Imaging Program, Lawson Health Research Institute, London, Ontario, Canada

  • Laura Morrison,

    Affiliation Imaging Program, Lawson Health Research Institute, London, Ontario, Canada

  • Cathie Crukley,

    Affiliation Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada

  • Ting-Yim Lee

    tlee@imaging.robarts.ca

    Affiliations Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada, Imaging Program, Lawson Health Research Institute, London, Ontario, Canada, Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada

Abstract

Objectives

Hypoxia in solid tumors occurs when metabolic demands in tumor cells surpass the delivery of oxygenated blood. We hypothesize that the 18F-fluorodeoxyglucose (18F-FDG) metabolism and tumor blood flow mismatch would correlate with tumor hypoxia.

Methods

Liver perfusion computed tomography (CT) and 18F-FDG positron emission tomography (PET) imaging were performed in twelve rabbit livers implanted with VX2 carcinoma. Under CT guidance, a fiber optic probe was inserted into the tumor to measure the partial pressure of oxygen (pO2). Tumor blood flow (BF) and standardized uptake value (SUV) were measured to calculate flow-metabolism ratio (FMR). Tumor hypoxia was further identified using pimonidazole immunohistochemical staining. Pearson correlation analysis was performed to determine the correlation between the imaging parameters and pO2 and pimonidazole staining.

Results

Weak correlations were found between blood volume (BV) and pO2 level (r = 0.425, P = 0.004), SUV and pO2 (r = -0.394, P = 0.007), FMR and pimonidazole staining score (r = -0.388, P = 0.031). However, there was stronger correlation between tumor FMR and pO2 level (r = 0.557, P < 0.001).

Conclusions

FMR correlated with tumor oxygenation and pimonidazole staining suggesting it may be a potential hypoxic imaging marker in liver tumor.

Introduction

Hypoxia, a hallmark of malignant diseases, is highly associated with an aggressive tumor phenotype and therapeutic resistance [1]. A variety of invasive and non-invasive methods have been developed to detect and monitor spatial and temporal hypoxia in tumors, including biological markers and non-invasive imaging techniques [2]. Positron emission tomography (PET) imaging has been investigated for imaging tumor hypoxia using a variety of tracers, including 18F-fluoroazomycinarabino-furanoside (18F-FMISO), 18F-fluoroazomycinarabinofuranoside (18F-FAZA) and Cu (II)-diacetyl-(N4-methylthiosemicarbazone (Cu-ATSM). However, most PET hypoxia tracers show unfavourable results in liver hypoxia imaging. The limitations of these PET tracers include low imaging contrast resulting from their relatively high lipophilicity and slow clearance characteristics; slow accumulation in hypoxic tumors; measurement of predominantly chronic rather than acute hypoxia; and absolute uptake is not purely pO2-dependent being confounded by changes in vascular delivery and cellular reductase expression [3]. Currently, no imaging modalities have been recommended for imaging liver tumor hypoxia in clinical practice.

Hypoxia in solid tumors is mainly due to increased metabolic demands of tumor cells surpassing the delivery of oxygen. Several studies have shown that a mismatch between blood supply and metabolism leads to aggressive tumor behaviour and more therapeutic resistance [46]. Moreover, there is evidence that a low-flow and high-metabolism tumor phenotype was correlated with high expression of hypoxia-inducible factor-1α (HIF-1α), which is an adaptive response to hypoxia [7]. We hypothesize that this mismatch between tumor blood flow and glucose metabolism would be significantly associated with the severity of tumor hypoxia. The increasing availability of hybrid PET- CT scanners nowadays may allow non-invasive measurements of tumor metabolism by 18F-FDG-PET and tumor perfusion by perfusion CT in the same imaging session. The aim of this study was to investigate the relationship between tumor perfusion and metabolism parameters as measured by PET-CT and tumor hypoxia, and determine which imaging biomarker better predicts tumor hypoxia in a liver tumor model.

Materials and methods

Twelve male New Zealand white rabbits each weighting 3.0–3.6 kg (Charles River Laboratories in Montreal, Quebec, Canada) were used in this study. Experiments were performed in compliance with Canadian Council of Animal Care guidelines and all experimental procedures were approved by the Animal Use Subcommittee at the University of Western Ontario.

