Characterizing the Indoor-Outdoor Relationship of Fine Particulate Matter in Non-Heating Season for Urban Residences in Beijing

  • Lihui Huang ,

    hlhfustar@gmail.com

    Affiliations Key Laboratory of Subsurface Hydrology and Ecological Effects in Arid Region, Ministry of Education, School of Environmental Science and Engineering, Chang’an University, Xi’an, 710054, China, Institute of Built Environment, Department of Building Science, Tsinghua University, Beijing, 100084, China

  • Zhongnan Pu,

    Affiliation Institute of Built Environment, Department of Building Science, Tsinghua University, Beijing, 100084, China

  • Mu Li,

    Affiliation Institute of Built Environment, Department of Building Science, Tsinghua University, Beijing, 100084, China

  • Jan Sundell

    Affiliation Institute of Built Environment, Department of Building Science, Tsinghua University, Beijing, 100084, China

Abstract

Objective

Ambient fine particulate matter (PM2.5) pollution is currently a major public health concern in Chinese urban areas. However, PM2.5 exposure primarily occurs indoors. Given such, we conducted this study to characterize the indoor-outdoor relationship of PM2.5 mass concentrations for urban residences in Beijing.

Methods

In this study, 24-h real-time indoor and ambient PM2.5 mass concentrations were concurrently collected for 41 urban residences in the non-heating season. The diurnal variation of pollutant concentrations was characterized. Pearson correlation analysis was used to examine the correlation between indoor and ambient PM2.5 mass concentrations. Regression analysis with ordinary least square was employed to characterize the influences of a variety of factors on PM2.5 mass concentration.

Results

Hourly ambient PM2.5 mass concentrations were 3–280 μg/m3 with a median of 58 μg/m3, and hourly indoor counterpart were 4–193 μg/m3 with a median of 34 μg/m3. The median indoor/ambient ratio of PM2.5 mass concentration was 0.62. The diurnal variation of residential indoor and ambient PM2.5 mass concentrations tracked with each other well. Strong correlation was found between indoor and ambient PM2.5 mass concentrations on the community basis (coefficients: r≥0.90, p<0.0001), and the ambient data explained ≥84% variance of the indoor data. Regression analysis suggested that the variables, such as traffic conditions, indoor smoking activities, indoor cleaning activities, indoor plants and number of occupants, had significant influences on the indoor PM2.5 mass concentrations.

Conclusions

PM2.5 of ambient origin made dominant contribution to residential indoor PM2.5 exposure in the non-heating season under the high ambient fine particle pollution condition. Nonetheless, the large inter-residence variability of infiltration factor of ambient PM2.5 raised the concern of exposure misclassification when using ambient PM2.5 mass concentrations as exposure surrogates. PM2.5 of indoor origin still had minor influence on indoor PM2.5 mass concentrations, particularly at 11:00–13:00 and 22:00–0:00. The predictive models suggested that particles from traffic emission, secondary aerosols, particles from indoor smoking, resuspended particles due to indoor cleaning and particles related to indoor plants contributed to indoor PM2.5 mass concentrations in this study. Real-time ventilation measurements and improvement of questionnaire design to involve more variables subject to built environment were recommended to enhance the performance of the predictive models.

Introduction

The rapid urbanization and industrialization result in the recent nationwide ambient fine particle pollution (haze episodes) in Chinese urban areas. Fine particulate matter (PM2.5) is a complicated mixture of solid and liquid particles that vary in number, size, shape, surface area, chemical composition, solubility and origin [1, 2]. Exposure to toxic components in ambient PM2.5 is associated with a wide spectrum of adverse respiratory and cardiovascular health effects[312], and even with low birth weight and increased risk of preterm birth [13, 14]. Therefore, fine particle pollution in ambient air is currently a major public health concern in China, and is driving increasing research interest [12, 1517].

Chinese urban residents spend nearly 90% of lifetime indoors, and of that, 70% is in residential indoor microenvironments[18]. As a result, exposure to airborne PM2.5 primarily occurs indoors. Ambient PM2.5 penetrate indoors through the ventilation system, the building envelope and cracks [1921]. The outdoor-indoor transit of ambient particles can alter PM chemical and physical properties such as mass concentrations, size-distribution and composition [20, 2224]. For example, the fraction of ambient PM2.5 that can penetrate indoors and remain suspended (defined as infiltration factor, Finf) largely vary from 35% to 95% in the literature[19, 2532]. Particles in the accumulation mode have higher Finf values than particles of other size bins [24, 26]. On the other hand, particles generated by indoor sources may also significantly contribute to indoor PM2.5. The primary indoor PM2.5 sources include environmental tobacco smoke (ETS), home cleaning and heat/combustion activities[21, 33]; whereas the secondary sources include, but not limited to, ozonolysis of unsaturated hydrocarbons and oxidation of aromatics [30, 34, 35].

Due to the properties alteration during infiltration process and the presence of indoor sources, the diurnal variation pattern of indoor and outdoor PM2.5 concentrations may significantly differ. The ratio of indoor to outdoor PM2.5 mass concentrations (defined as I/A in this article) can be greater than unity sometimes. It is thus uncertain if central-site PM2.5 mass concentrations are good surrogates of exposure to ambient PM2.5. Given such, it is necessary to characterize the relationship between indoor and outdoor PM2.5 concentrations as part of fine particle exposure assessment, which has not been well studied in China.

The objective of this study is to characterize the indoor-ambient relationship of PM2.5 mass concentrations in non-heating season for urban residences in Beijing. We concurrently collected real-time indoor and outdoor PM2.5 mass concentrations for 41 urban residences in Beijing in the non-heating season. Infiltration factor of ambient PM2.5 and its determinants have been discussed in a companion paper. In this article, we compared the diurnal variation of indoor and ambient PM2.5 mass concentrations as well as I/A. Further, we explored the predictors of indoor PM2.5, which suggested the likely indoor PM2.5 sources in the tested urban residences during the monitoring period. The results and the mechanisms driving the observations are discussed in this article.

Materials and Methods

Fudan University’s ethical review board approved the study protocol (IRB00002408 & FWA00002399). The field tests were conducted based upon permissions from the property owners. A written consent was obtained from the participants prior to the field visit. We also implemented sampling at several outdoor sites in this study, in order to compare the measurements of our light-scattering devices to those of Chinese National Environmental Quality Monitoring (EQM). Permissions were obtained from Citic Group (the owner of the site close to Agriculture Exhibition Center EQM station), Department of Building Science, Tsinghua University (the owner of the site close to Wanliu EQM station), and the private land owners of other sites.