Animal anesthesia and monitoring

The rabbit was feeding before all the studies. For each rabbit, anesthesia was induced by masking with 5% isoflurane. A marginal ear vein was catheterized and an endotracheal tube was inserted into the trachea using a laryngoscope. Anesthesia was maintained by ventilating with 2–5% isoflurane mixed with medical air at a rate of 20 breaths per minute. The animal's rectal temperature and end tidal carbon dioxide level (EtCO2) were monitored (Surgivet Advisor Vital Signs Monitor V9200, Smiths Medical, Dublin, USA). Heart rate (HR) and arterial oxygen saturation (SpO2) were continuously measured by pulse oximetry (MouseOx, Starr Life Science, Oakmont, USA). During the experimental period, animal’s rectal temperature was maintained between 38.5°C and 39.5°C with a heated water blanket. EtCO2 was maintained between 37–42 mmHg by adjusting the peak inspiratory pressure. 0.2 mL pancuronium bromide (Sandoz, Boucherville, Canada) was injected intravenously if breath-hold by turning off the ventilator was required.

Rabbit VX2 liver tumour model

A tumor derived from implanted VX2 cells was removed from the thigh of a donor rabbit. The harvested tumor was homogenized and suspended in Hanks balanced salt solution (Sigma-Aldrich Canada, Oakville, Ontario, Canada). After anesthesia, the abdominal area of a rabbit was shaved, and 0.15–0.2 mL of the tumor suspension from the donor rabbit was directly injected into the left liver lobe of the rabbit under CT guidance to avoid large vessels. Tumor growth was monitored every 4 to 7 days after tumor implantation by contrast enhanced helical CT scanning. This scan was performed under breath hold by turning off the ventilator and after a delay of 8s from injection of 6 mL of 200 mg iodine per milliliter contrast agent (iohexol, GE healthcare, Waukesha, USA) at a rate of 1 mL per second into an ear vein. The thorax and abdomen of the rabbit were scanned with a clinical CT scanner (HD 750, GE Healthcare, Waukesha, USA) using the following technique: 60 mA, 80 kVp, 1 second gantry rotation, 5 mm slice thickness and a pitch of 0.985. When the implanted tumor had reached approximately 10–20 mm in diameter (mean diameter 16 mm ± 5, maximum diameter 23mm), integrated 18F-FDG PET / perfusion CT scans were performed and tumor oxygenation was measured. If the rabbit lost weight more than 20% or massive effusion was observed in the thoracic or abdominal cavity, the animal would be euthanized with an overdose of sodium pentobarbital. In this study, no animal died prior to being euthanized.

Integrated perfusion CT / 18F-FDG PET

Integrated Perfusion CT/18F-FDG PET was performed using a hybrid 64-slice CT and PET scanner system (Discovery LS, GE Healthcare, Waukesha, USA). Imaging started with intravenous injection of 53.1 ± 3.8 MBq 18F-FDG through a 24G ear vein cannula. A contrast enhanced helical CT scan without breath hold was then performed to monitor the tumor size and determine the scan limits of the subsequent perfusion study. Ten minutes after the helical scan, a perfusion CT study was acquired. Five mL of 200 mg iodine per mL contrast was injected at a rate of 1 mL/sec into an ear vein at the start of the two-phase perfusion CT examination. In the first phase, the ventilator was turned off for 30 seconds; eight 2.5-mm thick sections covering the tumor were scanned continuously without breath motion. In the second phase, the ventilator was turned back on and the animal was scanned continuously for 4s (the ventilation cycle was 3s long) without breath hold every 10 seconds for 12 additional acquisitions. The scan parameters were 120 kVp, 60 mA, 1 second gantry rotation, 2.5 mm slice thickness, and total acquisition time was 150 s.

Sixty minutes after injection of the 18F-FDG dose and nearly 30 minutes after the perfusion CT study, PET acquisition was performed in static three-dimensional mode at two contiguous bed positions including the perfusion CT scan range, 5 minutes per bed position for a total of 10 minutes. Acquired PET data after correction for attenuation and random coincidence was reconstructed into 128 × 128 images. A total of eighty-three 4.25-mm-thick images were available covering the entire thorax and abdomen for each PET study. Prior to the PET scan, one helical CT scan with the same axial range as the PET scan was acquired with the following parameters: 140kVp, 80mA, 1 second per rotation and a pitch of 1.25. CT images were reconstructed into 5-mm-thick sections at 4.25-mm intervals for use in the attenuation correction of acquired PET data.

All imaging examinations were completed in 70.9 ± 8.1 minutes after intravenous injection of 18F-FDG.

pO2 measurement

After the perfusion CT study was completed and before the 18F-FDG PET study, tumor oxygenation was measured using the Oxylite system (Oxford Optronix, Abingdon, United Kingdom) with a large area probe (8 mm2 sampling area). The probe was introduced into the tumor through a 20G catheter and advanced under CT guidance such that the tip of the oxygen probe was beyond the tumor in the adjacent normal liver tissue. The CT images acquired were used for registration with perfusion maps. Tissue oxygen partial pressure (pO2) was sampled by withdrawing the probe at 5.0 mm intervals. At each location, pO2 was recorded when the reading was stable for more than 1 minute and fluctuation range was less than 1 mmHg. Three to six measurements were taken along the needle track in each tumor. Animals were kept under anesthesia, and EtCO2 and rectal temperature were continuously monitored and maintained within normal limits during the pO2 measurement period.

Perfusion parameters and PET standardized uptake value

The perfusion parameter maps were generated using CT perfusion software based on Lawrence-Lee model (GE Healthcare). Dual blood supply of liver was taken into consideration and the measurement of blood flow has been validated against the gold standard radioactive microsphere in the same liver tumor model. Details were described in previous publications [8, 9]. Image registration between the perfusion maps and axial CT acquired during oxygen probe insertion was performed using free open-source software—3D slicer 4.4 (http://www.slicer.org). Several circular regions of interests (ROIs), each of 5 mm diameter and at 5 mm interval, were used to measure perfusion measurements including blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) along the oxygen sampling track. The 18F-FDG uptake within each ROI was determined from the automatically registered PET images (with respect to the perfusion CT maps) with PET-CT review software on an Advantage Window workstation (GE Healthcare). Standardized uptake value (SUV) was calculated by the following formula: SUV = mean ROI activity × body weight / Injected activity. The flow—metabolism ratio (FMR) was calculated as BF divided by SUV.

Histopathological examination

Pimonidazole hydrochloride (Hypoxyprobe, Burlington, MA, USA) dissolved in 0.9% saline was administered intravenously at a dosage of 60 mg/kg one hour before sacrifice with an overdose of potassium chloride. The liver was excised and cut into 5-mm-thick sections in an orientation matching the CT axial images. The central 5-mm-thick section embedding the oxygen sampling track was fixed in 10% neutral buffered formalin for 24–48 hours and then phosphate buffered saline for 12 hours before being embedded in parafin. One tumor sample was excluded due to inappropriate sample preparation; therefore, eleven samples were included in the subsequent histopathological examination.

The paraffin-embedded tissue blocks were sectioned at 5 μm and deparaffinised for HE staining. For pimonidazole staining, the 5 μm sections were placed in 3% H2O2 for 10 minutes to block peroxidase activity. The sections were incubated with the FITC-labeled anti-pimonidazole antibody (Hypoxyprobe, Burlington, MA, USA) diluted 1:1000 overnight at 4°C and with secondary antibody (anti-mouse IgG, ImmPRESS kit, Vector Laboratories, Switzerland) for 40 minutes at room temperature before DAB Peroxidase Substrate Kit (3,3’—diamiobenzidine, Vector Laboratories, Switzerland) was applied.

Semi-quantitative analysis of pimonidazole staining

All stained sections were scanned and digitized at a spatial resolution of 0.5 μm / pixel using TissuescopeTM 4000 scanner (Huron Technologies, Waterloo, Canada). The pimonidazole images were subsampled to the same resolution as the CT image (0.5 mm / pixel) before co-registration with the latter. Anatomic landmarks, such as tumor shape / edge, necrotic area, liver margin, blood vessel, and probe track were used for the registration. The same set of circular ROIs 5 mm in diameter and at 5 mm intervals were superimposed on each type of co-registered images: perfusion CT maps, PET SUV map, and pimonidazole stained sections (Fig 1). Pimonidazole stained area was identified and measured by setting a threshold determined with the Shanbhag algorithm [10] as implemented in ImageJ (NIH, Bethesda, MD, USA). For semi-quantitative analysis of hypoxia in each circular ROI, pimonidazole staining was scored based on the percentage of positively stained area and scored as follows: 1, 0–5%; 2, 5–15%; 3, 15–30%; 4, >30%.

thumbnail
Fig 1. Co-registration of blood flow map from perfusion CT, PET SUV image, and pimonidazole stained section of a liver tumor.