Buildings sampled

The families that participated in this study were from a large cohort, which was recruited for a public health research project. The randomly selected cohort consisted of families in Beijing having 1–8 years old children. We contacted the parents in each family via telephone, informed them the research objective, and recruited the families that were willing to join in. Forty-one families participated in this study. These residences are located in 6 districts in Beijing: 17 in Haidian, 5 in Xicheng, 3 in Fengtai, 1 in Shijingshan, 1 in Changping and 14 in Chaoyang. Questionnaires were administrated to the occupants during each visit to gather demographic and social-economic information, building characteristics, lifestyle information and time-activity pattern.

The dwellings tested in this study are relatively young (~50% less than 10-yr old). The occupants were also the property owners in 89% of the tested dwellings. All residences are multistory (≤7 stories, 39% of residences) or high-rise type (> 7 stories, 61% of residences). Mechanical ventilation is employed by only 1 residence, and others ventilate the indoor spaces through opening windows. Radiators are used for heating in 91% of the dwellings, whereas floor heating is used in the others. Central air conditioning is used for cooling in 2 dwellings, whereas split type air conditioning is used for cooling in the others. According to the time-activity records, ~60% families turned on air conditioner (AC) for 1–3 hours during the monitoring periods, and the windows were open when AC was not in operation.

Variables subject to building characteristics and human behavior that are associated with indoor PM2.5 sources were of particular interests in the subsequent analysis. These variables included the type of traffic route around residence, distance to the road, indoor smoking activities during the monitoring period, cooking activities during the monitoring period, frequency of floor cleaning, floor cleaning method, frequency of furniture cleaning, indoor plants and number of occupants. Traffic emission is one of the important sources of indoor PM2.5 [23, 36]. Therefore, variables subject to traffic conditions may be important predictors of indoor PM2.5. Three types of traffic routes can be found proximate to the tested residences: expressways or arterial roads (ring roads of Beijing), local highways and quiet streets (Fig 1). The distances between each residence and the proximate road were measured and grouped into 4 quartiles (1st quartile: ≤ 193 m, 2nd quartile: 194–270 m, 3rd quartile: 271–425 m, 4th quartile: >425 m). Indoor smoking activities occurred in 23% of the tested dwellings during the monitoring periods (Fig 1). Cleaning activities can lead to resuspension of particles, which are also important sources of indoor PM2.5 [37, 38]. Thus, we collected the information of indoor cleaning, which included frequency of floor cleaning, method of floor cleaning and frequency of furniture cleaning (as shown in Fig 1). Cooking is another important source of indoor PM2.5, particularly ultrafine particles [39]. The cooking times during the monitoring periods were presented in Fig 1. Indoor plants can be another predictor of indoor PM2.5, given resuspension of soil particles and submicron particles generation via biogenic VOCs-ozone reactions [35]. Fig 1 presents the information of indoor plants in the tested dwellings. In addition, we considered the variable, number of occupants, given that human activities indoors are associated with particle generation. The maximum occupant number was 7, whereas the minimum was 0. The dwellings with 2 to 6 occupants accounted for 6%, 33%, 14%, 28% and 11% of total residences, respectively.

thumbnail
Fig 1. The information of variables subject to building characteristics and human behavior.

https://doi.org/10.1371/journal.pone.0138559.g001

Field measurements

The field visits were implemented from July 1st to September 8th, 2013. A light-scattering SidePAKTM personal aerosol monitor (AM510, TSI Inc.) was deployed at a height of 1.5 m (breathing zone) in the living room of each residence to collect the hourly real-time indoor PM2.5 mass concentrations for consecutive 24 hours. The 24-h sampling period is frequently employed in exposure measurement and assessment, given that the data can reflect the daily average exposure levels of pollutant concentrations[40, 41]. As part of the quality assurance and quality control (QAQC) procedures, the photometers were calibrated every month against gravimetric measurements. Additionally, the standard deviation (SD) of the readings obtained by the collocated three photometers was 3.9±1.4%, which was evaluated in the laboratory prior to the field visits.

Due to constraints on the placement of monitors outdoors and availability of power, we did not collect concurrent real-time residential outdoor PM2.5 mass concentrations using the above devices, but obtained the real-time ambient PM2.5 mass concentrations during the monitoring periods from the Chinese National Environmental Quality Monitoring (EQM) Stations that were closest to each residences. These stations served for central-site fixed monitoring in our study. TEOM 1405F (Thermo Fisher Scientific Inc., MA, US) are employed at each EQM station to measure ambient PM2.5 mass concentrations. These instruments are routinely calibrated against gravimetric measurements. The distances between each residence and the closest monitoring stations are presented in Table A in the S1 File. We were concerned of the potential errors when using central-site outdoor PM2.5 mass concentrations as the surrogate of residential outdoor counterpart, despite the fact that extensive studies have suggested ambient fixed site monitoring to be reasonable surrogates of residential outdoor monitoring with respective to PM2.5 [42, 43]. To assess this uncertainty, we measured PM2.5 mass concentrations using the photometers at outdoor sites where the devices can be securely placed and there was power supply. The test sites had variable distances to the closest EQM stations. We compared the data obtained by the photometers to those provided by the closest EQM stations. As shown in Table B in S1 File, strong Pearson correlation was found (coefficient: 0.86–0.95), and the differences between the two measurements did not significantly differ from zero when the distances were within either 5.5 or 8 km (p>0.50, paired sample t-test). Note: the distances between 76% of the residences and the nearest EPA stations are within 5.5 km, while the distances for the remaining residences are within 7.0 km (Table A in S1 File). The results indicated that it was reasonable to use ambient fixed site monitoring as the surrogate of residential outdoor monitoring with respective to PM2.5 in our study.

We also collected the ambient criteria air pollutants (i.e. O3, NO2 and SO2) concentration data and meteorological data in this study. The hourly real-time concentrations of O3, NO2 and SO2 in ambient air were provided by the EQM stations that are closest to each residence. Daily average outdoor meteorological data were provided by China Meteorological Data Sharing Service System. Real-time indoor temperature and RH values were recorded by Telaire 7001 monitor (Telaire Inc., USA), which was connected to a HOBO U12 data logger (Onset, USA) for data logging.