Tumor shape/edge (blue outline), necrotic area (yellow outline) and needle track (red arrow) were well-matched among the different types of images. A, Axial CT image showing the position of the oxygen probe. B, PET SUV image superimposed on CT image shown in A. C, blood flow map from perfusion CT. D, a well-matched pimonidazole stained image. E, Thresholded image of D and the circular regions along the needle track as in C.

https://doi.org/10.1371/journal.pone.0173016.g001

Statistical analysis

All data are reported as mean ± standard deviation. Pearson Correlation was used to determine the associations between BF, BV, MTT, PS, SUV, and FMR and pO2 or pimonidazole staining score as well as that between pO2 and pimonidazole staining score (SPSS for Windows, version 17.0; SPSS, Chicago, USA). Tumor regions were also subdivided into hypoxia or non-hypoxia groups according to pO2 (less or more than 10 mmHg), and the flow—metabolism ratio of each group was compared using the Mann—Whitney U test. A two-tailed P value of less than .05 was considered to indicate a statistically significant difference.

Results

pO2 measurements and pimonidazole staining

Tumor oxygenation measured by Oxylite showed a wide distribution ranging from 0 mmHg to 40.9 mmHg. The mean pO2 value in the tumor region was 9.07 ± 10.09 mmHg. In contrast, pO2 level in adjacent normal liver region was 27.02 ± 18.60 mmHg.

Pimonidazole staining was evident in all rabbit tumors. Positive pimonidazole staining was not only seen in tumors but also in normal liver tissues [11]. However, strong staining was only observed in tumor area peripheral to the necrotic zone. Statistically significant negative correlation was found between pimonidazole staining score and pO2 (r = -0.56, P < 0.001) (Fig 2).

thumbnail
Fig 2. Correlation between tumor pO2 and pimonidazole staining score.

Data from 11 rabbit VX2 liver tumors.

https://doi.org/10.1371/journal.pone.0173016.g002

Correlation of perfusion parameters, glucose metabolism and pO2

As shown in Table 1, there were no significant correlations between tumor BF, MTT, PS, 18F-FDG metabolism (SUV) and pO2 level. Significant correlations were found between BV and pO2 (r = 0.43, P = 0.004) and between SUV and pO2 level (r = -0.39, P = 0.007). Conversely, there was stronger correlation between FMR and tumor oxygenation (r = 0.56, P < 0.001) (Fig 3). According to pO2 level, tumor regions were subdivided into hypoxic (pO2 < 10mmHg) and non-hypoxic (pO2 ≥ 10mmHg), the mean value of FMR was 25.64 ± 16.40 in hypoxic regions, which was significantly lower than 45.98 ± 30.62 found in non-hypoxic regions (P = 0.027).

thumbnail
Table 1. Spearman rank correlation between perfusion CT parameters and pO2 or pimonidazole staining.

https://doi.org/10.1371/journal.pone.0173016.t001

thumbnail
Fig 3. Correlation between tumor pO2 and FMR.

Data from 12 rabbit VX2 liver tumors.

https://doi.org/10.1371/journal.pone.0173016.g003

Correlation of perfusion parameters, glucose metabolism and pimonidazole staining

No correlations were observed between BF, BV, MTT, PS, and SUV and pimonidazole staining score (Table 1), but negative correlation was found between FMR and pimonidazole score (r = -0.39, P = 0.031) (Fig 4).

thumbnail
Fig 4. Correlation between pimonidazole staining score and FMR.

Data from 11 rabbit VX2 liver tumors.

https://doi.org/10.1371/journal.pone.0173016.g004

Discussion

The mismatch of blood flow and metabolism in tumors as a consequence of the Warburg effect has been comprehensively reviewed by Miles and Williams [12]. Their review showed that this mismatch has been proven in a variety of tumors including brain, breast, lung, liver, colon, and head and neck. Futhermore, a number of clinical studies have shown that the mismatch is associated with tumor aggressiveness and poor survival [6, 13, 14]. Goh et al [7] using immunohistochemical staining of excised colorectal tumor samples show that low FMR was inversely correlated with high vascular endothelial growth factor (VEGF) or hypoxia-inducible factor-1 expression, suggesting that FMR may be related to hypoxia. However, as far as we know, there has been no direct comparison of FMR against pO2 measurement or pimonidazole staining, both are considered ‘gold’ standards for hypoxia assessment.