Data analysis

Descriptive statistical analyses were conducted for ambient and indoor PM2.5 mass concentrations, I/A, ambient criteria air pollutants concentrations and meteorological data. A sampling day (24-hour) was divided into 4 sessions: morning (06:00–12:00), afternoon (12:00–18:00), evening (18:00–0:00) and night (0:00–6:00). The diurnal variation of indoor and ambient PM2.5 mass concentrations, I/A and criteria air pollutant concentrations were characterized. Due to the large day-to-day variability of pollutant concentrations, the original real-time data obtained in each residence were normalized prior to the diurnal variation characterization. The normalization procedure was as follows: the 24-h average values were set as the reference values with respect to each residence, and the hourly values were obtained by dividing the original hourly data by the 24-h average values.

The associations between indoor and ambient PM2.5 mass concentrations were examined using Pearson correlation analysis and regression analysis with ordinary least square (OLS) method, respectively. There were residences in which smoking activities occurred during the monitoring periods (smoking families). Given such, the data of all families were involved in the analyses first, and then the analyses were conducted again after excluding the data from the smoking families.

Predictive statistical models were built to characterize the variables that were associated with indoor and ambient PM2.5 mass concentrations. Regression analysis with OLS method was employed. The variables considered in the predictive model for ambient PM2.5 mass concentrations included the concentrations of ambient O3, NO2 and SO2. The variables considered in the predictive model for indoor PM2.5 mass concentrations included proximate traffic type, distance to road, indoor smoking activities, cooking activities, indoor cleaning activities, indoor plants and criteria air pollutant concentrations. The predictive models of indoor PM2.5 were built for all families and the non-smoking families, respectively. It is necessary to note that neither PM2.5 mass concentration data nor criteria air pollutant concentration data complied with normal or log-normal distribution (shown in Results section). However, it is still reasonable to apply the regression models to our data (N > 30) according to central limit theorem. The statistical analyses in this study were conducted with Statistical Analysis System (SAS v9.3, SAS Inc., Cary, NC). The significance level was 0.05 unless otherwise specified.

Results

Concentrations of pollutants

Ambient and indoor PM2.5.

The field sampling was implemented in the non-heating season. The mean ambient and indoor temperatures over the 24-h sampling period were in the range of 22.2–30.7°C and 25.6–33.2°C, respectively. The maximum and minimum hourly indoor temperatures were 47.2°C and 21.2°C, respectively. The hourly indoor RH was 19.1–79.9%, whereas the mean values over the 24-h sampling periods were 41.6–77.2% and 44–91% for indoor and ambient RH, respectively.

Descriptive statistics of ambient and indoor PM2.5 mass concentrations are summarized in Table 1. The maximum hourly ambient PM2.5 mass concentration in this study was 280 μg/m3, and the minimum was 3 μg/m3 (Table 1). The ambient concentrations over the 24-h sampling period were in the range of 15–165 μg/m3 with mean and median of 69 and 62 μg/m3, respectively (Table 1). The ambient PM2.5 concentration data did not comply with normal or log-normal distribution (p<0.001, Shapiro-Walk, shown in Figure A in S1 File). The means and medians of hourly and 24-h average ambient PM2.5 mass concentrations met the health guideline suggested by Chinese National Ambient Air Quality Standard (GB 3095–2012), 75 μg/m3. However, 38% of the hourly observations were still above the guideline.

thumbnail
Table 1. Descriptive statistics of the concentrations of pollutants.

https://doi.org/10.1371/journal.pone.0138559.t001

The maximum hourly indoor PM2.5 mass concentration in this study was 193 μg/m3, and the minimum was 4 μg/m3 (Table 1). The indoor concentrations over the 24-h sampling period were in the range of 9–119 μg/m3 with mean and median of 44 and 36 μg/m3, respectively (Table 1). Same as the ambient PM2.5 data, the indoor PM2.5 concentration data were neither normal nor log-normal distributed (p<0.001, Shapiro-Walk, shown in Figure B in S1 File).

The diurnal variation of ambient PM2.5 concentrations was shown in Fig 2. It can be discerned that: a) the concentrations started dropping after 8:00, and fell below the average values over the 24-h sampling period in the afternoon; b) there was noticeable concentration increase in the evening (19:00–23:00), and the concentrations reached the highest levels at night and in early morning (21:00–10:00); c) a concentration decrease was found between 3:00 and 5:00, and then a slight concentration increase can be discerned in 5:00–8:00. It is also found that the diurnal variation of residential indoor PM2.5 concentrations tracked the ambient counterpart well (Fig 2).

thumbnail
Fig 2. Diurnal variation of pollutant concentrations.

(Note: error bars in the Fig stand for standard deviation of the normalized pollutant concentrations).

https://doi.org/10.1371/journal.pone.0138559.g002

Criteria air pollutants.

In this study, the hourly ambient O3 concentrations were in the range of 1–285 μg/m3 with mean and median of 78 and 67 μg/m3, respectively (Table 1). The relatively high O3 episodes were expected, given the intense photochemical reactions in atmosphere in the summer. Of the hourly observations, 5% exceeded the health guideline suggested by GB 3095–2012 (200μg/m3). The hourly ambient NO2 concentrations were in the range of 8–143 μg/m3 with mean and median of 51 and 47 μg/m3, respectively (Table 1). No observations were above the health guideline of GB 3095–2012 (200μg/m3). Fig 2 shows the diurnal variation of ambient NO2 and O3 concentrations. Ambient O3 concentrations increased since 8:00 in the morning and reached the highest values at 15:00–18:00 in the afternoon. Contrary to O3, ambient NO2 concentrations started falling since 8:00 and reached the lowest values at 14:00–17:00. The reverse trends of ambient O3 and NO2 concentrations are expected, given that NO2 is the precursor of ground-level O3 in atmosphere and thus increasing O3 is accompanied by decreasing NO2 [44]. The hourly concentrations of ambient SO2 were 1–60 μg/m3 with mean and median of 7 and 6 μg/m3 (Table 1). Coal combustion for heating is the major source of ambient SO2 in Beijing. The sampling was conducted in the non-heating season, and thus the low ambient SO2 concentrations were within expectation. The criteria air pollutant concentration data did not comply with normal or log-normal distribution (p<0.001, Shapiro-Walk, shown in Figures C-E in S1 File).

Relationship between indoor and ambient PM2.5 mass concentrations

As shown in Table 2, there was significant and strong positive correlation (r≥0.90, p<0.0001) between indoor and ambient PM2.5 mass concentrations over the 24-h sampling period as well as the four sessions. The results indicated that the indoor and ambient PM2.5 mass concentrations in this study highly correlated with each other on the community basis. Excluding the smoking families was not found to weaken the strong correlation (Table 2). Nonetheless, the correlation coefficients varied by single residences. No significant correlation was observed for one residence, moderate correlation (0.5≤r<0.8) for 7 homes, and strong correlation (r≥0.8) for the other homes. Of the 8 residences, the occupants from only 2 dwellings reported smoking activities indoors during the monitoring periods. Smoking was thereby not the major cause for the weak correlation. The leading reasons, however, cannot be identified through the questionnaire in this study.

thumbnail
Table 2. Pearson correlation between indoor and ambient PM2.5 mass concentrations.

https://doi.org/10.1371/journal.pone.0138559.t002

The linear regression analysis results are shown in Table 3. Ambient PM2.5 mass concentrations explained >80% variance of the indoor counterparts (Table 3). In addition, the variance explained by the ambient PM2.5 data over the 24-h sampling period (91%) was higher than that explained by the hourly real-time data (84%). The difference was reasonable, because the hourly indoor data were more sensitive to indoor PM2.5 concentration spikes due to emissions from indoor sources than the average data over the 24-h sampling period. Similar to the Pearson correlation analysis, excluding the smoking families did not significantly change the linear regression analysis results as well (Table 3). As stated earlier, there were 8 residences in our study, in which indoor and ambient PM2.5 mass concentrations did not strongly correlate with each other. The variance of indoor PM2.5 mass concentrations explained by ambient counterpart was ≤ 60% for the 8 residences, while it was ≥65% for the remaining residences (data not shown here).

thumbnail
Table 3. Regression analysis of indoor and ambient PM2.5 mass concentrations.

https://doi.org/10.1371/journal.pone.0138559.t003

The slopes in the indoor-ambient PM2.5 regression models can be the estimates of the infiltration factors of ambient PM2.5 (Finf)[25, 27], whereas the intercepts can be the estimates of the concentrations of indoor PM2.5 generated by indoor sources[25, 27]. The values of Finf, which represented the fraction of infiltrated ambient PM2.5 that remained suspended[25], were 0.67–0.73 on the community basis (Table 3); whereas the Finf of single residences largely varied from 0.18 to 0.90. The modeling analyses yielded negative intercepts (p<0.05, Table 3). The negative estimates implied that particles of indoor origin only accounted for a small fraction of residential indoor PM2.5 compared to that infiltrated from outdoors. On the other hand, there may be significant sink of infiltrated ambient PM2.5 in the indoor spaces. According to a balance-point concept developed by Li and Chen[45], a balance-point outdoor PM2.5 concentration is present for a given indoor microenvironment [45]. When outdoor PM2.5 concentration equals the balance-point one, a balance state is reached between indoor particle generation speed and particle deposition rate, under which I/A of PM2.5 equals penetration efficiency [45]. When outdoor concentration exceeds the balance-point outdoor value, I/A is lower than penetration efficiency, implying net decay of infiltrated PM2.5. The ambient PM2.5 concentrations were generally higher than the balance-point value under the distinctive high ambient fine particle pollution in Beijing, and the net decay (sink) of infiltrated PM2.5 was expected. The net decay of infiltrated PM2.5 resulted in the lower I/A ratio in our tests, the mean and median of which were 0.63 and 0.62, respectively.

The indoor/ambient ratio (I/A) of PM2.5 mass concentration is another important indicator of indoor-outdoor relationship of PM2.5. A high I/A is usually associated with significant indoor PM2.5 sources. Thus, I/A can be used to examine the impacts of indoor sources on indoor PM2.5 mass concentrations. As shown in Table 1, the mean I/A over the 24-h sampling period was 0.63±0.15 with median of 0.62. Peaks of I/A were found at 12:00–13:00 and 23:00–0:00 (Fig 2), suggesting the presence of significant indoor PM2.5 sources in the two time intervals. In addition, slight increase of I/A can be discerned in early morning (7:00–9:00) and evening (15:00–17:00) (Fig 2).

Predictive models of indoor and ambient PM2.5 mass concentrations

In this study, the OLS method was utilized to examine the associations between a variety of factors and PM2.5 mass concentrations.

The variables considered for the predictive model of ambient PM2.5 mass concentrations were ambient criteria air pollutant concentrations. The results, which are presented in Table 4, indicated that ambient PM2.5 concentrations were positively associated (p<0.05) with the concentrations of ambient O3, NO2 and SO2. The three pollutants contributed to 7.4% of total variance of ambient PM2.5 mass concentrations.

thumbnail
Table 4. Predictive model of ambient PM2.5 mass concentrations.

https://doi.org/10.1371/journal.pone.0138559.t004

The variables considered for the model of indoor PM2.5 mass concentrations were subject to built environment, human behavior and chemistry. As shown in Table 5, there were 10 variables entering the predictive model of all families. The predictive model explained 41.1% of total variance. The variable having the maximum variance contribution was number of occupants (21.5% of total variance and thereafter), followed by ambient SO2 (7.7%), ambient O3 (2.8%) and ambient NO2 (1.9%). The variables subject to lifestyle and built environment had relatively small variance contribution (Table 5).

thumbnail
Table 5. Predictive model of indoor PM2.5 mass concentrations.

https://doi.org/10.1371/journal.pone.0138559.t005

The predictive model of the non-smoking families was presented in Table 5 as well. The model explained 42.4% of total variance. Compared to the model of all families, the variables, traffic route and cooking, were included in the model, while the variable, frequency of furniture cleaning, was not included. The variable having the maximum variance contribution was still number of occupants (28.6%), followed by ambient SO2 (7.9%), traffic route (3.0%), indoor plants (0.7%), frequency of floor cleaning (0.7%), floor cleaning method (0.5%), ambient O3 (0.4%), ambient NO2 (0.3%), distance to the road (0.3%) and cooking (0.2%).