Currently, a variety of imaging biomarkers are under investigation for tumor hypoxia detection. Our data suggested FMR by integrated 18F-FDG PET / perfusion CT may be a better biomarker of hypoxia than single perfusion CT parameter (BF, BV, MTT, PS, and SUV) or SUV value of 18F-FDG.

In this study, only a weak correlation was found between 18F-FDG SUV and tumor oxygenation status (pO2). While 18F-FDG-PET has been used extensively in oncology imaging since several decades ago, the question whether 18F-FDG was a good surrogate for tumor hypoxia has continued to be debated. Both pre-clinical and clinical studies have investigated the relationship of SUV values with hypoxia markers and conflicting results were obtained [1517]. Based on recent data, it appears that correlation between hypoxia and 18F-FDG accumulation is highly tumor type-dependent. The degree to which 18F-FDG uptake correlates with the severity of hypoxia may only occur in tumors with less-pronounced Warburg effect [18] or when HIF-1 activation is mainly hypoxia-driven [19]. On the other hand, although tumor oxygen delivery is dominated by blood flow, few studies have shown the correlation of perfusion CT parameters with immunohistochemical markers of hypoxia [20]. In our study, BV is the only perfusion parameter correlated with pO2. In the case of pimonidazole staining, it was not correlated to either perfusion CT parameters or 18F-FDG uptake. In normal tissue, auto-regulatory mechanisms ensures glucose metabolism and BF are tightly coupled, which is not necessarily so with tumor. The deranged vascular supply and energy metabolism within tumor cells result in inefficient oxygen delivery and use of energy substrates, a hallmark of flow metabolism mismatch. Our data suggest that this mismatch, especially in regions with low perfusion, high metabolism, is highly correlated to hypoxia based on pO2 measurement as well as pimonidazole staining. Thus, the FMR may be a helpful predictor for therapeutic resistance from hypoxia.

Different from previous published papers [21, 22], a statistically significant correlation between pO2 and pimonidazole was found. The lack of correlation in prior studies could be due to the use of a small diameter (25–30μm) oxygen needle (probe) to measure oxygen tension at a ‘single’ point in time, providing an average reading from a small ensemble of viable or necrotic cells but pimonidazole adducts, on the other hand, accumulate only in viable cells. In our study, a larger area probe (8 mm2 sampling area vs 19.6 mm2 ROIs used in the analysis of pimonidazole stained section) was employed, accordingly, the sampling volume of oxygen measurement and pimonidazole staining were more similar, reducing the inherent error in the mismatch of sampling volumes. Second, using CT guidance, the location of the oxygen probe were closely matched to the pimonidazole stained sections as well as the 18F-FDG SUV image (see Fig 1). Third, the number of oxygen measurement in each tumor was limited to five only to achieve a more precise measurement by averaging over a longer sampling period. The above refinements in our experimental technique likely contribute to the significant negative correlation between pimonidazole staining score and pO2 in our study.

As the normal liver is supplied mainly by partially deoxygenated blood from the portal vein, it is hypoxic relative to other tissues supplied by fully oxygenated blood. This explains our observation of pimonidazole staining in normal liver which is corroborated by other reported studies [11]. It raises the concern that hypoxia PET tracers, such as [18F] FMISO, could bind to normal liver and interfere with hypoxic imaging in the tumor.

Fig 3 shows that a number of tumor regions had high FMR despite the oxygen tension was close to zero. A possible explanation was that the perfusion CT study was performed before the oxygen probe insertion while the 18F-FDG SUV measurement was obtained after. As such, due to unavoidable tissue damage during the oxygen probe insertion, the SUV measurements of some tumor regions could be underestimated leading to an erroneously high FMR.

Several limitations of our study need to be addressed. First, as tumor hypoxia can exist both in macroscopic and microscopic scale [23], the spatial resolution of clinical PET (~ 5mm) would limit it to detecting only the macroscopic distribution of hypoxia. Second, the matching of pimonidazole stained sections to imaging (perfusion CT maps and 18F-FDG SUV maps) may not be perfect contributing to some of the variability in our results. Third, only one 5 μm tissue slice through (or adjacent to) the oxygen needle track was used in the analysis to simplify the analysis, which may not represent the global distribution of hypoxia. Fourth, as we discussed previous, hypoxia is highly tumor-dependent. Many factors, including tumor type, size, stage, disease site, would influence the final results. Therefore, similar investigations on different tumor types from different cell lines are needed to confirm the existence of a relationship between hypoxia and FMR. Lastly, the effective dose from the perfusion CT is relatively high ~21.3 mSv. However, this can be decreased by half if each of the ten 2nd phase scans is reduced in duration from 4 to 1 s and then image registration is used to align these 2nd phase images with those of the first phase [24]. Furthermore, newer compressed sensing reconstruction technique with spare view acquisition [25] can further reduce the effective dose by at least 3 times resulting in a more acceptable dose of 3.5 mSv.