Discussion

The mean ambient PM2.5 concentration over 24-h period in Beijing was 69 μg/m3 in this study; while the counterpart in the North American metropolitan areas such as Los Angeles, Boston and Toronto were as low as 25, 14 and 28 μg/m3, respectively [30, 46, 47]. Additionally, the outdoor PM2.5 mass concentrations over 24-h or 48-h period in several large-scale studies such as the RIOPA and EXPOLIS were reported to be 14–21 and 10–40 μg/m3, respectively [21, 33]. It can be seen that the ambient PM2.5 mass concentrations in Beijing were much higher than those in the US and Europe. The sampling was conducted from July to September, during which the windows were open most of time. Given such, ambient PM2.5 may strongly influence residential indoor PM2.5 under the high ambient fine particle pollution conditions. This statement is supported by the Pearson correlation analysis results, which showed significantly strong (r≥0.90) and positive correlation between ambient and indoor PM2.5 data. The strong impact of ambient PM2.5 on the indoor counterpart is also demonstrated by the regression analysis results, which showed that ambient PM2.5 mass concentration data contributed >80% total variance of indoor PM2.5 data. The results also implied that PM2.5 of indoor origin only accounted for a small fraction of indoor PM2.5 in this study. According to these results, PM2.5 of ambient origin made dominant contribution to residential indoor PM2.5 exposure in the non-heating season. The synchronous diurnal variation of ambient and indoor PM2.5 mass concentrations was thus within expectation as well. The dominant contribution of ambient PM2.5 does not necessarily mean that it was reasonable to use ambient PM2.5 mass concentration as the surrogate of residential indoor PM2.5 exposure in the non-heating season. The inter-residence variability of Finf values indicated that the infiltration efficiency of ambient PM2.5 largely varied by dwellings. As a result, the use of ambient PM2.5 mass concentrations as the exposure surrogates can lead to significant exposure misclassification.

The diurnal variation pattern of ambient PM2.5 mass concentrations in our study was very similar to that observed in Windsor, Canada (referred as the Windsor study and thereafter)[39]. The similarity implies sharing mechanisms underlying ambient PM2.5 mass concentration variation in the two studies. The morning increase of ambient PM2.5 concentrations (5:00–8:00) was attributed to heavy traffic emission in the morning “rush” hours (Fig 2). The morning increase was also observed in the Windsor study [39] and the retirement homes in Los Angeles Basin (referred as the Los Angeles study and thereafter)[30]. The falling ambient PM2.5 concentrations in 10:00–17:00 were accompanied with substantially increasing ambient O3 concentrations (Fig 2). The substantially increasing O3 concentrations in ambient air resulted from the intense photochemical reactions in the summer. The intense photochemical reactions promote formation of secondary particulate matter in ambient PM[30], which are usually in ultrafine size bins[20, 39]. Several studies have observed substantially increased concentrations of ambient ultrafine PM (UFP) in the afternoon [20, 39]. However, UFP only have small contribution to PM2.5 mass concentrations. As a result, the increased ambient O3 concentrations in the afternoon did not lead to increasing ambient PM2.5 mass concentrations in our tests as well as the Windsor and Los Angeles studies[30, 39]. The evening increase of ambient PM2.5 concentrations was possibly driven by two mechanisms: a) heavy traffic emission in the evening “rush” hours; b) a lower mixing height in atmosphere, which does not favor diffusion and dispersion of air pollutants [30]. The lower mixing height in atmosphere resulted in the higher concentrations at 21:00–3:00, and the elevating mixing height since 3:00 was the likely cause of the slight concentration decrease in 3:00–5:00. The higher mixing height resulted in the lower concentrations in the late morning and afternoon.

There was noticeable increase of I/A at 23:00–0:00, indicating the presence of significant indoor PM2.5 sources at this time interval. The increase was likely due to intensive indoor human activities in the evening, when there were maximum occupants indoors. We acknowledge that these activities could not be identified from the questionnaires. Intensive indoor human activities, such as cooking, were one of the probable factors leading to the noticeable increase of I/A at 11:00–13:00. Indoor human activities, such as cooking and indoor cleaning, may contribute to the slight increase of I/A at 7:00–9:00 and 15:00–17:00. Another likely contributor of the slight increase at 7:00–9:00 was fresh traffic emission. The fresh traffic emission in the morning rush hours resulted in higher elemental carbon (EC) concentrations in atmosphere and smaller size distribution[22, 30]. The outdoor-to-indoor infiltration during this period was expected to higher, and thus a slight increase of I/A was within expectation.

The predictive models in this study can help characterizing possible sources of airborne particles. It is known that gas-phase oxidation of ambient SO2 and NO2 induced by atmospheric hydroxyl radical produces sulfate and nitrate particles, which are in accumulation mode [31, 44]. Ambient O3 are associated with the formation of secondary organic carbons in accumulation mode, because both are products of photochemical reactions in atmosphere [44]; whereas O3 can also contribute to formation of secondary organic carbons [35, 48]. It is thus reasonable that ambient PM2.5 mass concentrations were positively associated with the concentrations of ambient SO2, NO2 and O3. The associations suggested the contribution of secondary inorganic and organic aerosols to ambient PM2.5.

The concentrations of ambient SO2, NO2 and O3 were also positively associated with the indoor PM2.5 concentrations (Table 5). The associations implied the significant contribution of secondary aerosols to indoor PM2.5. The secondary aerosols included those infiltrated from outdoors, and also included those formed indoors via O3-terpene reactions [35, 48]. The associations between distance to traffic road and indoor PM2.5 mass concentrations (Table 5) suggested that aerosols related to traffic emission contributed to indoor PM2.5 and the influence was distance dependent. It is necessary to note that the actual association between indoor PM2.5 mass concentration and distance to the road was not linear relationship. In the companion article studying the determinants on infiltration efficiency of ambient PM2.5, we found that the infiltration efficiency reached highest within the 2nd quartile distance and lowest within the 4th quartile distance during our field tests. The variable, proximate traffic route type, entered the model of non-smoking families (Table 5). A higher indoor PM2.5 concentration was associated with the buildings proximate to arterial road (ring roads), and a lower concentration was associated with the buildings proximate to quiet street. The results are reasonable given that the traffic emission was stronger in the arterial roads than in the quiet streets.

The variance of indoor PM2.5 data that remained unexplained by ambient PM2.5 indicated the potential implication of indoor PM2.5 sources. The predictive models of indoor PM2.5 mass concentrations characterized some of these sources. Indoor plants could contribute to indoor PM2.5 through resuspension of soil particles and formation of secondary submicron particles via ozone-biogenic terpenes reactions [35, 48]. Thus, more plants in residential indoor spaces was found to result in higher indoor PM2.5 mass concentrations in our study (Table 5).

As earlier discussed, ambient PM2.5 mass concentrations were generally higher than the balance-point values under the distinctive ambient fine particle pollution conditions. As a result, significant sink (net decay) of infiltrated ambient PM2.5 was expected in our study. The fine particles can deposit on various indoor surfaces. Indoor cleaning activities can lead to resuspension of particles [37, 38]. Therefore, the variables such as frequency of furniture cleaning, frequency of floor cleaning and floor cleaning method in this study were found to be the predictors of indoor PM2.5 concentrations. Note that the OLS analysis showed different relationship patterns for frequency of floor cleaning and frequency of furniture cleaning. Less frequently the occupants cleaned the floor, higher the indoor PM2.5 concentrations were, and it was reverse for the influence of furniture cleaning frequency. The mechanisms driving the differences are not clear. Moreover, indoor PM2.5 mass concentrations were higher in the residences where occupants cleaned floor with mop and broom/vacuum than in those where occupants cleaned floor with mop only. It is within expectation because cleaning with broom or vacuum can lead to more resuspension of particles.

Smoking was identified as another indoor PM source in this study. As shown in the predictive model of all families (Table 5), the indoor PM2.5 concentrations were higher in the residences where smoking activities occurred for at least one time. It is interesting that cooking was only found to be an identified indoor PM2.5 source in the non-smoking families (Table 5). In addition, cooking activities did not lead to sharp increase of I/A in our field tests. The results suggested that the associations between cooking and indoor PM2.5 mass concentrations were not as strong as those of other factors. One possible reason is that occupants turned on the hood and possibly isolated kitchen microenvironment with other spaces in residence via closing doors when cooking. Another possible reason is that particles generated by cooking are mainly in ultrafine size bins[39], which only account for small fraction of PM2.5 mass concentration.

The variable, number of occupants, had greater contribution to total variance of indoor PM2.5 data than other variables. A higher number of occupants indoors are usually associated with more intensive human activities indoors. More intensive human activities could generate more indoor fine particles. Nonetheless, the specific human activities indoors that generated PM2.5 were not clear. These activities may include, but not limited to, the activities related to the other variables in the predictive model.

Conclusions and Recommendation

Ambient and residential indoor PM2.5 mass concentrations were concurrently collected for 41 residences in urban area of Beijing in the non-heating season. Ambient PM2.5 mass concentrations in Beijing were much higher than those in other metropolitan areas in the US and Europe. The high ambient fine particle pollution condition resulted in the following observations in this study: a) the median indoor/ambient ratio of PM2.5 mass concentration was as low as 0.63; b) ambient and residential indoor PM2.5 concentrations highly correlated with each other; c) ambient PM2.5 mass concentrations explained >80% total variance of indoor data. According to the results, ambient PM2.5 dominated residential indoor exposure to PM2.5 in the non-heating season on the community basis. However, it is still not reasonable to use ambient PM2.5 mass concentrations as the exposure surrogates in non-heating season, given the large inter-residence variability of infiltration efficiency of ambient PM2.5. On the other hand, PM2.5 of indoor origin still had minor influence on indoor PM2.5 mass concentrations. Noticeable indoor PM2.5 sources were identified at 11:00–13:00 and 22:00–0:00. The predictive models suggested that particles from traffic emission, secondary aerosols, particles from indoor smoking, suspended particles due to indoor cleaning and particles related to indoor plants contributed to indoor PM2.5 mass concentrations in this study.

The hourly real-time PM2.5 mass concentration data were collected in this study. The data were subsequently used to characterize the diurnal variation of ambient and indoor PM2.5 mass concentrations, in an effort to identify the time intervals in which there were significant indoor PM2.5 sources. On the other hand, emissions of many indoor sources, such as smoking, cooking and cleaning, are instantaneous or last for a short period. Emissions of these sources can influence indoor PM2.5 concentrations via generation of concentration spikes. However, the impacts of concentration spikes cannot be fully reflected in the diurnal variation pattern characterized by the hourly data. It is thus recommended to use data of higher time resolution in the future, which can favor characterizing the influence of indoor sources on indoor PM2.5 mass concentrations.

There is a delay period before equilibrium is reached between indoor PM2.5 and the infiltrated fraction. The delay period can be influenced by a variety of factors, an important of which is ventilation condition. The ventilation condition is an important determinant on the indoor-ambient relationship of PM2.5 mass concentrations. However, the real-time hourly ventilation rates of the tested residences were not measured in this study. As a result, we did not characterize the influence of ventilation condition on the indoor-ambient relationship. This is another major limitation of this study.

Real-time ventilation condition is a sophisticated function of many variables subject to building materials, building envelope structure, interior layout and human activities, so does the indoor-ambient relationship of PM2.5 mass concentrations. Nevertheless, only limited variables were considered in this study. The very incompleteness led to ~60% variance of indoor PM2.5 data that remained unexplained by the predictive models. On the other hand, we found 8 residences in this study, where indoor and ambient PM2.5 mass concentrations had weak correlation with each other. The regression analysis results suggested that there were potential strong indoor PM2.5 sources in these residences. However, any human activities related to the potential indoor PM2.5 sources could not be identified through the questionnaire. Given such, improvement of the questionnaire is recommended for the prospective similar study.

It is found that the indoor PM2.5 mass concentrations were associated with the distance to road in this study. The association resulted from the alteration of PM properties during aging and transport, such as size distribution and PM speciation. The property alteration can influence the infiltration behavior of ambient PM2.5, and thus influence the I/A. Therefore, size distribution and PM speciation can be more straightforward predictors of I/A. However, we did not collect PM properties in this study. It is recommended that PM properties are measured in the future and are used to build up relevant predictive models for indoor and ambient PM2.5 mass concentrations. The results may greatly contribute to the knowledge of residential indoor exposure to ambient PM2.5.

Moreover, Beijing has four distinctive seasons, and meteorological conditions, urban ambient pollution and human activity pattern dramatically differ in the heating and non-heating seasons. Thus, it is recommended to study the indoor-outdoor relationship of PM2.5 mass concentrations in the heating season as part of fine particle exposure assessment.