Conclusion

Our study contributes to the understanding of the relationship between functional imaging parameters and tumor hypoxia. Given the increasing availability of PET and high-end CT, FMR may be a promising image biomarker to monitor for tumor regional hypoxia, which need further investigation in various tumor types and in clinical practice.

Acknowledgments

The authors would like to thank Dr. Kazuhiro Yasufuku in the Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Canada, for the generous gift of VX2 cells. The authors would also thank Dr. Paula Foster and her lab members in the Department of Medical Biophysics, University of Western Ontario, London, Canada, for their assistance in immunohistochemical staining.

Author Contributions

  1. Conceptualization: YW ES TYL.
  2. Data curation: YW ES TYL.
  3. Formal analysis: YW ES TYL.
  4. Funding acquisition: TYL.
  5. Investigation: YW ES LD JH LM CC TYL.
  6. Methodology: YW ES LD JH LM CC TYL.
  7. Project administration: YW ES LD JH LM CC TYL.
  8. Resources: YW ES LD JH LM CC TYL.
  9. Supervision: ES TYL.
  10. Validation: YW ES TYL.
  11. Visualization: YW ES TYL.
  12. Writing – original draft: YW ES TYL.
  13. Writing – review & editing: YW TYL.

References

  1. 1. Wilson WR, Hay MP (2011) Targeting hypoxia in cancer therapy. Nat Rev Cancer 11:393–410. pmid:21606941
  2. 2. Olive PL, Banáth JP, Aquino-Parsons C (2001) Measuring hypoxia in solid tumours—is there a gold standard? Acta Oncol 40:917–923. pmid:11845955
  3. 3. Fleming IN, Manavaki R, Blower PJ, West C, Williams KJ, Harris AL, et al (2015) Imaging tumour hypoxia with positron emission tomography. Br J Cancer 112:238–250. pmid:25514380
  4. 4. Mankoff DA, Dunnwald LK, Gralow JR, Ellis GK, Charlop A, Lawton TJ, et al (2002) Blood flow and metabolism in locally advanced breast cancer: relationship to response to therapy. J Nucl Med 43:500–509. pmid:11937594
  5. 5. Mankoff DA, Dunnwald LK, Partridge SC, Specht JM (2009) Blood flow-metabolism mismatch: good for the tumor, bad for the patient. Clin Cancer Res 15:5294–5296. pmid:19706819
  6. 6. Komar G, Kauhanen S, Liukko K, Seppänen M, Kajander S, Ovaska J, et al (2009) Decreased blood flow with increased metabolic activity: a novel sign of pancreatic tumor aggressiveness. Clin Cancer Res 15:5511–5517. pmid:19706808
  7. 7. Goh V, Engledow A, Rodriguez-Justo M, Shastry M, Peck J, Blackman G, et al (2012) The flow-metabolic phenotype of primary colorectal cancer: assessment by integrated 18F-FDG PET/perfusion CT with histopathologic correlation. J Nucl Med 53:687–692. pmid:22454485
  8. 8. Stewart EE, Chen X, Hadway J, Lee TY (2006) Correlation between hepatic tumor blood flow and glucose utilization in a rabbit liver tumor model. Radiology 239:740–750. pmid:16621929
  9. 9. Stewart EE, Chen X, Hadway J, Lee TY (2008) Hepatic perfusion in a tumor model using DCE-CT: an accuracy and precision study. Phys Med Biol 53:4249–4267. pmid:18653923
  10. 10. Shanbhag A.G. (1994) Utilization of information measure as a means of image thresholding. CVGIP: Graphical Models and Image Processing 56:414–419.
  11. 11. Arteel GE, Thurman RG, Yates JM, Raleigh JA (1995) Evidence that hypoxia markers detect oxygen gradients in liver: pimonidazole and retrograde perfusion of rat liver. Br J Cancer 72:889–895. pmid:7547236
  12. 12. Miles KA, Williams RE (2008) Warburg revisited: imaging tumour blood flow and metabolism. Cancer Imaging 8: 81–86. pmid:18390391