Supporting Information

S1 File. Table A- Residence locations and nearest environmental quality monitoring stations (EQM); Table B- Comparison of hourly ambient PM2.5 mass concentrations provided by EQM and measured by the light-scattering devices in our study; Fig A- Tests of normal distribution hypotheses for ambient PM2.5 data; Fig B- Tests of normal distribution hypotheses for indoor PM2.5 data; Fig C- Tests of normal distribution hypotheses for ambient O3 data; Fig D- Tests of normal distribution hypotheses for ambient NO2 data; Fig E- Tests of normal distribution hypotheses for ambient SO2 data.

https://doi.org/10.1371/journal.pone.0138559.s001

(DOCX)

Acknowledgments

We would like to thank and acknowledge the help of all of our study participants for allowing us to make the measurements in their homes. This study is supported by Natural Science Foundation of China (41172212, 41230314), and Chinese Postdoctoral Science Foundation (2014M550739).

Author Contributions

Conceived and designed the experiments: LH. Performed the experiments: LH ZP ML. Analyzed the data: LH. Contributed reagents/materials/analysis tools: LH ZP. Wrote the paper: LH JS.

References

  1. 1. Nel A (2005) Air pollution-related illness: Effects of particles. Science 308: 804–806. pmid:15879201
  2. 2. Chow JC, Watson JG, Mauderly JL, Costa DL, Wyzga RE, Vedal S, et al. (2006) Health effects of fine particulate air pollution: Lines that connect. Journal of the Air & Waste Management Association 56: 1368–1380.
  3. 3. Analitis A, Katsouyanni K, Dimakopoulou K, Samoli E, Nikoloulopoulos AK, Petasakis Y, et al. (2006) Short-term effects of ambient particles on cardiovascular and respiratory mortality. Epidemiology 17, (2): 230–233. pmid:16477266
  4. 4. Atkinson RW, Carey IM, Kent AJ, van Staa TP, Anderson HR, Cook DG. (2013) Long-Term Exposure to Outdoor Air Pollution and Incidence of Cardiovascular Diseases. Epidemiology 24, (1): 44–53. pmid:23222514
  5. 5. Boezen HM, van der Zee SC, Postma DS, Vonk JM, Gerritsen J, Hoek G, et al. (1999) Effects of ambient air pollution on upper and lower respiratory symptoms and peak expiratory flow in children. Lancet 353, (9156): 874–878. pmid:10093979
  6. 6. Fairley D (1999) Daily mortality and air pollution in Santa Clara County, California: 1989–1996. Environmental Health Perspectives 107, (8): 637–641. pmid:10417361
  7. 7. Gotschi T, Heinrich J, Sunyer J, Kunzli N (2008) Long-term effects of ambient air pollution on lung function—A review. Epidemiology 19, (5): 690–701. pmid:18703932
  8. 8. Koken PJM, Piver WT, Ye F, Elixhauser A, Olsen LM, Portier CJ (2003) Temperature, air pollution, and hospitalization for cardiovascular diseases among elderly people in Denver. Environmental Health Perspectives 111, (10): 1312–1317. pmid:12896852
  9. 9. Linn WS, Szlachcic Y, Gong H, Kinney PL, Berhane KT (2000) Air pollution and daily hospital admissions in metropolitan Los Angeles. Environmental Health Perspectives 108, (5): 427–434. pmid:10811569
  10. 10. Mann JK, Balmes JR, Bruckner TA, Mortimer KM, Margolis HG, Pratt B, et al. (2010) Short-Term Effects of Air Pollution on Wheeze in Asthmatic Children in Fresno, California. Environmental Health Perspectives 118, (10): 1497–1502. pmid:20570778
  11. 11. Weichenthal S, Kulka R, Dubeau A, Martin C, Wang D, Dales R (2011) Traffic-Related Air Pollution and Acute Changes in Heart Rate Variability and Respiratory Function in Urban Cyclists. Environmental Health Perspectives 119, (10): 1373–1378. pmid:21672679
  12. 12. Rich DQ, Kipen HM, Huang W, Wang GF, Zhu P, Ohman-Strickland P, et al. (2012) Association Between Changes in Air Pollution Levels During the Beijing Olympics and Biomarkers of Inflammation and Thrombosis in Healthy Young Adults. Jama-Journal of the American Medical Association 307(19): 2068–2078.
  13. 13. Bell ML, Ebisu K, Belanger K (2007) Ambient air pollution and low birth weight in Connecticut and Massachusetts. Environmental Health Perspectives 115, (7): 1118–1124. pmid:17637932
  14. 14. Chang HH, Reich BJ, Miranda ML (2012) Time-to-Event Analysis of Fine Particle Air Pollution and Preterm Birth: Results From North Carolina, 2001–2005. American Journal of Epidemiology, 175(2): 91–98. pmid:22167746
  15. 15. Wang CC, Zhou XD, Chen RJ, Duan XL, Kuang XY, Kan HD (2013) Estimation of the effects of ambient air pollution on life expectancy of urban residents in China. Atmospheric Environment 80: 347–351.
  16. 16. Dong GH, Qian ZM, Wang J, Chen WQ, Ma WJ, Trevathan E, et al. (2013) Associations between ambient air pollution and prevalence of stroke and cardiovascular diseases in 33 Chinese communities. Atmospheric Environment 77: 968–973.
  17. 17. Zhang YJ, Guo YM, Li GX, Zhou J, Jin XB, Wang WY, et al. (2012) The spatial characteristics of ambient particulate matter and daily mortality in the urban area of Beijing, China. Science of the Total Environment 435: 14–20. pmid:22846759
  18. 18. Department of Social, Science and Technology Statistics, National Bureau of Statistics (2010) Time Use Patterns in China. Beijing: China Statistics Press
  19. 19. Chen C and Zhao B (2011) Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor. Atmospheric Environment, 45(2): 275–288.
  20. 20. Wang YG, Hopke PK, Chalupa DC, Utell MJ (2010) Long-Term Characterization of Indoor and Outdoor Ultrafine Particles at a Commercial Building. Environmental Science & Technology 44(15): 5775–5780.
  21. 21. Meng QY, Turpin BJ, Korn L, Weisel CP, Morandi M, Colome S, et al. (2005) Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations: Analyses of RIOPA data. Journal of Exposure Analysis and Environmental Epidemiology, 15(1): 17–28. pmid:15138449
  22. 22. Hodas N, Meng QY, Lunden MM, Rich DQ, Ozkaynak H, Baxter LK, et al. (2012) Variability in the fraction of ambient fine particulate matter found indoors and observed heterogeneity in health effect estimates. Journal of Exposure Science and Environmental Epidemiology 22(5): 448–454. pmid:22617722
  23. 23. Meng QY, Turpin BJ, Lee JH, Polidori A, Weisel CP, Morandi M, et al. (2007) How does infiltration behavior modify the composition of ambient PM2.5 in indoor spaces? An analysis of RIOPA data. Environmental Science & Technology 41(21): 7315–7321.
  24. 24. Sarnat SE, Coull BA, Ruiz PA, Koutrakis P, Suh HH (2006) The influences of ambient particle composition and size on particle infiltration in Los Angeles, CA, residences. Journal of the Air & Waste Management Association, 56(2): 186–196.
  25. 25. Diapouli E, Chaloulakou A and Koutrakis P (2013) Estimating the concentration of indoor particles of outdoor origin: A review. Journal of the Air & Waste Management Association, 63(10): 1113–1129.
  26. 26. Long CM, Suh HH, Catalano PJ, Koutrakis P (2001) Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior. Environmental Science & Technology, 35(10): 2089–2099.
  27. 27. Meng QY, Turpin BJ, Polidori A, Lee JH, Weisel C, Morandi M, et al. (2005) PM2.5 of ambient origin: Estimates and exposure errors relevant to PM epidemiology. Environmental Science & Technology 39, (14): 5105–5112.
  28. 28. Wichmann J, Lind T, Nilsson MA, Bellander T (2010) PM2.5, soot and NO2 indoor-outdoor relationships at homes, pre-schools and schools in Stockholm, Sweden. Atmospheric Environment, 44(36): 4536–4544.
  29. 29. Allen R, Larson T, Sheppard L, Wallace L, Liu LJS (2003) Use of real-time light scattering data to estimate the contribution of infiltrated and indoor-generated particles to indoor air. Environmental Science & Technology, 37(16): 3484–3492.
  30. 30. Polidori A, Arhami M, Sioutas C, Delfino RJ, Allen R (2007) Indoor/outdoor relationships, trends, and carbonaceous content of fine particulate matter in retirement homes of the Los Angeles basin. Journal of the Air & Waste Management Association 57(3): 366–379.
  31. 31. Sarnat JA, Long CM, Koutrakis P, Coull BA, Schwartz J, Suh HH (2002) Using sulfur as a tracer of outdoor fine particulate matter. Environmental Science & Technology 36(24): 5305–5314.
  32. 32. Hanninen OO, Lebret E, Ilacqua V, Katsouyanni K, Kunzli F, Sram RJ, et al. (2004) Infiltration of ambient PM2.5 and levels of indoor generated non-ETS PM2.5 in residences of four European cities. Atmospheric Environment,. 38(37): 6411–6423.
  33. 33. Gotschi T, Oglesby L, Mathys P, Monn C, Manalis N, Koistinen K, et al. (2002) Comparison of black smoke and PM2.5 levels in indoor and outdoor environments of four European cities. Environmental Science & Technology 36(6): 1191–1197.
  34. 34. Wainman T, Zhang JF, Weschler CJ, Lioy PJ (2000) Ozone and Limonene in Indoor Air: A Source of Submicron Particle Exposure. Environmental Health Perspectives, 108(12): 1139–1145. pmid:11133393
  35. 35. Calogirou A, Larsen BR, Kotzias D (1999) Gas-phase terpene oxidation products: a review. Atmospheric Environment, 33: 1423–1439.
  36. 36. Levy JI, Bennett DH, Melly SJ, Splengler JD (2003) Influence of traffic patterns on particulate matter and polycyclic aromatic hydrocarbon concentrations in Roxbury, Massachusetts. Journal of Exposure Analysis and Environmental Epidemiology,. 13(5): 364–371. pmid:12973364
  37. 37. Qian J, Ferro AR (2008) Resuspension of dust particles in a chamber and associated environmental factors. Aerosol Science and Technology 42(7): 566–578.
  38. 38. Qian J, Ferro AR, Fowler KR (2008) Estimating the resuspension rate and residence time of indoor particles. Journal of the Air & Waste Management Association 58(4): 502–516.
  39. 39. Wheeler AJ, Wallace LA, Kearney J, Van Ryswyk K, You HY, Kulka R, et al. (2011) Personal, Indoor, and Outdoor Concentrations of Fine and Ultrafine Particles Using Continuous Monitors in Multiple Residences. Aerosol Science and Technology, 45(9): 1078–1089.
  40. 40. Gwynn RC, Burnett RT, Thurston GD (2000) A time-series analysis of acidic particulate matter and daily mortality and morbidity in the Buffalo, New York, Region. Environmental Health Perspectives,. 108(2): 125–133. pmid:10656852
  41. 41. Ito K, Thurston GD and Silverman RM (2008) Characterization of PM2.5, gaseous pollutants and meteorological interactions in the context of time-series health effects models. Journal of Exposure Science and Environmental Epidemiology,. 17(Suppl 2): S45–60.
  42. 42. Kousa A, Oglesby L, Koistinen K, Kunzli N, Jantunen M (2002) Exposure chain of urban air PM2.5—associations between ambient fixed site, residential outdoor, indoor, workplace and personal exposures in four European cities in the EXPOLIS-study. Atmospheric Environment, 36(18): 3031–3039.
  43. 43. Williams R, Creason J, Zweidinger R, Watts R, Sheldon L, Shy C (2000) Indoor, outdoor, and personal exposure monitoring of particulate air pollution: the Baltimore elderly epidemiology-exposure pilot study. Atmospheric Environment, 34(24): 4193–4204.
  44. 44. Finlayson-Pitts BJ, James N. Pitts J (1986) Atmospheric Chemistry: Fundamentals and Experimental Techniques. New York: John Wiley & Sons.
  45. 45. Li YG, Chen ZD (2003) A balance-point method for assessing the effect of natural ventilation on indoor particle concentrations. Atmospheric Environment 37, (30): 4277–4285.
  46. 46. Pellizzari ED, Clayton CA, Rodes CE, Mason RE, Piper LL, Fort B, et al. (1999) Particulate matter and manganese exposures in Toronto, Canada. Atmospheric Environment 33(5): 721–734.
  47. 47. Long CM, Sarnat JA (2004) Indoor-outdoor relationships and infiltration behavior of elemental components of outdoor PM2.5 for Boston-area homes. Aerosol Science and Technology 38: 91–104.
  48. 48. Fan ZH, Lioy P, Weschler C, Fiedler N, Kipen H, Zhang JF (2003) Ozone-Initiated Reactions with Mixtures of Volatile Organic Compounds under Simulated Indoor Conditions. Environ. Sci. Technol. 37: 1811–1821. pmid:12775052