  13. 13. Dunnwald LK, Gralow JR, Ellis GK, Livingston RB, Linden HM, Specht JM, et al (2008) Tumor metabolism and blood flow changes by positron emission tomography: relation to survival in patients treated with neoadjuvant chemotherapy for locally advanced breast cancer. J Clin Oncol 26:4449–4457. pmid:18626006
  14. 14. Semple SI, Gilbert FJ, Redpath TW, Staff RT, Ahearn TS, Welch AE, et al (2004) The relationship between vascular and metabolic characteristics of primary breast tumours. Eur Radiol 14:2038–2045. pmid:15316743
  15. 15. Christian N, Deheneffe S, Bol A, De Bast M, Labar D, Lee JA, et al (2010) Is (18) F-FDG a surrogate tracer to measure tumor hypoxia? Comparison with the hypoxic tracer (14) C-EF3 in animal tumor models. Radiother Oncol 97:183–188. pmid:20304513
  16. 16. Zimny M, Gagel B, DiMartino E, Hamacher K, Coenen HH, Westhofen M, et al (2006) FDG—a marker of tumour hypoxia? A comparison with [(18) F] fluoromisonidazole and pO2-polarography in metastatic head and neck cancer. Eur J Nucl Med Mol Imaging 33:1426–1431. pmid:16841141
  17. 17. Cherk MH, Foo SS, Poon AM, Knight SR, Murone C, Papenfuss AT, et al (2006) Lack of correlation of hypoxic cell fraction and angiogenesis with glucose metabolic rate in non-small cell lung cancer assessed by 18F-Fluoromisonidazole and 18F-FDG PET. J Nucl Med 47:1921–1926. pmid:17138734
  18. 18. Busk M, Horsman MR, Kristjansen PE, van der Kogel AJ, Bussink J, Overgaard J (2008) Aerobic glycolysis in cancers: implications for the usability of oxygenresponsive genes and fluorodeoxyglucose-PET as markers of tissue hypoxia. Int J Cancer 122:2726–2734. pmid:18351643
  19. 19. Dierckx RA, Van de Wiele C (2008) FDG uptake, a surrogate of tumour hypoxia? Eur J Nucl Med Mol Imaging 35:1544–1549. pmid:18509637
  20. 20. Mandeville HC, Ng QS, Daley FM, Barber PR, Pierce G, Finch J, et al (2012) Operable non-small cell lung cancer: correlation of volumetric helical dynamic contrast-enhanced CT parameters with immunohistochemical markers of tumor hypoxia. Radiology 264:581–589. pmid:22700554
  21. 21. Nordsmark M, Loncaster J, Chou SC, Havsteen H, Lindegaard JC, Davidson SE, et al (2001) Invasive oxygen measurements and pimonidazole labeling in human cervix carcinoma. Int J Radiat Oncol Biol Phys 49:581–586. pmid:11173158
  22. 22. Jankovic B, Aquino-Parsons C, Raleigh JA, Raleigh JA, Stanbridge EJ, Durand RE, et al (2006) Comparison between pimonidazole binding, oxygen electrode measurements, and expression of endogenous hypoxia markers in cancer of the uterine cervix. Cytometry B Clin Cytom 70:45–55. pmid:16456867
  23. 23. Busk M, Horsman MR, Jakobsen S, Hansen KV, Bussink J, van der Kogel A, et al (2009) Can hypoxia-PET map hypoxic cell density heterogeneity accurately in an animal tumor model at a clinically obtainable image contrast? Radiother Oncol 92:429–436. pmid:19729214
  24. 24. Jensen NK, Lock M, Fisher B, Kozak R, Chen X, Chen J, et al (2013) Prediction and reduction of motion artifacts in free-breathing dynamic contrast enhanced CT perfusion imaging of primary and metastatic intrahepatic tumors. Acad Radiol 20:414–422. pmid:23498981
  25. 25. Enjilela E, Lee T-Y, Hsieh J, Branch K, Glenny Robb, So A (2015) Compressed sensing-based computed tomography perfusion imaging: Preliminary study. Abstract SSJ22-03 RSNA 2015. http://rsna2015.rsna.org/program/index.cfm.